Note: Please Refer to Figure A.4 and A.5 for location of SW3
Note: After changing the jumper, please also adjust the IRQ through the
device manager software for the new settings to work properly. (Refer to
UNO Serial Port Installation Guide in the CD, steps 7 ~ 10)
You can adjust the transmission rate by the second switch of SW3.
* To increase the normal baud rates by eight times, (e.g. if we set the baud
rate as 115.2K bps in software, then the actual hardware baud rate will be
increased to 921.6K bps), set switch 2 of SW3 to “on”.
Note: Only COM3 and COM4 can adjust the transmission rate.
Table 2.2: IRQ Setting via switch 1 at SW3
Switch 1 at SW3 setting
Function
Share IRQ (default)
Independent IRQ
Table 2.3: Transmission Rate Settings (Switch 2 at SW3)
Switch 2 at SW3 setting
Function
Speed x 8*
Speed x 1 (default)
1
2
O
N
1
2
O
N
1
2
O
N
1
2
O
N