ICR-3201
2.5
Serial Interfaces and I/O Port
The RS232 and RS485 serial interfaces together with the I/O interface are physically con-
nected to the 10-pin panel socket. All three interfaces are not isolated from the router. The
pinout of this conector is described in the tables below.
Figure 12: I/O connector
Pin
Signal mark
Description
1
B (+)
IN/OUT
2
A (-)
IN/OUT
3
GND
GROUND
Table 8: Connection of RS485
We recommend connecting a termination resistor outside the router. Without termination re-
sistors, signal reflections off the unterminated end of the cable can cause data corruption.
Termination resistors also reduce electrical noise sensitivity due to the lower impedance.
Pin
Signal mark
Description
4
BIN
BINARY IN
5
BOUT
BINARY OUT
Table 9: Connection of I/O
Pin
Signal mark
Description
6
RXD
IN
7
CTS
IN
8
GND
GROUND
9
RTS
OUT
10
TXD
OUT
Table 10: Connection of RS232
The I/O user interface is designed for binary input processing and binary output control.
By default, the binary output is open, so it is not grounded. The maximum binary output load
is 36 V at 500 mA. The constant current supplied by the binary input is 3 mA.