Chapter 2 Hardware Installation 13
I/O Address and Interrupt Setup
I/O Address Setup
The I/O base address the PC-740 is selectable by a 6 position DIP
switch, SW1. Refer to page 9 for the locations of the DIP switch
SW1. The base address can be set anywhere in the I/O address area
from hex 200 to hex 3F8. If you have more than one card installed
you must select a different base address for each card. The factory
default settings for the base address is Hex 3F8.
Desktop computer
Tx
Rx
Tx
Rx
Rx
Tx
Rx
Tx
Workstation
Plotter
Active
Passive
Passive
Active
Active
Active
Passive
Passive
PCL-740
port 1
port 1
or
SW1: Default base address - 3F8
The required switch settings for various base addresses are as shown
on the next page:
ON
A3
A4
A5
A6
A7
A8
Содержание PCL-740