background image

ICR-2412

Appendix A: Troubleshooting

If you cannot connect to the router from your PC, your network card may be configured
in such a way that it is not possible to connect to the router. Take one or more of the
following steps in order to solve the problem:

Make sure your PC’s network card is configured to obtain the IP address form the
DHCP server (by default the DHCP server is running in the router).

Connect the router to the PC via Switch.

Connect the router to the PC, start the router first and then start the PC after the
router’s initialization.

-

Ethernet connection fails or is not establishing.

It is possible to turn auto negotiation off and set a rate and duplex manually on the
Ethernet interface of the router. Available on "LAN Configuration" page in the router.

-

Mobile WAN connection fails.

Check the signal power ("Mobile WAN status" page). If the signal power is weak,
you will have to use a better antenna. If the neighbouring cells have a similar signal
strength, you will need to use a directional antenna. For proper operation, the signal
levels have to be good.

Try to enable automatic ping from the router, which will check the connection when
there are no data running and in the case of a failed ping, restart the connection.
This can be done on the "Mobile WAN Configuration" page in the router in the
"Check connection" section. " bind" option is to ensure the ping goes
always through Mobile WAN network interface.

-

Mobile WAN connection cannot be established.

Check the "Mobile WAN Configuration" – APN, name, password and IP address (all
can be blank).

Try to enter the SIM card PIN – verify that the SIM card has the PIN code entered.
Available on "Unlock SIM Card" page in the "Administration" section.

In a private APN it is not recommended to get the DNS settings from operator (on
"Mobile WAN" page)

Go to "System Log" page in "Status" section and observe where the error occurs.

-

I cannot connect from the Internet to the device behind the router. I have NAT

enabled.

The device’s gateway has to be configured so it points to the router.

28

LUCOM GmbH    —   Flößaustr. 22a   —   90763 Fürth   —   Tel.:  +49 911/ 957 606 00   —   E-Mail: [email protected]   —   www.lucom.de

www

.lucom.de

Содержание ICR-2412

Страница 1: ...LTE Industrial Router ICR 2412 USER MANUAL LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 2: ...a commitment on the part of Advantech Advantech Czech s r o shall not be liable for incidental or consequential damages resulting from the furnish ing performance or use of this manual All brand names used in this manual are the registered trademarks of their respective owners The use of trademarks or other designations in this publication is for reference purposes only and does not constitute an ...

Страница 3: ...rmation of special interest GPL licence Source codes under GPL licence are available at https icr advantech cz source code address Advantech Czech s r o Sokolska 71 562 04 Usti nad Orlici Czech Republic Document No MAN 0070 EN revision from April 4 2022 Released in the Czech Republic ii LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 4: ... Port Interfaces 16 2 6 Serial Interfaces 17 2 7 LED Status Indication 18 2 8 Reset Functions 19 3 First Use 21 3 1 Powering up the Router 21 3 2 Router Configuration 21 4 Technical Specifications 23 4 1 Basic Parameters 23 4 2 Standards and Regulations 24 4 3 Type Tests and Environmental Conditions 25 4 4 Parameters of Cellular Module 26 4 5 Parameters of I O Ports 27 4 6 System Configuration 27 ...

Страница 5: ...ICR 2412 Appendix D Related Documents 34 iv LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 6: ...ip 10 8 Position of the DIN Rail Clip 11 9 Removing Router from the DIN Rail 11 10 Label Example 12 5 SIM Cards Insertion 13 6 Ethernet Connector Pinout 14 7 Connection of Power Supply 15 8 Position of the Grounding Screw 15 9 I O Connector Pinout 16 10 Functional Scheme of the Binary Interface 16 11 RS485 and RS232 Pinout 17 12 Resetting the Router 19 13 Router s Web Interface 22 v LUCOM GmbH Flö...

Страница 7: ... 6 Connection of RS232 17 7 LED Status Indication 18 8 Overview of Router Reboot and Reset 20 9 Basic Parameters 23 10 Standards and Regulations 24 11 Type Tests and Environmental Conditions 25 12 Technical Parameters of Cellular Module 26 13 Electrical Characteristics of Binary Inputs 27 14 System Configuration 27 1 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de w...

