FCC Warning 

 

This equipment has been tested and found to comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio 
frequency energy, and if it is not installed and used in accordance with the instruction 
manual, it may cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference, in which case the 
user will be required to correct the interference at his own expense. 

 
*Shielded interface cables must be used in order to comply with emission limits 

 

Changes or modifications to the equipment, which are not approved by the party 
responsible for compliance, could affect the user's authority to operate the equipment. 
 

Copyright_1999 All Rights Reserved.

 

Company has an on-going policy of upgrading its products and it may be possible 
that information in this document is not up-to-date. 
Please check with your local distributors for the latest information. 
No part of this document can be copied or reproduced in any form without written 
consent from the company. 
 

CE Mark Warning: 

This is a Class A product. In a domestic environment, this product may cause radio 
interference, in which case the user may be required to take adequate measures. 
 
 

Trademarks:  

All trade names and trademarks are the properties of their respective companies.   

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание ANS-24RV

Страница 1: ...24 Port Fast Ethernet Switch with VLAN and Trunking User Manual Model ANS 24RV ...

Страница 2: ...s own expense Shielded interface cables must be used in order to comply with emission limits Changes or modifications to the equipment which are not approved by the party responsible for compliance could affect the user s authority to operate the equipment Copyright_1999 All Rights Reserved Company has an on going policy of upgrading its products and it may be possible that information in this doc...

Страница 3: ... Login the SmartSwitch Web Base Controller 9 2 3 The SmartSwitch Home overview 10 2 4 Administrator 11 2 4 1 Authentication Configuration 11 2 4 2 System IP Configuration 12 2 4 3 System Status 12 2 4 4 Load Default Setting 13 2 4 5 Firmware update 14 2 5 Port Management 16 2 5 1 Port Configuration 16 2 5 2 Port Mirroring 17 2 5 3 Bandwidth Control 17 2 5 4 Broadcast Storm Control 18 2 6 VLAN Sett...

Страница 4: ... Configuration 22 2 10 Configuration 22 2 10 1 Configuration Backup Recovery 22 3 Console User Interface 24 3 1 Connecting to the Switch Console Port 24 3 2 Setup HyperTerminal 24 3 3 Configure Switching Hub via COM1 Port 27 3 3 1 Switch Main Menu 27 3 3 2 Load Default Setting 27 ...

Страница 5: ... Product Features Complies with 10BASE T specifications of the IEEE802 3 standard Complies with 100BASE TX specifications of the IEEE802 3u standard RJ 45 ports for 100Base TX and 10Base T connectivity Supports Nway protocol for speed 10 100Mbps and duplex mode Half Full auto detection Supports full and half duplex operation on all ports Supports back pressure half duplex and flow control IEEE802 ...

Страница 6: ...ear panel Rear Panel of the switching hub has a RS232 Connector a power cord socket 1 6 Power Connecting Plug the circle end of the power cord firmly into the power port on the switch rear panel and the other end into an electric service outlet then the system is ready 1 7 Connecting computers to the switch The switch features auto MDI MDIX crossover detection function and provides plug and play c...

Страница 7: ...distance to 100m for linking another switch or hub 1 9 To prolong the operational life of your units Never stack units more than eight high if freestanding Do not place objects on top of any unit or stack Do not obstruct any vents at the sides of the case ...

Страница 8: ...t Æ Settings Æ Control Panel double click Network icon select Configuration tab then choose TCI IP to configure system network setting For Windows 2000 and XP click Start Æ Control Panel Æ Network and Internet Connections Æ Network Connections then right click LAN icon to configure system network setting Below shown the steps to configure network settings in Windows XP Step 1 Right click LAN icon ...

Страница 9: ...ubnet mask and Default gateway fields and then click OK 2 2 Login the Web Step 1 Enter IP address Æ http 192 168 2 1 in the web browser URL field Step 2 When Login window pops out enter Username Password The default Username is admin and the default Password is system ...

Страница 10: ...10 2 3 The SmartSwitch Home overview The window below shows the Home page of SmartSwitch Administrator Æ1 Authentication Configuration 2 System IP configuration ...

Страница 11: ...etting Æ1 Group VLAN Setting 2 Multi to 1 Setting Trunk Setting Æ Trunk Configuration QoS Setting Æ 1 Priority Mode 2 Class of Service Configuration MAC Address Æ MAC Address Configuration Configuration Æ Configuration Backup Recovery 2 4 Administrator 2 4 1 Authentication Configuration This page allows you to change your Username Password Maximum up to 15 characters ...

Страница 12: ...et Mask and Gateway setting After filling up the data that you want to change click Update to process the data changed immediately 2 4 3 System Status Click on System Status to present the current system status on this screen It will show the MAC address Number of Ports and System Version ...

Страница 13: ...he default setting from the factory Be aware that the entire configuration will be reset the IP address of the device will be set to default setting 192 168 2 1 Just simply click Load to reset the default setting After the reset process is completed you will see the screen as below ...

Страница 14: ...DP ports enabled Make sure both Windows firewall Anti Virus firewall do NOT block the data transfer To disable the firewall of Windows please follow the following procedures My Computer Æ Control Panel Æ Network and Dial up connection Æ select the network connection and click right button Æ Property Æ Advanced Do NOT enable the firewall since the firewall will probably block the UDP port 67 port 6...

Страница 15: ...configuration procedure for DHCP BootP server is illustrated as the following figures Step1 Click the Settings item and set base Directory Step2 To update the firmware through this program you should select TFTP server DHCP server and Syslog server Step3 Click the DHCP Server item and setup items shown below After finishing the settings click SAVE item to save the configuration ...

Страница 16: ...r as shown below If no throughput can be seen on this program there may be something wrong with your settings Please go back to check your setting step by step 2 5 Port Management 2 5 1 Port Configuration In Port Configuration this page will show each port s status and setting status You can set each port s configuration on the top of page and click Update to save the change ...

Страница 17: ... and or outgoing packet from one port of a network switch to another port where the packet can be studied It enables the manager to keep Close track of switch performance and alter it if necessary 2 5 3 Bandwidth Control Limit speed of any ports In this page you can set each port s TX transmit rate and RX receive rate ...

Страница 18: ...te of data that send to the source and forward to the sniffer port 2 5 4 Broadcast Storm Control You can enable Broadcast Storm Control to configure the advanced switch function The value indicates the number of broadcast packet which is allowed to enter each port in one time unit One time unit is 10 ms for 100Mbps speed and 100ms for 10Mbps speed ...

Страница 19: ...ts within the same VLAB group s of the source port except the source port itself A unicast packet will be forwarded to the destination port only if the destination port is in the same VLAN group as the source port Organize your VLAN groups in this page Each row is a group any individual port can be a member of a VLAN group and each group comprises at least two members Source port is mark and desti...

Страница 20: ...20 2 7 Trunk Setting 2 7 1 Trunk Configuration Port trunk setting The trunk hash algorithm can select Port ID Source address Destination address or SD DA ...

Страница 21: ...service for high priority frames to some extent depending on the load condition of incoming traffic At least the high priority service offers better than that of best effort service It also provides different service ratio settings for users to shape the prioritized frames on the streams in the incoming traffic 2 8 2 Class of Service Configuration High Low Priority setting Specify high or low prio...

Страница 22: ...ty enabled Default All ports in TCI priority recognition disabled 2 9 MAC Address 2 9 1 MAC Address Configuration This page allows user define which MAC address can be entry to the port You can assign three MAC address for every port Then only the three users can pas this port It will lock them and avoid to hacker Default is all ff ff ff ff ff ff It means all users can pass ...

Страница 23: ...23 2 10 Configuration 2 10 1 Configuration Backup Recovery This function allows you to backup or recovery the latest switch settings Just simply enter your password and click Update button ...

Страница 24: ...ng hub make sure you connect the other end of serial port to COM1 of PC Note When you use HyperTerminal with MS Windows 2000 make sure that you have Windows 2000 Service Pack 2 or later are installed Otherwise the arrow keys do not function properly under HyperTerminal s VT100 emulation 3 2 Setup HyperTerminal Please follow the steps to setup the HyperTerminal Step 1 Click Start Æ All Programs Æ A...

Страница 25: ...25 Step 2 The Connection windows will appear Enter terminal Name select correct icon and then click Ok button Step 3 Select COM1 in the Connect using field and then click OK ...

Страница 26: ...e the settings Step 5 Reset or pull out the switch power And then the HyperTerminal screen will appear Wait for a while for system checking and then press s to enter the console Note If you press other key you won t into the console please reset the power again and repeat this step ...

Страница 27: ...onfigure Switching Hub via COM1 Port 3 3 1 Switch Main Menu After you enter the Modular Console the Switch Main Menu will appear 3 3 2 Load Default Setting This page allows user to restore default port settings ...

Страница 28: ... option to 3rd option 1 Restore switch default setting 2 Restore IP default Setting 3 Restore Login default Setting just simply press number to restore the default settings Press 4 to enter Modify IP setting screen ...