Advantech B+B SmartWorx iMcV-Giga-MediaLinX TX/LX/SX Скачать руководство пользователя страница 8

iMcV-Giga-MediaLinX

 

 

 

SELECTIVE ADVERTISING (TX PORT) 

Selective Advertising, when used in combination with Auto Negotiation, 

advertises only the configured speed and duplex mode for the twiste- pair port. 

This allows configuration of both the twisted-pair port’s speed (10, 100 or 1000 

Mbps) and Duplex Mode (FDX or HDX). Selective Advertising (Switch 7) 

functions only with Auto Negotiation (Switch 1) enabled. 

 

Selective Advertising Configuration 

Desired 

Speed/Duplex 

Switch 2: 

Duplex 

Switch 3: Speed 

(100Mbps) 

Switch 4: Speed 

(1000Mbps) 

TX Port-1000 - FDX 

ON 

OFF 

ON

 

TX Port-100 - FDX 

ON

 

ON

 

OFF 

TX Port-100 - HDX 

OFF 

ON

 

OFF 

TX Port-10 - FDX 

ON

 

OFF 

OFF 

TX Port-10 - HDX 

OFF 

OFF 

OFF 

FORCE MODE FOR DUPLEX (TX PORT) 

The twisted pair port on the iMcV-Giga-MediaLinX TX/SFP can be set to either 

Half-Duplex or Full-Duplex operation in 10, 100, 1000Mbps (1000 Mbps is 

always FDX). Before manually setting duplex mode, disable Auto Negotiation 

by setting DIP Switch 1 to 

OFF

  The twisted pair port is configured for Full-Duplex by default, which is the 

ON

 

position on DIP Switch 2.  

  Configure the twisted pair port for Half-Duplex by setting DIP Switch 2 to the 

OFF position. 

FORCE MODE FOR SPEED (TX PORT) 

The speed on the twisted pair port (10, 100, or 1000 Mbps) can also be set to 

forced mode. Before manually setting the speed mode, disable Auto 

Negotiation by setting DIP Switch 1 to 

OFF

  Configure the twisted pair port for 10 Mbps operation by setting both DIP 

Switches 3 and 4 to the 

OFF

 position. 

  Configure the twisted pair port for 100 Mbps operation by setting DIP Switch 

3 to the 

ON

 position and DIP Switch 4 to 

OFF

  Configure the twisted pair port for 1000 Mbps operation by setting DIP 

Switch 4 to the 

ON

 position. (When 

ON

, Switch 4 overrides Switch 3). 

 

 

Содержание B+B SmartWorx iMcV-Giga-MediaLinX TX/LX/SX

Страница 1: ...iMcV Giga MediaLinX TX SFP iMcV Giga MediaLinX TX LX SX USER MANUAL...

Страница 2: ...ericas 707 Dayton Road Ottawa IL 61350 USA Phone 1 815 433 5100 Fax 1 815 433 5105 Advantech B B SmartWorx Europe Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792...

Страница 3: ...FiberAlert LFPT Far End Fault 9 Link Integrity 9 FX LinkLoss FXLL 9 TX LinkLoss TXLL 10 FiberAlert FA 10 Link Fault Pass Through LFPT 11 Far End Fault FEF 11 AutoCross Feature for Twisted Pair Connec...

Страница 4: ...enabled via a DIP Switch LFPT forces a port down state on one port when link is lost on the other port The result is the link fault passes through the device Understanding LFPT is critical to operatin...

Страница 5: ...s the iMcV module will drop for a very brief period of time 2 When introducing a management module to a chassis full of working non Configuration Control iMcV modules the iMcV modules will stop using...

Страница 6: ...iMcV modules in an unmanaged chassis use DIP Switch settings When the management module is inserted the iMcV modules use the configuration stored in the management module This will more than likely c...

Страница 7: ...ring desired settings install the module and connect appropriate cables see Installing iMcV Giga MediaLinX TX SFP section for more information DIP Switch on S1 Feature Default Setting 1 TX Auto Negoti...

Страница 8: ...ther Half Duplex or Full Duplex operation in 10 100 1000Mbps 1000 Mbps is always FDX Before manually setting duplex mode disable Auto Negotiation by setting DIP Switch 1 to OFF The twisted pair port i...

Страница 9: ...es and the copper or fiber cable coming from that device is intact The appropriate LNK link LED is lit to indicate this The B B SmartWorx media converter also sends out link pulses from its copper and...

Страница 10: ...g the fault to the copper port FIBERALERT FA FiberAlert minimizes problems associated with the loss of one strand of fiber If a strand is unavailable the B B SmartWorx device at the receiver end notes...

Страница 11: ...fiber line affecting data in one direction an FEF signal will be sent in the opposite direction indicating the fault When enabling LFPT FXLL will act on this signal propagating the loss of link to the...

Страница 12: ...X TX SFP includes the FX Negotiation feature which allows Auto Negotiation or a Force Mode on the Gigabit fiber link Enabled by default it must be enabled or disabled on both ends of the connection to...

Страница 13: ...en when link is established Blinks green when data activity occurs this is true for both LNK ACT LEDs FDX Glows amber in Full Duplex mode Off in Half Duplex mode FXLL Glows green when FX LinkLoss is e...

Страница 14: ...tware will override hardware settings Although a specific link segment either the copper or the fiber can be established if the LNK LEDS do not reflect a state of active power it is best to connect bo...

Страница 15: ...nual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the...

Страница 16: ...ou are a qualified service technician and use tools and techniques that conform to accepted industry practices FIBER OPTIC CLEANING GUIDELINES Fiber Optic transmitters and receivers are extremely susc...

Страница 17: ...nt or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information...

Отзывы: