ARMA-K100-CRM
30
MENU (SCREEN) PAGE #2
NOTE: These commands require that the unit be in REMOTE mode with the serial interface in
control. See screen (menu) page #1 key ‘F2’ bytes 9 & 13.
Figure 8
: Page #2 of the Communication Program
F1& F2 - N/A (not available)
F3 –
ParamS
: request for S amplifier parameters (only for 1 to 2 redundant systems).
F4 –
Auto
: puts the system in AUTO mode (this command is effective only for redundant
systems: the switching between the antenna and the dummy load will be performed
automatically).
F5 –
Manual
: puts the system in MANUAL mode (this command is effective only for redundant
systems: the switching between the antenna and the dummy load will be controlled by the
operator).
F6 –
A/Ant
: only for redundant systems, sets the switch so that the output of unit A is directed
towards the Antenna (the system should be in MANUAL mode, in order that this switching
be effective).
Copyright 1995.
F1 F2 F3
ParamS
F4
Auto
F5
Manual
F6
A/Ant
F7
B/Load
F8
Atten
F9
Thresh
F0
More
ADVANTECH - Advanced Microwave Technologies, Inc.
Address
: 0
Parameters : >00AQSWL0 A0.0O37.5
PAGE - 2 - PROTOCOL: ADV, 9600, E Rev 1.4
Alt-X to exit