3 8
PCLS-848-P User's Manual
3.4.13. ieppollc
NAME:
ieppollc
—
Parallel poll configure.
SYNTAX:
ieppollc(addr,config);
addr:integer;
The address of the device to be configured. If 0 <= addr <= 30,
then the specified device is configured. Otherwise, the
previously defined listener(s) are configured.
config:integer;
An integer sent to configure the specified device indicating
how and which data line to respond. Bits 4-15 are not used.
DESCRIPTION:
This procedure performs a Parallel Poll Configure. In prepa ration for a parallel
poll command, it enables you to tell a device how to respond to the parallel poll,
and on which data line to respond. In general, it enables you to configure a parallel
poll response byte to reflect the response of a desired arrangement of devices.
You can define the bits to reflect the responses of particular instruments or the
logical-OR of several instrument responses.
Bit
3
2
1
0
Indicates line 0-7 (DI01-8)
O : Responds with O
1 : Responds with 1
Содержание PCLS-848-P
Страница 1: ...PCLS 848 P IEEE 488 INTERFACE CARD PASCA SUPPORT PACKAGE USER S MANUAL...
Страница 6: ...Figures Figuree 7 1 PCL 848A B Block Diagram 77...
Страница 10: ...4 PCLS 848 P User s Manual...
Страница 20: ...14 PCLS 848 P User s Manual...
Страница 32: ...26 PCLS 848 P User s Manual If addr 0 or addr 30 ATN is set false String is entered...
Страница 37: ...CHAPTER 2 INSTALLATION 31 ieinit ioport myaddr setting...
Страница 42: ...36 PCLS 848 P User s Manual If addr 0 or addr 30 ATN is set false Long string is sent...
Страница 56: ...50 PCLS 848 P User s Manual...
Страница 80: ...74 PCLS 848 P User s Manual...
Страница 83: ...CHAPTER 7 THEORY OF OPERATION 77 Figuree 7 1 PCL 848A B Block Diagram...
Страница 84: ...78 PCLS 848 P User s Manual...
Страница 95: ...CHAPTER 7 THEORY OF OPERATION 89...
Страница 97: ...CHAPTER 7 THEORY OF OPERATION 91 Handshake Timing Sequence...
Страница 102: ...96 PCLS 848 P User s Manual...