MVP-3245 User Manual
4
1.2.2.5
Digital Output
1.2.3
I/O Connector
1.2.3.1
Digital Input
1.2.3.2
Digital Output
1.3
Safety Precautions
The following safety precautions can help customers with establishing a connection.
Generally, a standard cable is enough for the connection.
Protection
2,500 V isolation
Item
Description
Channel
SVON, ERC, CMP, CAM-DO
Output Voltage Low
10 V
DC
High
30 V
DC
Maximum Sink Current
100 mA / channel
Protection
2,500 V isolation
Item
Description
Channel
16
Input Voltage
Low
Max 2 V
DC
High
Min 5 V
DC
Max 30 V
DC
Maximum Delay
Time
100
μ
s
Protection
2,500 V isolation
Item
Description
Channel
16
Output Voltage
10
~
30 V
Maximum Sink Current
300 mA / channel
Protection
2,500 V isolation
Note!
Always disconnect the power cord from the chassis when making
adjustments. Do not connect when the power is on. A power spike can
damage sensitive electronic components. Only experienced electronics
personnel should open the chassis.
Note!
Always ground yourself to remove any static electricity before touching
the MVP-3245. Modern electronic devices are very sensitive to static
electricity. Use a grounding wrist strap at all times. Place all electronic
components on a static-dissipative surface or in a static-shielded bag.
Содержание MVP-3245 Series
Страница 1: ...User Manual MVP 3245 Series 4 Axis Embedded Motion Controller...
Страница 6: ...MVP 3245 User Manual vi...
Страница 14: ...MVP 3245 User Manual 6 Figure 1 3 Left View of the MVP 3245...
Страница 16: ...MVP 3245 User Manual 8...
Страница 17: ...Chapter 2 2 Hardware Function...
Страница 22: ...MVP 3245 User Manual 14...
Страница 23: ...Chapter 3 3 Motion and I O Control...
Страница 33: ...25 MVP 3245 User Manual Chapter 3 Motion and I O Control...