background image

35

FWA-5070 User Manual

Chapter 5

B

IOS Settings

5.2.2.3

Trusted Computing

Please note that Trusted Computing support is disabled by default in the factory
defaults to save system boot time. If disabled, the Trusted Computing Menu will not
display any status information.
 

Figure 5.7 Platform Setup: Trusted Computing

Table 5.3: USB Configuration Menu

Group

Setup item

Access / Options

Description

None

USB Support

Enabled
Disabled

Enables or disables the support for 
USB. If disabled, the USB EHCI con-
troller will not be initialized by the 
BIOS.

Legacy USB Sup-
port

Auto
Enabled
Disabled

Enables legacy support over USB to 
support Keyboard and Mouse 

XHCI Hand-Off

Enabled
Disabled

Controls the hand off of XHCI owner-
ship from BIOS to OS at boot time. 

Port 60/64 
Emulation

Enabled
Disabled

Enables I/O port 60h/64h emulation 
support

USB 
hardware 
delay 

USB transfer 
time-out

1sec / 5sec / 
10sec / 20sec

The time-out value for Control, Bulk, 
and Interrupt transfers.

Device Reset 
time-out

10sec / 20sec / 
30sec / 40sec

Time Out for a device to Reset

Device power-up 
delay

Auto
Manual

Maximum time the device will take 
before it properly reports itself to the 
Host Controller.

Device power-up 
delay

5

Содержание FWA-5070

Страница 1: ...User Manual FWA 5070 1U RACKMOUNT NETWORK APPLIANCE...

Страница 2: ...ty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defe...

Страница 3: ...uer d interf rences nuisibles 2 Cet appareil doit accepter toute interf rence re ue y compris les interf rences susceptibles de provoquer un fonctionnement ind sirable Remarque Cet quipement a t test...

Страница 4: ...software etc A complete description of the problem The exact wording of any error messages 3 For more information please contact ncg advantech com or visit www advan tech com nc Warnings Cautions and...

Страница 5: ...pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If one of...

Страница 6: ...ne surtension transit oire 12 Ne versez jamais de liquide dans une ouverture Cela pourrait provoquer un incendie ou un choc lectrique 13 N ouvrez jamais l quipement Pour des raisons de s curit l quipe...

Страница 7: ...vii FWA 5070 User Manual 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 C 20 C 4 F 40 C 60 C 140 F 16 17 IEC 704 1 1982 70 18 IEC 704 1 CCC A...

Страница 8: ...FWA 5070 User Manual viii...

Страница 9: ...mper Setting 9 2 4 Switch Setting 10 Chapter 3 Installation Guide 11 3 1 CPU Heatsink 12 Figure 3 1 CPU installation 12 3 2 Memory 12 Figure 3 2 DRAM installation 13 3 3 SATA HDD SSD 13 Figure 3 3 HDD...

Страница 10: ...Configuration Menu 45 Figure 5 15Chipset Processor Configuration Menu 46 Table 5 10 Processor Configuration Menu 46 Figure 5 16North Bridge Configuration Menu 48 Table 5 11 Northbridge Configuration...

Страница 11: ...FWA 5070 User Manual Figure 5 29CSM16 Configuration 65 5 2 6 Security Setup 66 Figure 5 30Administrator Setup 66 5 2 7 Save Exit Menu 67 Figure 5 31Save Exit Menu 67 Table 5 22 Save Exit Menu Options...

Страница 12: ...FWA 5070 User Manual xii...

Страница 13: ...Chapter 1 1 Specifications...

Страница 14: ...0 AT 1GbE 2 x 10 100 1000 Mbps RJ45 via Intel i210 AT chip 10GbE N A 2 x 10G SFP via Intel C625 LAN bypass LAN bypass is supported by NMC Expansion PCIe 1x FH HL PCIe gen3 x16 1x FH HL PCIe gen3 x8 NM...

Страница 15: ...chanical Construction Steel Mounting 1U rackmount Dimensions W x H x D 438 x 44 x 550 mm Weight 15 KG OS Support Linux CentOS Red Hat Ubuntu Advantech S W Packages System diagnostic tool and quick sta...

Страница 16: ...FWA 5070 User Manual 4 1 2 1 2 LED Button Figure 1 2 LED Button 1 2 2 REAR VIEW Figure 1 3 Rear view 1 3 System layout System layout as below Figure 1 4 System Layout...

Страница 17: ...5 FWA 5070 User Manual Chapter 1 Specifications 1 4 Block Diagram Figure 1 5 Block Diagram...

Страница 18: ...FWA 5070 User Manual 6...

Страница 19: ...Chapter 2 2 Connector List and Jumper and Switch Setting...

Страница 20: ...and P3V3 for NAMB 6070HDD4BP CN48 Board to Board Connector For NAMB 6070MGT CN22 PCIE 8 Connector For Advantech NMC module CN23 PCIE 8 Connector For Advantech NMC module CN24 PCIE 8 Connector For Adva...

Страница 21: ...nnector CN19 Intrusion Switch Detect system case is opened or closed CN39 Front Panel Connector Button SMBus LED CN29 XDP Connector CN30 JTAG CN31 JTAG CN40 JTAG CN44 External Programming BMC Flash Co...

Страница 22: ...ce JP10 1 2 Default CF1 enable 2 3 CN46 enable JP12 Open Default Normal Short External VR Programming Mode Debug Location PIN Function SW2 1 OFF Default Normal 1 ON Reset BMC 2 OFF Default Normal 2 ON...

Страница 23: ...Chapter 3 3 Installation Guide...

Страница 24: ...low Intel s instruction to install the Xeon CPU on heatsink https www intel com content www us en support articles 000023869 processors intel xeon processors html Step 2 Tighten screws on heatsink sti...

Страница 25: ...lation 3 3 SATA HDD SSD FWA 5020 supports 2 2 5 SATA HDD SSD 1 M 2 2280 SSD and 1 mSATA 1 HDD SSD Installation Remove HDD bracket and install HDD SSD on the bracket Note A DRAM channel is separated fo...

Страница 26: ...or mSATA on motherboard Figure 3 4 M 2 and mSATA installation 3 4 PCIe FWA 5070 reserves 1 x PCIe slot for support different kinds of PCIe add on cards like low profile and full high half length card...

Страница 27: ...allation Guide Figure 3 5 PCIe installation 3 5 Slide Rail Installation Guide 3 5 1 Overview This guide is for FWA 5070 s slide rail Advantech PN 9680016905 it s an optional kit so please contact Adva...

Страница 28: ...FWA 5070 User Manual 16 Step 2 Step 3...

Страница 29: ...17 FWA 5070 User Manual Chapter 3 Installation Guide Step 4 Step 5...

Страница 30: ...FWA 5070 User Manual 18 Step 6 Step 7...

Страница 31: ...twork Mezzanine Cards NMCs in the front panel Insert NMC alone with guiding rail and fasten with thumb screws Figure 3 6 NMC installation 3 7 Install remove Power Supply component Power supply unit is...

Страница 32: ...FWA 5070 User Manual 20...

Страница 33: ...Chapter 4 4 Operation...

Страница 34: ...force the server to enter standby mode This method forces the server to enter standby mode without properly exiting applications and the OS If an application stops responding you can use this method t...

Страница 35: ...bled and then go to item of BIOS Advanced CSM Parameters Network to enable PXE ROM function set it as Legacy IPV4 PXE function 3 Save BIOS and reboot system The BIOS will show Checking Media Pres ence...

Страница 36: ...le file from the boot server Similarly booting Linux over network is usually a two stage process In the first step a boot loader such a grub or mini OS such as SysLinux are loaded via PXE from the boo...

Страница 37: ...as boot server Setting up such a boot server implies a couple of steps How to guides for setting up Linux as PXE boot server are available on the internet https www debianadministration org article 47...

Страница 38: ...FWA 5070 User Manual 26...

Страница 39: ...Chapter 5 5 BIOS Settings...

Страница 40: ...guration parameters when shipped by Advantech referred to as Optimized Defaults or factory defaults The user can change BIOS settings via the setup menu either temporarily or permanently by saving the...

