background image

Start Guide

Configuration

1. Configuring the Device Using the Web Browser

You can access the router for status monitoring, configuration, and administration after en-

tering the IP address of the router into a Web browser. The default IP address is 192.168.1.1
(netmask 255.255.255.0). Configuration access is allowed for the user

root

. The default pass-

word is printed on the router’s label.

1

Attention, it is necessary to use HTTPS protocol for

secure communication over a network! For a detailed description and examples of the router
configurations, see the Configuration Manual.

Important Notes

After logging on to the device for the first time, we strongly recommend changing the
default password due to security reasons.

For security reasons, it is highly recommended to update the firmware of the router to the
latest version regularly. Downgrading the firmware to an older version than the production
version or uploading a firmware intended for a different device may cause the malfunction
of the device.

2. Configuration Settings via WebAccess/DMP

Your router has been pre-installed with the WebAccess/DMP client. If you enable it in

the router’s web interface, you may configure the router from WebAccess/DMP. Navigate your
browser to:

https://www.wadmp.com

If this is your first time, please self-sign-up with the site. If not, please login with your

username and password. Once logged in, further assistance can be found here:

https://docs.wadmp.com

3. Restoring and Backing up the Router Configuration

After you reset the router, the current configuration is overwritten by the default settings.

We recommend that you back up the router configuration before resetting the device. Refer to
the Configuration Manual for more information.

When the

PWR

LED starts blinking, it is possible to restore the default configuration of

the router by pressing the

RST

button on the front panel of the router. Note that the RST

button is located under the cover – unscrew the cover. After pressing this button, the default
configuration is restored and then the router reboots (green LED will be on).

1

If the router’s label does not contain a unique password, use the password "root".

QSG-0007-EN, April 29, 2020

6

Released in the Czech Republic

Содержание ICR-3831

Страница 1: ...Start Guide ICR 3831 ...

Страница 2: ...he router Caution The SIM card can be swallowed by small children When connecting the device to a power supply do not exceed the defined voltage Do not expose the router to extreme ambient conditions Protect the router against dust moisture and high temperature It is recommended that you do not use the router at petrol filling stations We recommend observing local restrictions concerning the use o...

Страница 3: ...ith complete license texts can be found on the device itself See Licenses link at the bottom of the router s main Web page General Status or point your browser to this address replace the DEVICE_IP string with real router s IP address https DEVICE_IP licenses cgi This is a written offer valid for 3 years since the device purchase offering any third party for a charge no more than the cost of physi...

Страница 4: ...s necessary to insert a SIM card If you do not have connected the main antenna during operation of the router the router can be damaged 1 Antenna Use TNC connectors to connect the antennas to the router The main antenna is connected to the router by screwing on the ANT connector see the figure below The second diversity antenna can also be connected to the DIV connector to improve performance QSG ...

Страница 5: ...ntend to use this device to communicate over a cellular network please place an activated data provisioned SIM card with an unblocked PIN into the SIM card reader Unscrew the cover and push your SIM card into the SIM1 or SIM2 slot until it clicks in place Disconnect the router from power supply before handling of the SIM card QSG 0007 EN April 29 2020 4 Released in the Czech Republic ...

Страница 6: ...ee the figure below 4 Ethernet An Ethernet cable may be connected to the ETH0 connector on the rear panel of the router see the figure above By default the Ethernet port is configured as follows Connector Purpose Default Setting ETH0 LAN port default Connect your laptop or PC to this port to get a local web server for device configu ration and diagnostics DHCP Server enabled IP Address 192 168 1 1...

Страница 7: ...2 Configuration Settings via WebAccess DMP Your router has been pre installed with the WebAccess DMP client If you enable it in the router s web interface you may configure the router from WebAccess DMP Navigate your browser to https www wadmp com If this is your first time please self sign up with the site If not please login with your username and password Once logged in further assistance can b...

Страница 8: ...w advantech bb cz download Hereby Advantech Czech s r o declares that the radio equipment type ICR 3831 is in compliance with Directive 2014 53 EU The full text of the EU Declaration of Conformity is available at the following internet address www advantech bb cz eudoc QSG 0007 EN April 29 2020 7 Released in the Czech Republic ...

Отзывы: