Mechanical installation
Page 18 / 61
DLT-V6210 Manual V1.00
© by DLoG GmbH
7. Mechanical installation
7.1.
Safety notice – observe before installing
WARNING
Risk of injury and damage due to improper mechanical installation.
These mounting instruction are directed to skilled personnel.
Only qualified skilled personnel may perform the mechanical installation work
on DLT-V6210.
If DLT-V6210 is incorrectly mounted, any DLoG GmbH warranty for this device will be void.
7.1.1.
Correct installation location
WARNING
Risk of injury and damage due to improper deployment location.
Observe the intended use of DLT-V6210, e.g. not in potentially explosive areas, not in life-
supporting facilities.
Ensure that the deployment location of DLT-V6210 complies with the permissible
environmental conditions.
Risk of accident on the vehicle due to limited field of view of the user.
User’s field of vision must remain free.
During installation, reserve sufficient space for DLT-V6210 and related accessories.
Make sure that the user's field of vision is not restricted in a prohibited way when mounting
peripheral devices.
Radio wave emission in the vicinity of persons.
To ensure that the limits set for exposure to radio waves are not exceeded:
Install DLT-V6210 so that persons maintain a minimum distance of 20 cm to the antenna.
NOTICE: Physical damage
Installation environment without cooling air can overheat/damage DLT-V6210.
DLT-V6210 employs a passive cooling concept whereby the waste heat generated inside the
device is emitted from the surface of the housing.
For this system to work/operate properly, sufficient fresh air circulation is required.
If there is no access to fresh cooling air, it may result in overheating and severe damage to the
device.
Never install the system in a closed environment where the cooling air is unable to dissipate
accumulated heat to the outside.
The maximum permissible ambient temperature for the entire system needs to be taken into
account for the specific application area.