Страница 8: ...ntly configurable Ethernet ports RS232 and RS485 serial ports and with one digital input together with one digital output The router supports VPN tunnel creation using various protocols to ensure safe commu nications The router provides diagnostic functions which include automatic monitoring of the wireless and wired connections automatic restart in case of connection losses and a hard ware watchd...

Страница 9: ...basic situations I Access to the Internet from LAN Figure 1 Access to the Internet from LAN II Backed up access to the Internet from LAN Figure 2 Backed up Access to the Internet 3 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 10: ...ure networks interconnection or using VPN Figure 3 Using VPN Tunnel IV Serial Gateway Figure 4 Serial Gateway 4 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 11: ...cription 1 Grounding screw M3 Pay attention to proper grounding see Chapter 2 4 2 PWR 6 pin terminal Power supply socket see Chapter 2 4 2 IN OUT 6 pin terminal Binary input output interfaces see Chapter 2 5 4 LEDs Status LED indication see Chapter 2 7 5 RST Button to reboot the router or to restore the default configuration see Chapter 2 8 Continued on the next page 5 LUCOM GmbH Flößaustr 22a 907...

Страница 12: ... DIN rail clip not included as standard accessories see Chapter 1 9 11 Wall clip Wall mounting clip included as standard accessories see Chapter 1 8 Table 1 Hardware Overview of the Router 1 4 Order Codes Order codes overview is shown in the table below Order code Features interfaces ICR 2412 LTE Cat M Cat NB with 3G 2G fallback cellular module 64 MB NOR Flash 2x ETH 1x RS232 1x RS485 1x Binary In...

Страница 13: ...with screws 1 set 3 6 pin terminal block for power sup ply digital input and digital output de ployed on the router 1 pcs 4 7 pin terminal block for RS485 and RS232 deployed on the router 1 pcs 5 Printed Quick Start Guide notes 1 pcs Table 1 Contents of Package 7 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 14: ...he figures below Note that all sizes are measured in millimeters Figure 5 Product Dimensions Front View Figure 6 Product Dimensions with wall mounting clip Top View 8 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 15: ...is recommended to observe a minimum distance of 6 cm from ca bles and metal surfaces on every side in order to avoid interference When using an external antenna separate from the switchboard it is necessary to fit a lightning conduc tor When mounting a router on sheet steel we recommend using a cable antenna For all cables we recommend to bind the bunch and for this we recommend The length of the ...

Страница 16: ... clip There are two wholes on the clip with a diameter of 4 millimeters For detailed information about the mounting dimensions see Figure 6 in Chapter 1 6 When mounting the wall mounting clip tighten the screws with max torque of 0 4 Nm Figure 7 Screwed Wall Mounting Clip 10 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 17: ... DIN rail clip tighten the screws with max torque of 0 4 Nm Figure 8 Position of the DIN Rail Clip To remove the router from the DIN rail it is necessary to lightly push down the router so that the bottom part of the DIN rail clip hitched to the DIN rail get out of this rail and then fold out the bottom part of the router away from the DIN rail see Figure 9 Figure 9 Removing Router from the DIN Ra...

Страница 18: ...l An example of the product label with all the information printed on it is in the figure below Figure 10 Label Example 12 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 19: ...nging procedure is described below Type of SIM cards micro SIM 3FF 15 0 x 12 0 x 0 76 mm Inserting the SIM card Always disconnect the router from the power supply before handling the SIM card Unscrew two screws on the SIM card cover and remove the cover To remove an inserted SIM card use the flat end of a spudger or your fingernail press the SIM card slightly into its slot until you hear a click A...

Страница 20: ...onnector is 0 9 Nm 2 3 Ethernet Interfaces The panel socket of RJ45 is used for Ethernet interface The pinout of the socket is shown in Figure 6 and described in Table 2 Figure 6 Ethernet Connector Pinout Pin Signal mark Description 1 TXD Transmit Data positive pole 2 TXD Transmit Data negative pole 3 RXD Receive Data positive pole 4 5 6 RXD Receive Data negative pole 7 8 Table 2 Ethernet Connecto...

Страница 21: ...on Figure 7 Protection against reversed polarity without signaling is built into the router For correct operation it is necessary that the power source is able to supply a peak current of 1 A Unit has to be supplied by a power supply specified as a Limited Power Source LPS or CEC NEC Class 2 source of supply The metal case of the router is not connected to the negative pole of the power sup ply co...

Страница 22: ...Signal mark Description 3 IN The binary input positive pole 4 IN The binary input negative pole 5 OUT The binary output positive pole 6 OUT The binary output negative pole Table 4 I O Ports Pinout The I O user interface is designed for binary input processing and binary output control For detailed electrical parameters see Chapter 4 5 The functional scheme of connection for the binary input and bi...

Страница 23: ...and RS232 Pinout Pin Signal mark Description 1 D In Out 2 D In Out 3 GND Ground common with RS232 Table 5 Connection of RS485 Pin Signal mark Description 3 GND Ground common with RS485 4 RXD Received Data 5 TXD Transmit Data 6 RTS Request to Send 7 CTS Clear to Send Table 6 Connection of RS232 The serial interfaces are not eletrically isolated from the router 17 LUCOM GmbH Flößaustr 22a 90763 Fürt...

Страница 24: ...nication in progress on radio channel SIG Green On Blinking Fast blinking Good signal Fair signal Poor signal TECH Green On Blinking Fast blinking 4G technology is used by the active SIM 3G technology is used by the active SIM 2G technology is used by the active SIM SIM Green On Blinking Fast blinking SIM1 is selected SIM2 is selected SIM card problem missing SIM or PIN not entered ETH0 ETH1 Green...

Страница 25: ...p due to the bad configura tion turn off the router disconnect the power supply Push and hold the RST button turn on the router and hold the RST button for at least 10 seconds This will return the configuration of the router to the default one It is recommended to back up the settings of the router configuration prior to performing the factory reset of the router Note that resetting of the router ...

Страница 26: ...face Press the RST button and hold il less than 4 sec onds Factory Reset Restores the default configuration and reboots the router Hold the RST button for more than 4 seconds If it does not help router does not start at all turn off the router power supply Push and hold the RST button then turn on the router and hold the RST button for more than 10 seconds Table 8 Overview of Router Reboot and Res...

Страница 27: ...ssword Log in to the web interface by the root user and his password If logged in successfully the user will have access to the router web interface see Figure 13 See the configuration manual 2 of the router for a detailed description and examples of the router configuration After logging on to the device for the first time we strongly recommend changing the default password due to security reason...

Страница 28: ...rface A detailed description of the router settings in the web interface can be found in the configura tion manual of the router 22 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 29: ...placeable Consumption Idle Average Maximum 2 W 2 4 W 2 6 W Dimensions of device w o clip 130 x 95 x 25 mm DIN rail clip optional part specification DIN 35 mm EN 60715 Weight Box w o clip 345 g Antenna connectors SMA connector for LTE 50 Ω Interfaces ETH0 ETH1 PWR I O SERIAL RJ 45 socket for 10 100 Mbps Ethernet RJ 45 socket for 10 100 Mbps Ethernet 6 pin socket for power supply and I O interfaces ...

Страница 30: ...MC EN 301 489 1 EN 301 489 52 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 6 2 EN 55032 Safety IEC 62368 1 AS NZS 62368 1 IEEE 802 3 National CE UKCA compliant Environmental REACH RoHS3 and WEEE compliant Table 10 Standards and Regulations 24 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 31: ...L3 10 V 0 15 80 MHz 80 AM 1kHz L3 10 V 0 15 80 MHz 80 AM 1kHz L3 10 V 0 15 80 MHz 80 AM 1kHz L3 10 V 0 15 80 MHz 80 AM 1kHz L3 Radiated emission EN 55032 Enclosure Class B 30 MHz 1 GHz 1 GHz 6 GHz Conducted emission EN 55032 DC power port Ethernet ports Serial ports RS232 RS485 Class B 150 kHz 30 MHz Class B 150 kHz 30 MHz Class B 150 kHz 30 MHz Class B 150 kHz 30 MHz Class B 150 kHz 30 MHz Dry he...

