8.4 

 Reset To Factory Defaults 

 

To reset the controller to its factory default settings do the following:

 

1.

 

Hold down the “Factory IP” button AND the “Bootloader” buttons together before applying 
power.

 

2.

 

Power up the board.

 

3.

 

Wait for both LEDs to flash together.

 

4.

 

Release both buttons.

 

5.

 

Power cycle (turn power off, wait 5 seconds then turn it on again).

 

 

 

Содержание PIXLITE 4

Страница 1: ...PIXLITE 4 HARDWARE REV 1 1 USER MANUAL V1 3...

Страница 2: ...ng 8 4 2 1 Using a Router 8 4 2 2 Using A Switch Direct 8 4 2 3 Forcing the Default IP Address 9 5 Operation 10 5 1 Startup 10 5 2 Sending Data 10 5 3 Outputs 10 5 3 1 Pixel Outputs 10 5 3 2 DMX512 Ou...

Страница 3: ...2 PixLite 4 V1 1 User Manual V1 3 2015 Advatek Lighting Pty Ltd 8 1 LED Codes 16 8 2 No Status Power LEDs On 16 8 3 Other Issues 16 8 4 Reset To Factory Defaults 17 9 Warranty and Service 18...

Страница 4: ...universes of either multicast unicast E1 31 or Art net data in addition to a single DMX512 universe output 17 universes of data total This combined with an advanced feature set and easy to use configu...

Страница 5: ...applied via a screw terminal connector located on the left hand edge of the board as shown in Figure 1 Polarity is clearly marked on the PCB Voltage to the power input is recommended to be between 5V...

Страница 6: ...ed to inject power into the pixels directly off board The logic circuitry is protected by a 1A mini blade fuse This is located on the lower right hand edge of the board 3 3 Control Data Control data t...

Страница 7: ...hort ve onto the clock or data lines when using pixels greater than 5v Given this mistake can happen the part it damages has been designed for easy replacement by the user The part is very cheap to re...

Страница 8: ...controller s If you are only using a few controllers they can be connected straight to the router Larger installations will benefit from using a network switch between the router and controllers Usin...

Страница 9: ...y indicating it is in run mode and ready for use If a static IP address is assigned to the board then the power LED will be solid from power up If a DHCP timeout occurs the power LED will stop flashin...

Страница 10: ...u forget the IP of a controller and you can t see it in the Assistant it can be forced to its default IP A simple procedure can be employed on power up 1 Hold down the Factory IP button and power up t...

Страница 11: ...xels out of a single output would also likely require power injection How much power you need to inject and how often will typically vary depending on the number of pixels used their voltage and their...

Страница 12: ...ssing the button while in this mode will then cycle through each of the four colors successively on all outputs simultaneously before returning to the current pattern again To exit the test mode simpl...

Страница 13: ...s still visible in the configuration utility Otherwise refer to the troubleshooting section for further information Figure 5 6 4 Performing a Forced Boot Update 1 Power down the controller and then ho...

Страница 14: ...ing Pty Ltd 5 Click on the update button The update will only take about 5 seconds and a message box will pop up once the download is completed 6 Power the board down again 7 Apply power again and the...

Страница 15: ...ecommended Voltage 5 12 V DC Max Capacity 30 A Logic Current Consumption 5V DC 130 mA Recommended Ambient Temperature2 20 to 50 C PCB Component Absolute Maximum Temperature 40 to 80 C Maximum Current...

Страница 16: ...15 PixLite 4 V1 1 User Manual V1 3 2015 Advatek Lighting Pty Ltd 7 2 Mechanical Specifications The controller s dimensions are shown in Figure 6 below Figure 6...

Страница 17: ...R IS OFF Table 3 8 2 No Status Power LEDs On Firstly check that the 1A logic fuse has not blown Ensure that your power supply is supplying correct voltage as per section 3 1 Also ensure that it can su...

Страница 18: ...e you will have the ability to login and manage past and existing tickets 8 4 Reset To Factory Defaults To reset the controller to its factory default settings do the following 1 Hold down the Factory...

Страница 19: ...warranty cases the support staff will usually require you to perform some troubleshooting steps first If we cannot solve your problem remotely we will issue you with an RMA number through the support...

Отзывы: