background image

EDGE Industrial Router

ER75i v2

USER MANUAL

LUCOM GmbH    —   Flößaustr. 22a   —   90763 Fürth   —   Tel.:  +49 911/ 957 606 00   —   E-Mail: [email protected]   —   www.lucom.de

www

.lucom.de

Содержание EDGE ER75i v2

Страница 1: ...EDGE Industrial Router ER75i v2 USER MANUAL 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 2: ...ystem without written consent Information in this manual is subject to change without notice and does not represent a commitment on the part of Advantech Advantech Czech s r o shall not be liable for incidental or consequential damages resulting from the furnish ing performance or use of this manual All brand names used in this manual are the registered trademarks of their respective owners The us...

Страница 3: ... codes under GPL licence are available free of charge by sending an email to techSupport advantech bb com Please see http ep advantech bb cz devzone for more information Advantech Czech s r o Sokolska 71 562 04 Usti nad Orlici Czech Republic Document No MAN 0013 EN revision from May 19 2020 Released in the Czech Republic i 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail ...

Страница 4: ...rail 14 5 7 Description of the front panel 15 5 7 1 Status indication 16 5 7 2 Power connector PWR 17 5 7 3 Antenna connector ANT and AUX 18 5 7 4 SIM card reader 19 5 7 5 Ethernet Port ETH 20 5 7 6 PORT1 21 5 7 7 PORT2 21 5 7 8 USB Port 22 5 7 9 I O Port 23 5 7 10 Reset 25 6 First Use 26 6 1 Connecting the router before first use 26 6 2 Start 27 6 3 Configuration 27 6 3 1 Configuration over web b...

Страница 5: ...s of I O port 30 7 6 Technical parameters of expansion port 30 8 Related Documents 31 9 Troubleshooting 32 9 1 FAQ 32 10 Customers Support 35 10 1 Customer Support for NAM 35 10 2 Customer Support for Europe 35 10 3 Customer Support for Asia 35 iii 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 6: ...of connectors metal 13 17 Default position of plastic and metal DIN rail clip 14 18 Removal from the DIN rail 14 19 Front panel ER75i v2F 15 20 Power connector 17 21 Connection of power supply 17 22 Connecting of the antenna 18 23 Ejected SIM holder 19 24 Ethernet connector 20 25 Connection of ethernet cable 20 26 PORT1 cable connection 21 27 PORT2 cable connection 22 28 USB connector 22 29 I O co...

Страница 7: ...of power connector 17 11 Connection of Ethernet connector 20 12 Connection of USB connector 22 13 Connection of I O port 23 14 Description of reset and restart router 25 15 Basic parameters 29 16 Standards and regulations 29 17 Technical parameters of module 30 18 Other technical parameters 30 19 Technical parameters of I O port 30 1 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606...

Страница 8: ...ters with appropriate certification and labelling should be used in locations where flammable and explosive materials are present including gas stations chemical plants or locations in which explosives are used We remind users of the duty to observe the restrictions concerning the utilization of radio devices at such places Switch off the router when traveling by plane Utilization of the router on...

Страница 9: ...ains high quality materials and components which can be recycled At the end of it s life this pro duct MUST NOT be mixed with other commercial waste for disposal The device contains the battery Remove the battery from the device before disposal The battery in the device needs to be disposed apart accordingly Check the terms and conditions of your supplier for disposal information 3 29 01 21 LUCOM ...

Страница 10: ...e requirements of the customer Configuration is done via web interface protected by password EDGE industrial router supports creation of VPN tunnels using technologies IPsec OpenVPN and L2TP to ensure safe communication Web interface provides detail statistics about the wireless router activi ties signal strength detailed log etc Router supports functions DHCP NAT NAT T DynDNS NTP VRRP control by ...

Страница 11: ...rature range for power supply is reduced to 0 C to 40 C As optional accessories can also be supplied the following expansion ports one for Basic version or two for Full version RS232 RS485 422 MBUS ETHERNET CNT SWITCH WIFI WMBUS or SDH Separation columns for mounting expansion boards are included 5 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom d...

Страница 12: ... x 1 x ER75i v2B SL Metal 1 x 1 x 1 x 1 x 1 x ER75i v2F Plastic 1 x 1 x 1 x 1 x 1 x 1 x 1 x ER75i v2F SL Metal 1 x 1 x 1 x 1 x 1 x 1 x 1 x Table 1 Router versions Figure 2 Front panel ER75i v2B Figure 3 Front panel ER75i v2F Figure 4 Front panel ER75i v2F with WiFi Figure 5 Front panel ER75i v2B SL Figure 6 Front panel ER75i v2F SL Figure 7 Front panel ER75i v2F SL with WiFi 6 29 01 21 LUCOM GmbH ...

Страница 13: ...sion in the metal box ER75i v2F BB ER2F51vw1y Full version in the plastic box ER75i v2F SL BB ER2F51vw2y Full version in the metal box Table 2 Delivery identification Figure 8 Label examples 1 Order codes are described in detail in a separate chapter 7 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 14: ... following structure BB ER2F51vwxy where v port 1 w port 2 x type of router box y type of power supply Letter v port 1 Port type Letter v incode none 0 ETH 1 RS232 2 RS485 3 RS422 4 MBUS 5 CNT 6 SWITCH 92 Table 3 Type of port 1 2 Occupies both port 1 and port 2 Available for full version only 8 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de ww...

Страница 15: ...he router box Type of router box Letter x in code Plastic 1 Metal 2 Table 5 Type of router box Letter y type of the power supply Type of power supply Letter y in code none 0 Europe 1 UK Ireland 2 Australia 3 USA 4 Table 6 Type of power supply 9 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 16: ...ader 2x ETH 1x USB 1x I O metal Europe BB ER2F514010 EDGE module 2x SIM reader 1x ETH 1x USB 1x I O 1x RS422 plastic none BB ER2F516322 EDGE module 2x SIM reader 1x ETH 1x USB 1x I O 1x CNT 4x BI 1x RS485 metal UK Ireland Table 7 Order code examples You can use the order codes configurator on the www bb smartcellular eu webpages 10 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 0...

Страница 17: ... box Figure 9 Basic dimensions of plastic box bottom and front view 5 4 2 Metal box Figure 10 Basic dimensions of metal box bottom and front view 11 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 18: ...to EN 60439 1 ed 2 00 A1 04 If the negative pole of the router is grounded there is no protection against reversed polarity Compliance of EN 60439 1 ed 2 00 A1 04 specification it is necessary to observe next assembly of the router to the switch board For whip antennas we recommend to observe a distance of 6 cm from cables and metal surfaces on every side due to the elimination of interference Whi...

Страница 19: ...y cables with reticular tension 230 V 50 Hz Figure 13 Cable routing plastic Figure 14 Cable routing metal Sufficient space must be left in front of individual connectors for handling of cables Figure 15 Space in front of connectors plastic Figure 16 Space in front of connectors metal For correct function of the router we recommend to use in the switch board earth bonding distribution frame for gro...

Страница 20: ...anging the position of the DIN rail clip tighten the screws with max 0 4 Nm torque Figure 17 Default position of plastic and metal DIN rail clip To remove the router from the DIN rail push the router down lightly so the bottom part of the DIN rail clip hitched to the DIN rail gets out of the rail and then pull out the bottom part of the router away from the DIN rail Figure 18 Removal from the DIN ...

Страница 21: ...422 MBUS SWITCH WIFI WMBUS or SDH only FULL versions ANT SMA Connector for main antenna USB USB A Host Connector for connection of USB devices to the router Sup ports devices with PL 2303 and FTDI USB RS232 converters I O 3 pin Connector for connection of the binary input and output SIM1 Holder for the first SIM card SIM2 Holder for the second SIM card only FULL versions Table 8 Front panel descri...

Страница 22: ...dBm to 113 dBm or differ ence between neighbours cells is smaller than 3 dBm USR Yellow Function of this LED diode can be selected by user OUT Green On Binary output active IN Green On Binary input active ETH Green On Off Selected 100 Mbit s Selected 10 Mbit s ETH Yellow On Blinking Off The network cable is connected Data transmission The network cable is not connected PORT Green Depends on the ex...

Страница 23: ... The power consumption during receiving is 2 0 W The peak power consumption during data sending is 5 5 W However values of consumption can be increased if some expansion port is equipped For correct operation it is necessary that the power source is able to supply a peak current of 1 2 A Circuit example Figure 21 Connection of power supply The positive pole VCC is marked by a red socket on the pow...

Страница 24: ...t operate without connected main antenna marked as ANT ANT connector is used to connect the main antenna If WIFI or WMBUS expansion port is equipped on customer s request there is also available AUX antenna connector for connecting corresponding antenna The antenna is connected by screwing this antenna to the SMA connector on the front panel of the router see the figure below Figure 22 Connecting ...

Страница 25: ...cess Point Name Supported type of SIM cards Mini SIM 2FF dimensions 25 0 x 15 0 x 0 76 mm Changing the SIM card Before handling of the SIM card disconnect the router from power supply Press the small yellow button to eject the reader holder Insert the SIM card into the reader holder and slide it in the reader see the figure below Figure 23 Ejected SIM holder 19 29 01 21 LUCOM GmbH Flößaustr 22a 90...

Страница 26: ...ative pole Input Output 3 RXD Receive Data positive pole Input Output 4 5 6 RXD Receive Data negative pole Input Output 7 8 Table 11 Connection of Ethernet connector Figure 24 Ethernet connector ETH port is not PoE Power over Ethernet compatible Plug Ethernet cable into the RJ45 connector labeled as ETH see the figure below Figure 25 Connection of ethernet cable 20 29 01 21 LUCOM GmbH Flößaustr 22...

Страница 27: ...45 connector labeled as PORT1 see the figure below Figure 26 PORT1 cable connection 5 7 7 PORT2 The PORT2 is equipped on customer s request with one of the offered expansion ports RS232 RS485 RS422 MBUS SDH SWITCH together with PORT1 WIFI WMBUS PORT2 is available only in the Full version of the router Description and examples of expan sion ports connection can be found in user s guide for correspo...

Страница 28: ... 3 USB data USB data signal positive pole Input Output 4 GND Negative pole of DC supply voltage Table 12 Connection of USB connector Figure 28 USB connector Mounting USB flash drive to the system To use the USB flash drive in the Linux system of the router it is necessary to mount it Use dmesg command to see the name of recently connected device E g sda sda1 and then use mount command Example moun...

Страница 29: ...put and control setting binary output Binary output is not switched to ground in the default configuration Maximum load binary output is 30 V 100 mA The constant current supplied by the binary input is 3 mA Connect I O cable into the I O connector on the front panel of the router and tighten locking screws see the figure below Figure 30 Connection of I O cable 23 29 01 21 LUCOM GmbH Flößaustr 22a ...

Страница 30: ...scribing connection of binary input and output to the router Figure 31 Connection of input and output to the router 24 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 31: ...nfiguration of the router see Configuration manual for v2 routers because reset of the router sets the configuration to the default state It is important to distinguish between reset and reboot the router Action Router behavior Invoking events Reboot Turn off and then turn on router Disconnect and connect the power Press the Reboot button in the web configuration Reset Restore default configuratio...

Страница 32: ...ch are required to run your applications Don t forget to insert SIM card The router can not operate without connected antenna SIM card and power supply If the antenna is not connected router can be damaged Figure 33 Router connection 26 29 01 21 LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 33: ...A 6 3 Configuration If no SIM card is inserted in the router it is not possible to operate Inserted SIM card must have activated data transmission 6 3 1 Configuration over web browser For status monitoring configuration and administration of the router is available a web interface which can be accessed by entering the IP address of the router into the web browser The default IP address of the rout...

Страница 34: ... can be done by accessing the device through the Secure Shell SSH or the Telnet protocol The default IP address of the device is 192 168 1 1 Standard TCP ports are used 22 for the SSH and 23 for the Telnet Please note that access is permitted for users of the admin role only and that the Telnet protocol is disabled by default For a detailed description of SSH and Telnet configuration see the Confi...

Страница 35: ... only for WiFi User interface ETH USB PORT1 PORT2 Ethernet 10 100 Mbps USB 2 0 type A host On customer s request On customer s request Table 15 Basic parameters 7 2 Standards and regulations The router complies with the following standards and regulations Standards and regulations Telecom and emission ETSI EN 301 511 V12 5 1 2017 03 ETSI EN 300 328 V2 1 1 2016 11 ETSI EN 300 220 2 V3 1 1 2017 02 E...

Страница 36: ... 25 DMIPS per MHz Flash memory 16 MB DDR SDRAM RAM 64 MB M RAM 128 kB Table 18 Other technical parameters 7 5 Technical parameters of I O port Binary input and output Input Output Binary input Binary output Reed contact with trigger level 1 3 up to 1 4 V 100 mA max 30 V Table 19 Technical parameters of I O port 7 6 Technical parameters of expansion port Technical parameters of expansion ports are ...

Страница 37: ...anual Expansion port CNT 7 Advantech Czech User s manual Expansion port ETH 8 Advantech Czech User s manual Expansion port SWITCH 9 Advantech Czech User s manual Expansion port WIFI 10 Advantech Czech User s manual Expansion port WMBUS 11 Advantech Czech User s manual Expansion port SD 12 Advantech Czech Application note Expansion port mounting 13 Advantech Czech Application note Programmer guide ...

Страница 38: ...he Ethernet interface of the router Available on LAN Configuration page in the router Mobile WAN connection fails Check the signal power Mobile WAN status page If the signal power is weak you will have to use a better antenna If the neighbouring cells have a similar signal strength you will need to use a directional antenna For proper operation the signal levels have to be good Try to enable autom...

Страница 39: ... using NAT or a firewall You can verify NAT using ping to your server with static address and then compare with router s IP address You can verify a Firewall by accessing remotely to the router s Web interface The operator may not provide the address of DNS server and without DNS server s address it is impossible to connect to the dyndns org server The following mes sages will be shown in the Syst...

Страница 40: ...s to from the router If having troubles with FTP on v2 routers make sure you have FTP enabled Configuration section Services FTP Then you can connect with any client on port 21 with name and password same as for the Web interface If having troubles with SFTP make sure you have SSH enabled Configuration section Services SSH Then you can connect with any client on port 22 with name and password same...

Страница 41: ...a credit card Don t bend don t scratch on this and do not expose to static electricity During cleaning of the router do not use aggressive chemicals solvents and abrasive cleaners Hereby Advantech Czech s r o company declares that the radio equipment narrated in this user s guide is in compliance with EU Directive 2014 53 EU The full text of the EU Declaration of Conformity is available at the fol...

Отзывы: