AE EKA Скачать руководство пользователя страница 23

Warranty, Guarantee and Product Liability

The warranty is granted in accordance with the statutory provisions of the Republic of Austria, as well as of the EU.

1.   Prerequisite for the provision of warranty services by Austria Email AG (hereinafter referred to as AE AG) shall 

be the presentation of the paid invoice for the purchase of the device for which the warranty service is claimed, 
whereby the identity of the device with regard to the model and the manufacturing number must be evident 
from the invoice and must be documented by the claimant. The General Terms and Conditions, Terms and 
Conditions of Sale and Delivery of AE AG shall apply exclusively.

2.   To the extent required by the law, respectively in the Operator’s Manual and Installation Instructions, the as-

sembly, erection, connection and commissioning of the unit for which the claim is presented must have been 
carried out by a licensed electrician or installation firm, duly observing all applicable rules. The tank (without 
outer shell and plastic outer shell) must be protected from sunshine to avoid discolouring of the PU foam and 
potential warping of plastic components.

3.   The room in which the device is operated must be free of frost. The unit must be mounted in a location that 

may reasonably be expected, i.e. it must be possible to access and replace the unit without difficulty for the 
purpose of necessary maintenance, repairs and possible replacement. The costs for any necessary changes 
to the structural conditions (e.g. doors and passages too narrow) are not governed by the guarantee and 
warranty declaration and therefore shall be rejected on the part of AE AG. If the water boiler is set up and 
operated in uncommon locations (e.g. attics, living rooms with water-sensitive floors, store rooms, etc.), the 
possibility of water leakage must be taken into account and provisions made for collecting and discharging 
the water leakage in order to prevent secondary damage within the meaning of product liability.

4.   The following is not covered by the warranty and guarantee:
 

inappropriate transport, normal wear and tear, intentional or negligent damage, use of force of any kind or de-
scription, mechanical damage or damage caused by frost or also by exceeding the operating pressure stated 
on the rating plate, even if only once, use of connection fittings that do not comply with the standard, use of 
defective tank connection fittings and unsuitable and defective service fittings. Breaking of glass and plastic 
components, possible colour differences, damage due to improper use, in particular non-observance of the 
mounting  and  operating  instructions  (Operating  and  Mounting  Instructions),  damage  by  external  influence, 
connecting to incorrect voltage, corrosion damage as a consequence of aggressive waters (water not suitable 
for drinking) in accordance with the national regulations (e.g. Austrian ordinance on drinking water, TWV – Fed. 
Law Gazette II No. 304/2001), deviations between the actual drinking water temperature at the tank fitting 
and the specified hot water temperature of up to 10°K (hysteresis of the controller and possible cooling due to 
pipelines), Insufficient water conductivity (min. 150 µs/cm) operational wear of the magnesium anode (wearing 
part), natural formation of boiler scale, lack of water, fire, flood, lightning, overvoltage, power failure or other 
types of force majeure. Use of non-original and company-external components such as e.g. heating elements, 
reactive anode, thermostat, thermometer, ribbed tube heat exchanger, etc., Parts installed in an uninsulated 
condition with respect to the storage tank, ingress of foreign particles or electrochemical influences (e.g. mixed 
installations), failure to observe the design documents, unpunctual and undocumented renewal of the installed 
protective anode, no or improper cleaning and operation, as well as any deviations from the standard that redu-
ce the value or functionality of the device only slightly. Fundamental compliance with all regulations in ÖNORM 
B 2531, DIN 1988 (EN 806), DIN 1717, VDI 2035 or the corresponding national regulations and laws must be 
ensured.

5.   In the case of an authorised complaint, this must be reported to the next available customer service location 

of AE AG. The same reserves the right to decide whether a defect component shall be replaced or repaired 
or whether a defect device shall be replaced by an equivalent fault-free device. Furthermore, AE AG explicitly 
reserves the right to request that the rejected device be returned by the buyer.

6.   Repairs under warranty must be performed exclusively by persons authorised to do so by AE AG. Replaced 

parts shall remain the property of AE AG. If a repair of the hot water heater should be required in connection 
with necessary service work, the Manufacturer shall invoice these as repair and prorated material costs.

7.   Any intervention by third parties without our express instruction, even if performed by a licensed electrician, shall 

have the effect of voiding the warranty. Costs for repairs carried out by third parties shall be replaced only if AE 
AG has previously been requested to remove the defect and if AE AG shall have failed to satisfy its 

obligation 

to replace the defective item or repair the defect or if it shall have failed to do so within a reasonable period of 
time.

Содержание EKA

Страница 1: ...ter with control panel of the series EKA Wall mounted storage tank with 3 connecting pieces EKR Wall mounted storage tank with heat exchanger EWH Wall mounted storage tank with one heating element EKL Wall mounted storage tank horizontal Please pass to the user Id Nr 228843 13 ...

Страница 2: ... Because of the environmentally friendly CFC free insulation foam the standby energy consumption is extraordinarily low The ARA license of Austria Email AG lets you return of packaging of your device which will then be dispo sed of expertly to avoid environmental damage Installation and commissioning must be performed exclusively by an authorised installa tion company in accordance with these inst...

Страница 3: ...ty advice 8 11 Dimensioned drawing 9 11 1 Series EWH EKA EKR 9 11 2 Series EKL 11 12 Schematic drawing of the device 12 13 Water connection 13 13 1 Pressure resistant connection 13 13 2 Pressureless connection 15 13 3 Connection storage tank with 3 connecting pieces 16 14 Central heating connection only EKR 16 15 Electrical connection 17 15 1 General information 17 15 2 Reconnection possibilities ...

Страница 4: ... be heated with the system s water heater as an alternative to electrical heating 2 Hot water requirement The hot water requirement of the household depends on the number of persons in the household the sanitary installations of the flat or house the insulation the piping and the individual user s habits The following table provides a list of standard consumption values for orientation In this tab...

Страница 5: ...emperature constant during this period 4 1 Series EWH EKA EKR Nominal content in litres 50 80 100 120 150 200 Standby energy consumption kWh 24hrs measured according to EN 12897 0 52 0 71 0 78 0 83 0 95 1 25 4 2 Series EKL Nominal content in litres 80 100 120 150 200 Standby energy consumption kWh 24hrs measured according to EN 12897 1 15 1 25 1 29 1 52 1 84 5 Operation All operating elements requ...

Страница 6: ... If this setting is selected the operation of the device is extraordinarily eco nomical Heat losses are small and the build up of limescale is largely prevented Low standby energy consumption Approximately 85 C hot storage water N B Setting the control button all the way to the left does not switch off the heater no zero setting If the device is operated on daytime current it is recommended to set...

Страница 7: ...e local electricity company and water supply works as well as the installation and operation instructions is required The room where the device is operated must be free of frost The device must be installed in a re asonably expected location i e if the device needs to be maintained repaired or replaced it must be readily accessible If the water is very hard either of the following options is recom...

Страница 8: ...in suspended ceilings and similar always ensure that the connection side of the device water connections electrical connection chamber resp heating insert are freely accessible and that there is no accumulation of heat To remove the heating flange a free space of 500mm must be available To hook up the device in the wall rail ensure that there is a minimum clearance of 50mm on top of the device g W...

Страница 9: ...all mounted storage tank with reater battery Wall mounted storage tank 3 connecting pieces 600 400 700 300 921 520 520 66 50 EWH 120 Wall mounted storage tank 800 550 800 300 1056 520 520 55 EKR EKA 120 Wall mounted storage tank with reater battery Wall mounted storage tank 3 connecting pieces 800 550 800 300 1056 520 520 74 56 EWH 150 Wall mounted storage tank 800 750 1000 300 1256 520 520 63 EKR...

Страница 10: ...10 Id Nr 228843 13 Electric water heater EKA EKR EWH EKL Heating flow Heating return Cable entry Wall mounted storage tank with reater battery EKR Installation on a ceiling Thin wall suspension ...

Страница 11: ... kg A C H B T E EKL 80 Horizontal storage tank 500 150 780 480 480 80 42 EKL 100 Horizontal storage tank 500 300 904 480 480 80 52 EKL 120 Horizontal storage tank 500 300 1056 520 520 100 61 EKL 150 Horizontal storage tank 700 300 1256 520 520 100 66 EKL 200 Horizontal storage tank 1000 300 1590 520 520 100 77 Cable entry Brackets for EKL ...

Страница 12: ...ation Height adjustable hook Hot water pipe Heater Heater battery only EKR Lower wall bracket Cable entry Removeable cover for the connection chamber Controller Adjustment knob Control panel with thermometer and operation indikator lamp Magnesium anode Sensor tube Enamelled interior tank Outer jacket ...

Страница 13: ...torage tank in the indicated order As a general rule the following should be observed A faultless function of the connection fitting can only be guaranteed if it is installed in a frost protected room The drain of the safety valve must be open and observable To prevent disturbances and clogging due to frost or dirt and similar do not lead the drain line from the drip catcher expansion water funnel...

Страница 14: ...art If this is not successful get an installation company to carry out the repair If the valve seat or sealing shim is damaged the safety valve must be replaced completely To be performed by Installation company Interval once per year To check the non return valve close the stop valve If water exits through the open test valve the non return valve does not function properly The operation of the st...

Страница 15: ...ater inlet of the storage tank This means that the retrieval of hot water from the storage tank works as follows by opening the hot water valve cold water is pushed into the storage tank from below allowing the hot water to exit freely through the upper hot water drain via the overflow mixer tap The fittings for pressureless connection are built in such a way that the hot water drain always stays ...

Страница 16: ...ion to a water heater at a pressure of up to 6 bar A forced circulation with pump is required If the storage tank is connected to alternating current the pump can be controlled via the free charge pump contact The temperature setting of this contact is identical to the temperature level of the two con tacts for the fitted electric heater The bare tube heat exchanger of the EKR series must be flush...

Страница 17: ...e connection chamber of the storage tank b Ensure that the supply voltage is correct c Fit an all pole disconnector with 3mm contact opening width in the electric feeder Automatic circuit breakers can also be used as disconnectors d The connection cable must be fed through the cable screw connection into the con nection chamber of the storage tank and protected with a strain relief mechanism again...

Страница 18: ...nnectable heating times ratings and fusing current Bold figures represent the factory connection 6 hrs 230V Heater clamping Hea ting time hrs Heating times at mains voltage 230V 3 400V 3N 400V M 16 S 8 S M 6 S S 4 S M S 3 1 3 S M S wye conn 4 3 1 3 3 1 3 Storage tank content 50l kW A 0 30 2 0 65 6 0 95 6 1 30 6 1 60 10 Storage tank content 80l kW A 0 85 6 1 15 6 1 70 10 2 00 10 Storage tank conten...

Страница 19: ...ontent 100l kW A 1 10 6 1 75 10 2 20 10 2 85 16 2 80 6 Horizontal storage tank content 120l kW A 1 30 6 1 95 10 2 60 16 3 25 16 3 10 6 Horizontal storage tank content 150l kW A 1 65 10 2 30 16 3 30 16 3 70 10 3 95 10 Horizontal storage tank content 200l kW A 2 10 10 2 75 16 4 40 10 4 85 10 S side heater in flange M middle heater in flange 15 3 Connection diagram EWH L N Supply network Connection v...

Страница 20: ...3 hrs 4 hrs 3 1 3 hrs 3 1 3 hrs EKL 080 U 1 00 0 65 1 00 1 00 1 65 2 00 2 65 2 60 EKR 100 U EKA 100 U EKL 100 U 1 10 0 65 1 10 1 10 1 75 2 20 2 85 2 80 EKL 120 U 1 30 0 65 1 30 1 30 1 95 2 60 3 25 3 10 EKR 120 U EKA 120 U 1 35 0 65 1 35 1 35 2 00 2 70 3 35 3 20 EKR 150 U EKL 150 U 1 65 0 65 1 65 1 65 2 30 3 30 3 70 3 95 EKL 200 U 2 10 0 65 2 10 2 10 2 75 4 40 4 85 EKR 200 U 2 30 0 65 2 30 2 30 2 9...

Страница 21: ... the cold season if the device is not used for several days and if it is not operated in frost protection mode see page 6 item 6 Once the stop valve in the cold water supply line has been closed the water is drained through the drain valve of the safety valve combination Simultaneously all hot water valves of the connected fittings are opened Draining is also possible through the safety valve into...

Страница 22: ...ng when refitting the heating flange Any contact between the specially enamelled interior tank of the water heater and boiler scale dis solver must be avoided do not work with the deliming pump Scrape off deposited scale with wood and remove with a hoover or wipe with a cloth Finally flush the device thoroughly according to ÖNORM H5195 1 and observe the heating procedure as if the device was first...

Страница 23: ...se in particular non observance of the mounting and operating instructions Operating and Mounting Instructions damage by external influence connecting to incorrect voltage corrosion damage as a consequence of aggressive waters water not suitable for drinking in accordance with the national regulations e g Austrian ordinance on drinking water TWV Fed Law Gazette II No 304 2001 deviations between th...

Страница 24: ...anode replacement the connection to the correct ope rating voltage any damage due to improper use must be avoided etc These standards are based on the assumption that if all the regulations standards assembly and operating instructions general guidelines etc are observed the defect in the unit or product causal for occurrence of the secondary damage would not have occurred It is further imperative...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...00 0 Fax 03512 700 239 Internet www austria email at E Mail office austria email at Austria Email in your area For addresses and telephone numbers of our subsidiaries visit our homepage at www austria email at Print errors and changes of all kinds are reserved Reproduction prohibited ...

Отзывы: