Advantech B+B SmartWorx IE-iMcV-2xLIM Скачать руководство пользователя страница 4

 

IE-iMcV-2xLIM 

 

 

FCC RADIO FREQUENCY INTERFERENCE STATEMENT 

 

This equipment has been tested and found to comply with the limits for a Class B 

computing device, pursuant to Part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference when the 

equipment is operated in a commercial environment. This equipment generates, 

uses and can radiate radio frequency energy and, if not installed and used in 

accordance with the instruction manual, may cause harmful interference to radio 

communications. Operation of this equipment in a residential area is likely to 

cause harmful interference in which the user will be required to correct the 

interference at his own expense. Any changes or modifications not expressly 

approved by the manufacturer could void the user’s authority to operate the 

equipment. 
 
The use of non-shielded I/O cables may not guarantee compliance with FCC RFI 

limits. This digital apparatus does not exceed the Class B limits for radio noise 

emission from digital apparatus set out in the Radio Interference Regulation of 

the Canadian Department of Communications. 
 
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant 

les limites applicables aux appareils numériques de classe B prescrites dans le 

Règlement sur le brouillage radioélectrique publié par le ministère des 

Communications du Canada. 

 
 

ABOUT THIS MANUAL 

 

 2018 B+B SmartWorx. All rights reserved. Information in this manual is subject 

to change without notice and does not represent a commitment on the part of 

B+B SmartWorx. B+B SmartWorx assumes no responsibility for errors that may 

appear in this document. B+B SmartWorx shall not be liable for incidental or 

consequential damages resulting from the furnishing, performance or use of this 

manual.  
 
No part of this publication may be reproduced or transmitted in any form or by 

any means, electronic or mechanical, including photography, recording or any 

information storage and retrieval system without written consent.  
 
Other brands or product names used in this manual may be registered 

trademarks and the property of their respective owners. The use of trademarks or 

other designations in this publication is for reference purposes only and does not 

constitute an endorsement by the trademark holder. 
 

 

 

Содержание B+B SmartWorx IE-iMcV-2xLIM

Страница 1: ...IE iMcV 2xLIM USER MANUAL...

Страница 2: ...tWorx European Headquarters Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 www advantech bb com B B SMARTWORX TECHNICAL SUPPORT USA Canada 1 800 346 3119 Ott...

Страница 3: ...d Modules 6 LED Operation 6 FX LinkLoss TX LinkLoss Link Fault Pass Through Far End Fault 8 Link Integrity 8 FX LinkLoss FXLL 8 TX LinkLoss TXLL 8 Link Fault Pass Through LFPT 9 Far End Fault FEF 9 Au...

Страница 4: ...the Radio Interference Regulation of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num r...

Страница 5: ...manageable and can be installed into the modular SNMP manageable iMediaChassis the MediaChassis series or the MediaChassis series which are unmanaged A single DIP Switch bay offers configuration for...

Страница 6: ...manage one or more iMcV 2xLIM modules an SNMP agent must be present in the chassis To configure managed modules install the module first and then configure using the management software CONFIGURATION...

Страница 7: ...start using the Management module s settings When an iMcV module changes from DIP Switch settings to the Management module s settings the traffic across the iMcV modules will be interrupted for a ver...

Страница 8: ...FXLL Port A Off 3 TX LinkLoss TXLL Port A Off 4 Far End Fault FEF Port A Off 5 Enable TX Port Port A ON 6 Auto Negotiation AN Port B ON 7 FX LinkLoss FXLL Port B Off 8 TX LinkLoss TXLL Port B Off 9 F...

Страница 9: ...the link pulses are reaching the other end The combination of FEF and LinkLoss allows this information to be obtained even when physical access to a remote device and its link integrity LED is not ava...

Страница 10: ...nt in the opposite direction indicating the fault When enabling LFPT FXLL will act on this signal propagating the loss of link to the copper port when FXLL is enabled For more information on LinkLoss...

Страница 11: ...e Refer to the DIP Switch table for switch location and settings AUTOCROSS FEATURE FOR TWISTED PAIR CONNECTION All twisted pair ports on the IE iMcV 2xLIM TX SFP includes Auto Cross a feature that aut...

Страница 12: ...Blinks when a fault occurs on the copper port and actively disables the fiber port LNK ACT Glows green when the fiber or copper link is established Blinks green when activity is detected FEF Glows gr...

Страница 13: ...ese steps to test 1 Connect the IE iMcV 2xLIM TX SFP to the twisted pair device with a twisted pair cable 2 Loop a single strand of fiber from the Transmit port to the Receive port of the IE iMcV 2xLI...

Страница 14: ...alternate between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt ELECTROSTATIC DISCHARGE PRECAUTIONS Electrostatic discharge ESD can cause damage to any...

Страница 15: ...old waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps...

Отзывы: