97-7224006_3-31-15
Information subject to change
21
7224 OPERATOR’S MANUAL – SECTION 4
Figure 4.8 – Standby Mode on Over Temp Setting
Figure 4.9 – Standby Mode on Over Load Setting
4.2.6 Standby Mode on
Over Temp Setting
When enabled, the 7224 amplifier will move into
Standby mode when it senses any activation of
the Over Temperature circuit. The amplifier will
remain in Standby mode until the amplifier is reset.
To reset the amplifier, push and hold the Reset
switch on the amplifier front panel until the Stand
-
by LED goes out, then release the Reset switch.
Alternately, the amplifier will reset when a Reset
signal is received on the Interlock – I/O Connector.
Once reset, the amplifier will return to Run mode.
To enable S
tandby mode on Over Temp,
place
the jumper across the two pins labeled J12. See
Figure 4.8.
4.2.7 Standby Mode on
Over Load Setting
When enabled, the 7224 amplifier will move into
Standby mode when it senses an activation of the
IOC (Input/Output Comparator) Distortion Alert
circuit. The IOC Distortion Alert circuit continuously
compares the input waveform to the output wave-
form. When a distortion of more than 0.5% occurs,
the IOC circuit will activate. The amplifier will re
-
main in Standby Mode until the Reset switch on the
front panel is pushed or a Reset signal is received
on the Interlock – I/O Connector. Once reset, the
amplifier will return to Run mode. To enable
Stand
-
by mode on Over Load,
place the jumper across
the two pins labeled
J13.
See
Figure 4.9.
4.3
Configuration Settings Located on
the Power Supply Board
The following custom settings can be made via
plug-in connectors located on the Power Supply
Board:
•
Amplifier Voltage Potential setting (high current
or high voltage)
• Bi-Level Power Supply setting
4.3.1 Selecting the Best Voltage
Potential and Bi-Level Power Switch
Settings for Your Application
The output of the amplifier will be determined by
the combination of settings used for both Voltage
Potential and Bi-Level Power Switch.
OUTPUT VOLTAGE
Bi-Level
Switch Setting
Voltage Potential Setting
90
180
Auto
45-90
90-180
High
90
180
Low
45
90