31
5.1.4
TEST SET-UP
Select
Test
from the
Unit
menu or click on the
Start Test
icon. A dialog box will appear that
asks if you would like to select
Random
or
Sequential
testing. Select
Random
if you wish to
return to the computer after each slot or wedge is tested; select
Sequential
if you prefer to
test the whole machine, or only one part, wedge after wedge in a predefined order.
5.1.5
SEQUENTIAL TEST
If you select
Sequential
, the following dialog box will appear:
Figure 29: Sequential Test Dialog Box
The
Sequential Test
dialog box has several fields that require input. Some are drop down
limited choice selections, and others are typed in.
The first two fields on the top left of the dialog box are for the number of slots and the
number of wedges. These are plugged in automatically from the unit and station name tabs
when they were opened or created.
Just below those two fields are check boxes to indicate whether you want to test
All Wedges
or
Make Groups
of wedges to test in a predefined sequence. Only one of these can be
selected.
To test complete machine, click on All wedges. (This option is offered by default)
To make groups, click off All wedges and click on Make groups. Up to ten groups can be
made and each group can range from only one wedge up to the whole generator.
NOTE: If groups overlap, chronologically, the later measurements will be saved, only.
The fields located below the check boxes permit the groups to be defined, if that check box
was selected. The
Description
field allows each group to be named, and the slots and
wedges to be listed.