Страница 41: ...in elements as shown below The menu bar displays the selectable menu pages as tabs The parameter window dis plays and allows configuration of the settings available in a given menu page or a submenu t...

Страница 42: ...summary of system and BIOS configuration and status information The fields on this page are read only except for the System Date and Time setting Table 5 1 Table 7 BIOS Setup Main Menu Group Setup it...

Страница 43: ...ing manufacturing process accord ing to factory s local time zone You may need to update system time to reflect the desired time zone when you receive the unit System Language Display only Selects the...

Страница 44: ...the screen such as the Trusted Computing Configuration to go to the sub menu for that item Users can dis play a Platform BIOS Setup option by highlighting it using the Arrow keys The Platform BIOS Se...

Страница 45: ...orm Setup COM0 Console Redirection Menu Items Setup item Access Options Description Console Redirection Disabled Enabled Disabled Enabled Console Redirection Serial Console Port COM0 Serial Console Po...

Страница 46: ...and sent as text messages to a remote server Resolution 100x31 Disabled Enabled Enables or disables extended terminal resolution Legacy OS redirection 80x24 80x 25 When using Legacy OS this item speci...

Страница 47: ...CI con troller will not be initialized by the BIOS Legacy USB Sup port Auto Enabled Disabled Enables legacy support over USB to support Keyboard and Mouse XHCI Hand Off Enabled Disabled Controls the h...

Страница 48: ...ith TPM2 0 Table 5 4 Trusted Computing Menu Group Setup item Access Options Description Configuration Security Device Sup Auto TPM1 2 TPM2 0 Auto will support both or set the support for the TPM 1 2 o...

Страница 49: ...in order to change State of Security Device Platform Hierarchy Enable Disable Enable or Disable Platform Hierar chy Storage Hierarchy Enable Disable Enable or Disable Storage Hierar chy Endorsement Hi...

Страница 50: ...show Security Device TCG EFI protocol and INT1A interface will not be available TPM State Enable Disable Enable Disable Security Device NOTE Your Computer will reboot dur ing restart in order to chang...

Страница 51: ...nual Chapter 5 BIOS Settings 5 2 2 5 H W Monitor This sub menu allows you to see all the H W monitor items detected by the BIOS without BMC to know all current system health status Figure 5 10 Platfor...

Страница 52: ...rough mode This applies for all PCIe devices Figure 5 11 Platform Setup Virtualization Table 5 7 Virtualization Menu Group Setup item Access Options Description None Intel Virtualization Enable Disabl...

Страница 53: ...This sub menu allows you to change the settings used for related CPU utilization set ting The default configuration for CPU was optimized setting for getting better perfor mance for networking so it i...

Страница 54: ...age C state limit setting is deep C state support Energy Performance Tuning OS Controls EPB BIOS Controls EPB Selects whether BIOS or Operat ing System chooses energy per formance bias tuning WHEA Sup...

Страница 55: ...ss Devices None Slot1 1 LBP Control Slot1 2 LBP Control Select which Slot to control Lan Bypass Config Lan Bypass Segments Segment1 Segment2 Segment3 Segment4 Select which segment of NMC device to con...

Страница 56: ...Dog Time Out Connect Disconnect Bypass Select the action of Lan Bypass for NMC When watch dog time out External Trigger Status Display only The current Status of Lan Bypass in External Trigger Extern...

Страница 57: ...e related functionality is split over the CPU and PCH portions of the SoC Similarly the terms South Bridge and North Bridge are legacy terms and do not represent the silicon implementation any more Ho...

Страница 58: ...15 Chipset Processor Configuration Menu Table 5 10 Processor Configuration Menu Group Setup item Access Options Description Socket0 CPU information CPU signature Display only Displays information on t...

Страница 59: ...ntel TXT Support Enable Disable Enable Disable Intel TXT Hardware Prefetcher Enable Disable Enable or disable Hardware Prefetcher feature MLC Streamer Prefetcher MSR 1A4h Bit 0 Adjacent Cache Line Pre...

Страница 60: ...070 User Manual 48 5 2 3 2 Hardware Setup North Bridge Configuration This menu allows the configuration of the memory controller and related features of the SoC Figure 5 16 North Bridge Configuration...

Страница 61: ...rrored Memory Rank Sparing Enable Disable Memory Rank Sparing enable disable Numa Enable Disable Enable or Disable Non uni form Memory Access NUMA IMC Interleaving Auto 1 way Interleave 2 way Interlea...

Страница 62: ...Hardware Setup PCI Subsystem Table 5 12 Hardware Setup PCI Subsystem Menu Items Group Setup item Access Options Description Socket 0 PCIe port control PCIe Hot Plug Enabled Disable Enable PCIe hot pl...

Страница 63: ...sable Intel Volume Management Device Technology on specific root port PORT 1D Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Change PCI Express Devices Set tings PORT 1D VMD Enabled Disable...

Страница 64: ...Volume Management Device Technology on specific root port PORT 3C Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Change PCI Express Devices Set tings PORT 3C VMD Enabled Disable Enable Disa...

Страница 65: ...on Menu Items Group Setup item Access Options Description None Isoc Enabled Disable Enable disable ISOC Link Speed Mode Fast Slow Select UPI link speed as either the POR speed Fast or default speed sl...

Страница 66: ...e Setup South Bridge configuration Menu Items Group Setup item Access Options Description SATA Configuration N A Select sub menu USB Configuration N A Select sub menu ACPI Settings N A Select sub menu...

Страница 67: ...ly SATA Port3 Display only SATA Port4 Display only SATA Port5 Display only SATA Port6 Display only SATA Port7 Display only sSATA Port1 Display only sSATA Port5 Display only SATA Mode AHCI RAID 1 AHCI...

Страница 68: ...ggable SATA Hot Plug Port 5 Enabled Disabled Designates this port as Hot Pluggable SATA Hot Plug Port 6 Enabled Disabled Designates this port as Hot Pluggable SATA Hot Plug Port 7 Enabled Disabled Des...

Страница 69: ...nable Disable this USB Physical Connector physical port USB Port 2 Disable Enabled Disabled Enable Disable this USB Physical Connector physical port USB Port 3 Disable Enabled Disabled Enable Disable...

Страница 70: ...Enable ACPI Auto Configuration Enabled Disabled Enable or disable BIOS ACPI auto configuration Enable Hibernation Enabled Disabled Enable the system ability to hiber nate OS S4 sleep state this option...

Страница 71: ...tings for the Runtime error logging configuration Figure 5 23 Hardware Setup Runtime Error logging configuration Table 5 18 Hardware Setup Runtime Error logging Menu Items Group Setup item Access Opti...

Страница 72: ...FWA 5070 User Manual 60 5 2 3 9 NVMe configuration This menu contains settings for NVMe controller and Drive information Figure 5 24 NVMe configuration...

Страница 73: ...er Manual Chapter 5 BIOS Settings 5 2 3 10 Intel VROC for Volume Management Device Configuration This menu contains settings for Intel VMD for Volume Management Device Config uration Figure 5 25 VROC...

Страница 74: ...rocess OS Watchdog Timer Enable Disable If enabled starts a BIOS timer which can only be shut off by Management Software after the OS loads Helps determine that the OS suc cessfully loaded or follows...

Страница 75: ...Boot Configuration Table 5 20 Boot Configuration Feature Default Description Setup Prompt Timeout 1 Number of seconds to wait for setup activation key Bootup NumLock State On Select the keyboard NumLo...

Страница 76: ...Menu Group Setup item Access Options Description None CSM Support Enabled Disabled Enables or disables the Compatibility Support Module Boot option filter UEFI and Legacy Legacy Only UEFI Only This i...

Страница 77: ...16 Configuration Group Setup item Access Options Description None GateA20 Active Upon Request Always This items is useful when RT code is executed above 1MB When this is set as UPON RQUEST GA20 can be...

Страница 78: ...r the Setup program Figure 5 30 Administrator Setup Note If set the Password Check is Setup then this only limits access to Setup and is only asked for when entering Setup If set the Password Check is...

Страница 79: ...setup without saving any changes Save Changes and Reset Reset system after saving the changes Does not update User Defaults Discard Changes and Reset Reset system without saving the changes Save Optio...

Страница 80: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...

Отзывы: