Chapter 2 Hardware Installation 9
Configuration software/jumper (JP4)
As already mentioned you can configure the PCL-843 with the above
jumpers or via the software utility. This option is selected via pins 3
and 4 on jumper JP4, as shown below:
Software
Jumpers (default)
Interrupt level (IRQ) setting (JP2)
The PCL-843 card is designed to access interrupt levels 2 up to level
12 with the exception of 7, 8, and 9. Simply place the jumper link on
the required interrupt level as shown below:
IRQ 3 (default)
The table below shows the possible IRQ settings available for the
PCL-843. Ensure that the IRQ does not conflict with any other card's
IRQ you that you have installed in your system .
PCL-843 IRQ Settings (JP2)
IRQ
Pin 1-2
Pin 3-4
Pin 5-6
2
¡
¡
¡
3
¡
¡
l
4
¡
l
¡
5
¡
l
l
6
l
¡
¡
1 0
l
¡
l
1 1
l
l
¡
1 2
l
l
l
l
:Close
¡
:Open
*:Default
1
2
3
4
1
2
3
4
1
3
5
2
4
6
*