Advantech B+B SmartWorx iMcV-Giga-MediaLinX TX/LX/SX Скачать руководство пользователя страница 6

iMcV-Giga-MediaLinX

 

 

 

5.  iMcV module DIP Switch settings can be used to make initial configuration 

settings overriding the management module’s setting. (See examples.) 

INSERTING AN IMCV MODULE 

1.  Without Configuration Control 

  DIP Switches are ignored and the iMcV module takes the 

configuration from the management module. This could be the default 

configuration or from a previously installed module. 

2.  With Configuration Control  

  If the iMcV module is different (model or DIP Switch settings) from the 

iMcV module installed in the slot previously, then the DIP Switch 

settings are used for configuration. This configuration is then copied 

up to the management module. 

  If the iMcV module is exactly the same (model and DIP Switch 

settings) to the iMcV module previously installed, the iMcV module 

will use the settings from the management module. 

 

INSERTING A MANAGEMENT MODULE 

 

Without Configuration Control 

o

  iMcV modules in an unmanaged chassis use DIP Switch settings. 

When the management module is inserted, the iMcV modules 

use the configuration stored in the management module. This will 

more than likely change the configuration of the iMcV modules -

at the very least causing a short interruption in data flowing 

through the iMcV modules.  

 

With Configuration Control 

o

  The iMcV modules copy their configuration up to the 

management module. The iMcV modules keep working with no 

configuration change and no interruption in data.  

NOTE

If the end user has a mixture of standard iMcV modules and Configuration Control 

iMcV modules, it is important to understand how SNMP and DIP Switches will impact the 

cards, depending on their capability. Standard iMcV modules cannot be upgraded to 

Configuration Control capability, so it is strongly recommended to set the DIP Switches on 

the modules and then configure them via software to match the same settings. 
 

** WARNING ** 

Installing modules without understanding the effects of LinkLoss and FiberAlert can cause 

functioning units to appear flawed or even non-functional. 

Содержание B+B SmartWorx iMcV-Giga-MediaLinX TX/LX/SX

Страница 1: ...iMcV Giga MediaLinX TX SFP iMcV Giga MediaLinX TX LX SX USER MANUAL...

Страница 2: ...ericas 707 Dayton Road Ottawa IL 61350 USA Phone 1 815 433 5100 Fax 1 815 433 5105 Advantech B B SmartWorx Europe Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792...

Страница 3: ...FiberAlert LFPT Far End Fault 9 Link Integrity 9 FX LinkLoss FXLL 9 TX LinkLoss TXLL 10 FiberAlert FA 10 Link Fault Pass Through LFPT 11 Far End Fault FEF 11 AutoCross Feature for Twisted Pair Connec...

Страница 4: ...enabled via a DIP Switch LFPT forces a port down state on one port when link is lost on the other port The result is the link fault passes through the device Understanding LFPT is critical to operatin...

Страница 5: ...s the iMcV module will drop for a very brief period of time 2 When introducing a management module to a chassis full of working non Configuration Control iMcV modules the iMcV modules will stop using...

Страница 6: ...iMcV modules in an unmanaged chassis use DIP Switch settings When the management module is inserted the iMcV modules use the configuration stored in the management module This will more than likely c...

Страница 7: ...ring desired settings install the module and connect appropriate cables see Installing iMcV Giga MediaLinX TX SFP section for more information DIP Switch on S1 Feature Default Setting 1 TX Auto Negoti...

Страница 8: ...ther Half Duplex or Full Duplex operation in 10 100 1000Mbps 1000 Mbps is always FDX Before manually setting duplex mode disable Auto Negotiation by setting DIP Switch 1 to OFF The twisted pair port i...

Страница 9: ...es and the copper or fiber cable coming from that device is intact The appropriate LNK link LED is lit to indicate this The B B SmartWorx media converter also sends out link pulses from its copper and...

Страница 10: ...g the fault to the copper port FIBERALERT FA FiberAlert minimizes problems associated with the loss of one strand of fiber If a strand is unavailable the B B SmartWorx device at the receiver end notes...

Страница 11: ...fiber line affecting data in one direction an FEF signal will be sent in the opposite direction indicating the fault When enabling LFPT FXLL will act on this signal propagating the loss of link to the...

Страница 12: ...X TX SFP includes the FX Negotiation feature which allows Auto Negotiation or a Force Mode on the Gigabit fiber link Enabled by default it must be enabled or disabled on both ends of the connection to...

Страница 13: ...en when link is established Blinks green when data activity occurs this is true for both LNK ACT LEDs FDX Glows amber in Full Duplex mode Off in Half Duplex mode FXLL Glows green when FX LinkLoss is e...

Страница 14: ...tware will override hardware settings Although a specific link segment either the copper or the fiber can be established if the LNK LEDS do not reflect a state of active power it is best to connect bo...

Страница 15: ...nual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the...

Страница 16: ...ou are a qualified service technician and use tools and techniques that conform to accepted industry practices FIBER OPTIC CLEANING GUIDELINES Fiber Optic transmitters and receivers are extremely susc...

Страница 17: ...nt or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information...

Отзывы: