background image

 

6.2  Water heater (Boiler) 

The slot in heat pump WP2-AE is designed for water heaters with a standard flange 
(Φ180 mm/8 hole). It is to be instaled on the side of the water heater. 

6.3  Aditional electrical heater  

Additional electric heater EG with power 1.3 kW is used for:  

-

 

quick heating of the tap water

 - simultaneous operation of the heat pump 

and the electric heater. 

-

 

protecting the evaporator - 

if the ambient temperature is too low to allow 

the  operation  of  the  heat  pump,  the  additional  heater  is  automatically 
switched on when the pump operates in summer mode of operation. 

-

 

alternative heating -

 e.g. in case of malfunction of the aggregate. 

6.4  Safety elements of the heat pump 

Temperature feeler – protection against freezing 

The  heat  pump  incorporates  a  temperature  feeler  which  is  used  to  detect  the 
temperature  of  the  air  flowing  through  the  pump.  In  case  the  air  temperature  is 
below 7°C, the feeler switches off the operation of the pump for 30 minutes. With 
heat pumps operating  with an electric heater and summer mode of operation, the 
pump  automatically  switches  on  heating  as  soon  as  the  air  temperature  drops 
below 7°C. When this air temperature is reached in winter mode of operation, the 
circulating pump of the connected oil fired boiler is switched on.

 

 

Operating and safety thermostat of electric heater (only WPA 302 E-LF) 

The electric heater incorporates an operating and safety thermostat limited to 65°C. 

Caution!

 When the electric heater operates, the water is always heated to approx. 

65°C, since only the upper part of the hot water tank is heated. In such case, the 
regulator does not display the actual water temperature, since the feeler is installed 
in the bottom part of the hot water tank where the water temperature is lower.

 

 

Temperature control in the hot water tank 

The  OPTITRONIC  regulator  is  installed  in  the  heat  pump  to  provide  control  and 
heating of water to desired temperature. 
Taking into account the selected water temperature, the regulator switches on and 
off  the  operation  of  the  compressor  and  the  fan.  Under  specific  conditions,  the 
regulator also switches on and off the electric heater or the circulating pump of the 
oil fired boiler. The maximum adjustable water temperature is 55°C. After pressing 
the 'HT' key, the water temperature rises to 60°C (overheating). 

 

 

High pressure protection of the refrigerating system 

In  order  to  prevent  high  pressure  in  the  refrigerating  system  and  subsequently 
damage to the compressor, a high pressure safety switch is installed to emergency 
switch  off  the  operation  of  the  heat  pump  in  case  of  high  pressure.  When  the 
pressure in the refrigerating system drops, the heat pump is automatically switched 
back on.

 

Содержание WP2 -

Страница 1: ...HEAT PUMP WP2 AE Type WP2 Model WP2 AE INSTRUCTIONS FOR INSTALLATION AND USE Includes Declaration of Warranty Kundendienst ...

Страница 2: ... TANK 7 7 FILLING THE WATER IN THE SYSTEM 7 7 1 CONDENSATE OUTLET 7 7 2 CONNECTION TO ELECTRICITY SUPPLY NETWORK 7 7 3 ELEKTRISCHER SCHALTPLAN 8 7 4 GROUNDING CABEL INSTALATION 8 7 5 HEAT PUMP START UP 9 7 5 1 Operating procedure 10 7 5 2 Short instructions for operation 11 7 5 3 Operating programmes 13 7 5 4 Paramter display 13 8 HEAT PUMP INSTALATION SITE 14 9 SAFETY WARNINGS 15 10 INSTRUCTIONS ...

Страница 3: ...ure you enclose the Instructions for use Read the Instructions carefully and make sure you completely understand the sections and paragraphs marked with this sign This sign is used in the text to point out that the related part of the Instructions is especially important In addition this sign is also used with other markings symbols and warning signs as to remind you to pay attention 3 Customer se...

Страница 4: ...rantee for safe and functional operation of the product The manufacturer shall not be liable for or assume any responsibility in case of incorrect use or use for purpose other than intended and the customer shall be solely responsible for any such damage resulting from incorrect use or use for purpose other than intended 5 Specifications Produkt HEAT PUMP FOR TAP WATER HEATING Type WP2 Model WP2 A...

Страница 5: ... where the thermodynamic process for the hot tap watter heating happens Dimensions Model Min Volume Dimensions HxWxT T1xA Total weight WP2 AE 140 880x470x330 490x250 35 kg 6 1 Refrigerant circuit Functional principle of the heat pump The refrigerant circuit is a closed system in which the R134a refrigerant circulates used as a heat transfer media In the fin exchanger the heat is removed from the i...

Страница 6: ...red boiler is switched on Operating and safety thermostat of electric heater only WPA 302 E LF The electric heater incorporates an operating and safety thermostat limited to 65 C Caution When the electric heater operates the water is always heated to approx 65 C since only the upper part of the hot water tank is heated In such case the regulator does not display the actual water temperature since ...

Страница 7: ... water and deaeration is complete Do not let the pump operate with empty hot water tank danger of damaging the compressor 7 1 Condensate outlet Due to the humidity of the air condensate is formed in the heat pump Depending on the season and hot water demand 1 to 5 litres of condensate per day is accumulated This condensate water can be used for steam ironing or for watering the plants To drain off...

Страница 8: ...ation Die Erdung des Boilers muss über einen Erdungsgewindebolzen erfolgen High pressure switch Water temperature probe T1 Ambent air temperature probe T2 Heater 230 V AC 50Hz Compressor Fan Heat pump flange Seal housing Condensate outlet Hot water tank flange Rack washer Heat pump flange Grounding washer Bolt M12x40 ...

Страница 9: ...case that the resistance is not in the renge specified above the grounding assemblly hast o be checked 7 5 Heat pump start up Up to date and efficient visual transmission of information on operation of the system via display and control lamps Quick keys for water temperature adjustment Quick key for switching between operating modes P Quick key HT for single superheating of water to 60 c legionell...

Страница 10: ...switches on When the preset switch off temperature of 52 C is reached the heat pump switches off automatically As soon as water temperature drops by 5 C i e to 47 C the heat pump starts operating again The user may at his own discretion adjust the switch off temperature but not higher than 55 C thermostat lock Heating the water to 60 C is limited by factory setting and cannot be adjusted The ambie...

Страница 11: ...splayed but the water is further heated off off P3 The water is heated to the set temperature by an electric heater Note Air temperature has no effect on the function blinks on P5 The heat pump heats the water to the set temperature with the compressor automatic operation mode The heat pump heats the water depending on the air temperature If the temperature drops below the switching level the heat...

Страница 12: ... P key see table above With every subsequent pressing of the P key within 8 seconds you can switch between the available operating modes TIP In case that temperature in the room is higher than 7 C it is the most cost effective to heat the water exclusively with the heat pump P1 P4 P5 3 Single thermal disinfection Single overheating of water to 60 C is switched on with the HT key the indicator lamp...

Страница 13: ...he automatic switching to the backup heating source in case of undercooling of the air the P5 programme only The heat pump operates completely automatically with the priority of the compressor operation until the set temperature is reached and as long as the air temperature is above the switching off level L1 When the air temperature drops below the switching off level the device automatically swi...

Страница 14: ...nu press the keys and simultaneously Use these keys to scroll between the functions in the menu Select the parameter L1 and after a few seconds the preset switch off temperature appears factory set to 7 C While the set temperature is displayed it can be changed by pressing the keys or from 5 to 25 C 5 seconds after the desired setting is selected the blinking stops and the setting is saved It is n...

Страница 15: ...onnel with knowledge of safety instruction and instructions for use and maintenance should manipulate with this product Do not move clean or repair the product during operation Before installation and any other intervention inside the heat pump make sure you read the instructions for safe use and maintenance The electrical installation of the device must be carried out by a qualified person an aut...

Страница 16: ... maintenance We recommend you check the following Check the operation of the safety valve on the cold water tap unscrew the cap on the tap until the water starts dripping Check of the evaporator fins dust deposit on the fins will reduce the efficiency of the heat pump In case of dust deposit of the fins disconnect the heat pump from power supply loosen the screws remove the top plastic cover and c...

Страница 17: ...each up to max 55 C NEVER PLACE THE HEAT PUMP IN A HORIZONTAL POSITION 12 Dismantling and disposal The device as a whole has according to its technical concept an operational life of several years Individual component parts have different life cycles and they should be replaced with new ones after they are malfunctioned damaged or worn Replace them exclusively with original replacement parts When ...

Страница 18: ...f the product the following warning signs had been used to mark potential hazards The warning signs have the following meaning Be sure to read the instructions Danger Electricity Do not place in horizontal position Transport and operation in vertical position Besides symbols and warning signs the device also has an attached plate or sticker containing its specifications ...

Страница 19: ...em is too high Check if there is sufficient water in the tank Delete the warning with key In case of repeated malfunction call the authorised servicing centre Alternating E8 and Temperature feeler for water is not connected Check if the feeler is connected or call the authorised servicing centre Alternating E8 and _ _ Temperature feeler for water is malfunctioned First reset the heat pump Check th...

Страница 20: ... of heat from the hot water tank too large consumption of hot water Check all possible points for heat escape from the hot water tank Too much noise during operation of the pump Ice formation on the evaporator The fan is in contact with the pump housing or protective net Call the authorised servicing centre Check the air intake and outlet Damaged compressor damaged fixing springs Air flow rate is ...

Страница 21: ...g instructions Operating and Installation Instructions damages due to external influences connection to the wrong voltage corrosion damage as a consequence of aggressive waters water not suitable for use as drinking water in accordance with the national regulations e g the Austrian Drinking Water Regulation TWV Federal Law Gazette II no 304 2001 deviations between the actual drinking water tempera...

Страница 22: ...rating voltage prevention of damage due to improper use etc From these conditions it can be concluded that if all requirements are met norms installation and operation guide general guidelines etc the device or product fault resulting in the secondary damages would not have occurred Furthermore it is mandatory that for processing of the claim the necessary documentation such as the part number and...

Отзывы: