Page 18
Commtnd connection
Eliectrictli connection
For 6000 tnd 7000 veraiona:
Connection of the termintli bliock on 1 ainglie
-
phtae 32A liine with t 32A circuit bretker.
-
N + N on neutral conductor
-
PH front + PH rear on Phase conductor
-
PE on earth conductor
First of all, unscrew the protective cover
Connection of the termintli bliock on 2 ainglie
-
phtae 16A liinea with 2 circuit bretkera.
(The neutral connections are bridged)
-
N on Neutral conductor line 1
-
PH front on Phase conductor line 1
-
PE on earth conductor line 1
And
-
N on Neutral conductor line 2
-
PH rear on Phase conductor line 2
-
PE on earth conductor line 2
Connection of the termintli bliock on 1 three
-
phtae
-
N + N on Neutral conductor
-
PH front on Phase conductor 1 (ph1)
-
PH rear on Phase conductor 2 (ph2)
-
PE on earth conductor
NB: nothing is connected on phase 3 (ph3)
It is necessary to connect the 2 cables of the
block command respectively on 2 connectors
SUBD
-
9.
So to lock the connections, it is imperative to
screw 2 binding screws of every connector.
Also, it is imperative to connect the
ground wire of the block commands to the
Ground.