EKI-7710 Series User Manual
117
The ensuing table for
Local Users
settings are informational only: User Name, Pass-
word Type, Privilege Type and
Delete
(click to delete the desired user account).
4.11.7
Reset System
To access this page, click
Tools
>
Reset System
.
Click
Restore
to have all configuration parameters reset to their factory default val-
ues. All changes that have been made will be lost, even if you have issued a save.
Reset settings take effect after a system reboot.
4.11.8
Reboot Device
To access this page, click
Tools
>
Reboot Device
.
Click
Reboot
to reboot the switch. Any configuration changes you have made since
the last time you issued a save will be lost.
4.12
Modbus/TCP Mapping
The data map addresses of Advantech switches shown in the following table start
from Modbus address 30001 for function code 4.
In the given example, the address offset 0x1000 (hex) equals Modbus address
34097, while the address offset 0x1100 (hex) equals Modbus address 34353.
The information given by the Advantech is shown in hex mode.
4.12.1
Modbus/TCP Mapping Table
Privilege Type
Click the drop-down menu to designate privilege authority for the user
entry:
Admin
or
User
.
Apply
Click
Apply
to create a new user account.
Item
Description
Catelog
Name
Data Type
Interpretation
Address
Offset (Hex)
Address
3X
Description
System Info
Vendor ID =
0x‘13FE
1 word 16 bits HEX
0x0000
30001
Vendor ID = 0x13FE
Unit ID = 0xFF 1 word 16 bits HEX
0x0001
30002
Unit ID = 0xFF
Product Code 1 word 16 bits HEX
0x0002
30003
Product Code
Содержание EKI-7710 Series
Страница 1: ...User Manual EKI 7710 Series 8FE 2G 8GE 2G Combo port L2 Managed Switch...
Страница 14: ...Chapter 1 1Product Overview...
Страница 23: ...Chapter 2 2Switch Installation...
Страница 40: ...Chapter 3 3Configuration Utility...
Страница 45: ...32 EKI 7710 Series User Manual 4 Click OK on the login screen to log in The main interface displays...
Страница 46: ...Chapter 4 4Managing Switch...
Страница 154: ...Chapter 5 5Troubleshooting...