ICR-2412
4.5
Parameters of I/O Ports
Electrical characteristics of the binary inputs are in Table
. Status of the binary input is
reported in the GUI on
General Status
page or can be retrieved in the Shell via
io get bin0
command.
get
command output
Voltage
Web interface status
0
≤
0.8 V (0.5 mA))
On
1
≥
2 V
Off
Table 13: Electrical Characteristics of Binary Inputs
The maximum binary output load is
100 mA
at
9 – 48 V
.
4.6
System Configuration
The main parametes of the system are listed in Table
Other technical parameters
CPU architecture
ARM926EJ-S
CPU frequency
600 MHz
CPU power
4,72 DMIPS/MHz
Flash memory
64 MB NOR Flash
•
12 MB for Router Apps
•
2 MB for customer data
RAM size
128 MB
Watchdog
HW Watchdog
RTC
Battery Backup RTC
Table 14: System Configuration
27
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: [email protected] — www.lucom.de
www