Advantech B+B SmartWorx iMcV-LIM Скачать руководство пользователя страница 11

iMcV-LIM 

 

11 

 

FIBERALERT  AND FAR END FAULT 

Modules ship from the factory with troubleshooting features disabled. Refer to 

the Help file to enable/disable this feature.  

FiberAlert (FA) 

FiberAlert minimizes the problems associated with the loss of one strand of 

fiber. If a strand is unavailable, the B+B SmartWorx device at the receiver end 

notes the loss of link. The device will then stop transmitting data and the link 

signal until a signal or link pulse 
is received. The result is that the link LED on BOTH sides of the fiber 

connection will go out indicating a fault somewhere in the fiber loop. Using 

FiberAlert, a local site administrator is notified of a fault and can quickly 

determine where a cable fault is located. 

 

**WARNING** 

Enable FiberAlert at the remote side of a media conversion only. Enabling it on both sides would keep both transmitters 

disabled indefinitely. 

By default FA is disabled. When enabled if, a fault occurs on the fiber line, 

affecting data in one direction, FA stops sending signal in the opposite 

direction. FXLL will act on this lack of signal, propagating the loss of like to the 

copper port when FXLL is enabled. 

Far End Fault 

By default, FEF is disabled. When enabled, and a fault occurs on the fiber line, 

affecting data in one direction, an FEF signal will be sent in the opposite 

direction, indicating the fault. FXLL will act on this signal propagating the loss 

of link to the copper port when FXLL is enabled.  

Содержание B+B SmartWorx iMcV-LIM

Страница 1: ...iMcV LIM with LFPT ConfigControl USER MANUAL...

Страница 2: ...707 Dayton Road Ottawa IL 61350 USA Phone 1 815 433 5100 Fax 1 815 433 5105 Advantech B B SmartWorx Europe Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 ww...

Страница 3: ...9 FiberAlert and Far End Fault 11 Auto Negotiation on iMcV LIM 12 AutoCross Feature for Twisted pair Connection 13 LED Operation 14 Troubleshooting Installation 15 Specifications 16 B B SmartWorx Tech...

Страница 4: ...require items that are sold separately available from B B SmartWorx CONFIGURATION The iMcV LIM has user configurable features e g FiberAlert FA TX LinkLoss TXLL FX LinkLoss FXLL Link Fault Pass Throu...

Страница 5: ...ess of how that configuration was implemented via DIP Switch settings or SNMP Historically SNMP would override DIP Switch settings If changes are made via DIP Switch settings then hardware settings de...

Страница 6: ...uration Control modules will still be based on the last change made while those without Configuration Control will be set to their default settings NOTE If the end user has a mixture of standard iMcV...

Страница 7: ...otiation AN ON 2 Far End Fault FEF OFF 3 FX LinkLoss FXLL OFF 4 TX LinkLoss TXLL OFF 5 FiberAlert FA OFF 6 Factory Default OFF 7 Factory Default OFF 8 Factory Default OFF NOTE Best Practices When poss...

Страница 8: ...guration Control DIP Switch on S1 Feature Default Setting 1 Auto Negotiation AN ON 2 Far End Fault FEF OFF 3 FX LinkLoss FXLL OFF 4 TX LinkLoss TXLL OFF 5 FiberAlert FA OFF 6 Factory Default OFF 7 Ena...

Страница 9: ...link pulses are reaching the other end The combination of FiberAlert and LinkLoss allows this information to be obtained even when physical access to a remote device and its link integrity LED is not...

Страница 10: ...h FX and TX LinkLoss on both modules This feature allows either end of the conversion to detect a link fault occurring at the other end of the media conversion chain Regardless if there is a break in...

Страница 11: ...cal site administrator is notified of a fault and can quickly determine where a cable fault is located WARNING Enable FiberAlert at the remote side of a media conversion only Enabling it on both sides...

Страница 12: ...n there is a fault in one direction of the fiber it acts on the fiber in the opposite direction But unlike FEF FA sends no signal Because of this FA can not be enabled on both ends If it is enabled an...

Страница 13: ...ure Auto Negotiation on an iMcV LIM by adjusting the DIP Switch setting for unmanaged modules or via the management software Refer to the DIP Switch table for switch location and settings AUTOCROSS FE...

Страница 14: ...tware is disabled on the TX port FA Glows green when FiberAlert is enabled Blinks green when active FXLL Glows green when FX LinkLoss is enabled on the port Blinks when a fault occurs on the fiber por...

Страница 15: ...iMcV LIM to the twisted pair device with a twisted pair cable 2 Loop a single strand of fiber from the transmit port to the receive port of the iMcV LIM 3 Verify that both the twisted pair and the fib...

Страница 16: ...iMcV LIM 16 SPECIFICATIONS Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 25 to 70 C 13 to 158 F Humidity 5 to 95 non condensing DC Input iMcV LIM w LFPT 0 80 A 5V...

Страница 17: ...ay cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interf...

Страница 18: ...e a qualified service technician and use tools and techniques that conform to accepted industry practices FIBER OPTIC CLEANING GUIDELINES Fiber Optic transmitters and receivers are extremely susceptib...

Страница 19: ...r local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information abou...