Страница 32: ...es up to 589 Kbps DL 1119 Kbps UL Cat NB frequencies B31 450 MHz B12 B13 B28 B85 700 MHz B20 800 MHz B5 B18 B19 B26 850 MHz B8 900 MHz B4 B66 1700 MHz B3 1800 MHz B2 B25 1900 MHz B1 2100 MHz Cat NB bit rates up to 127 Kbps DL 158 5 Kbps UL EDGE GPRS parameters Supported frequencies B5 850 MHz B8 900 MHz B3 1800 MHz B2 1900 MHz Bit rates up to 296 kbps DL 236 8 kbps UL Table 12 Technical Parameters...

Страница 33: ...cteristics of Binary Inputs The maximum binary output load is 100 mA at 9 48 V 4 6 System Configuration The main parametes of the system are listed in Table 14 Other technical parameters CPU architecture ARM926EJ S CPU frequency 600 MHz CPU power 4 72 DMIPS MHz Flash memory 64 MB NOR Flash 12 MB for Router Apps 2 MB for customer data RAM size 128 MB Watchdog HW Watchdog RTC Battery Backup RTC Tabl...

Страница 34: ...h you will need to use a directional antenna For proper operation the signal levels have to be good Try to enable automatic ping from the router which will check the connection when there are no data running and in the case of a failed ping restart the connection This can be done on the Mobile WAN Configuration page in the router in the Check connection section Enable bind option is to ensure the ...

Страница 35: ...by accessing remotely to the router s Web interface The operator may not provide the address of DNS server and without DNS server s address it is impossible to connect to the dyndns org server The following mes sages will be shown in the System Log DynDNS daemon started Error resolving hostname no such file or directory Connect to DynDNS server failed L2TP or IPSec isn t establishing Check the Sys...

Страница 36: ...files to from the router If having troubles with FTP on v2 routers make sure you have FTP enabled Configuration section Services FTP Then you can connect with any client on port 21 with name and password same as for the Web interface If having troubles with SFTP make sure you have SSH enabled Configuration section Services SSH Then you can connect with any client on port 22 with name and password ...

Страница 37: ...antech B B SmartWorx 707 Dayton Road Ottawa IL 61350 USA Phone 1 800 346 3119 Monday Friday 7 a m to 5 30 p m CST Fax 1 815 433 5109 E mail support advantech bb com Web www advantech bb com Customer Support for Asia Phone 886 2 2792 7818 1299 Monday Friday 9 a m to 5 30 p m UTC 8 Fax 886 2 2794 7327 E mail icg support advantech com tw Web www advantech com 31 LUCOM GmbH Flößaustr 22a 90763 Fürth T...

Страница 38: ...ect the router against dust moisture and high temperature Only routers with appropriate certification and labelling should be used in locations where flammable and explosive materials are present including gas stations chemical plants or locations in which explosives are used We remind users of the duty to observe the restrictions concerning the utilization of radio devices at such places Switch o...

Страница 39: ...ains high quality materials and components which can be recycled At the end of it s life this pro duct MUST NOT be mixed with other commercial waste for disposal The device contains a battery Remove the battery from the device before disposal The battery in the device needs to be disposed of apart accordingly Check the terms and conditions of your supplier for disposal information 33 LUCOM GmbH Fl...

Страница 40: ... 2 Configuration Manual for v2i Platform EP Product related documents and applications can be obtained on Engineering Portal at https icr advantech cz download address 34 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 41: ...o 1206 We Advantech Czech s r o declare that the radio equipment narrated in this user s manual complies with Directive 2014 53 EU The full text of the EU Declaration of Conformity is available at the following internet address icr advantech cz eudoc LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Отзывы: