Chapter 3
B
IOS Operation
Onboard Serial port 1 [3F8]
This item allows user to adjust serial port 1 address.
Serial port 1 Use IRQ [IRQ4]
This item allows the user to adjust serial port 1 IRQ.
Onboard Serial port 2 [2F3]
This item allows user to adjust serial port 2 address.
Serial port 2 Use IRQ [IRQ3]
This item allows the user to adjust serial port 2 IRQ.
SP 2 Auto Flow Control [Disable]
Auto flow control is used in RS-485 and used to control the signal transmitter
automatically.
When auto flow control is checked, the device detects the local output buffer
conditions, empty or not empty. If enable, the flow control will force signal to the
desired polarity under the empty or not empty condition.
Watch Dog Timer-Out Value Unit [Minutes]
This item allows user to select watch dog time of value unit with minutes or sec-
onds.
Watch Dog Timer-Out Value [00]
This item allows user to enabled watch dog time of value, Range is from 10 sec
~ 255 Min.
Serial port 3 [3E8]
This item allows the user to adjust serial port 3 address.
Serial 3 IRQ [IRQ5]
This item allows the user to adjust serial port 3 IRQ.
SP 3 Auto Flow Control [Disable]
Auto flow control is used in RS-485 and used to control the signal transmitter
automatically.
When auto flow control is checked, the device detects the local output buffer
conditions, empty or not empty. If enable, the flow control will force signal to the
desired polarity under the empty or not empty condition.
Serial port 4 [2E8]
This item allows the user to adjust serial port 4 address.
Serial 4 IRQ [IRQ7]
This item allows the user to adjust serial port 4 IRQ.
SP 4 Auto Flow Control [Disable]
Auto flow control is used in RS-485 and used to control the signal transmitter
automatically.
When auto flow control is checked, the device detects the local output buffer
conditions, empty or not empty. If enable, the flow control will force signal to the
desired polarity under the empty or not empty condition.
Serial port 5 [4E8]
This item allows the user to adjust serial port 5 address.
Serial 5 IRQ [IRQ10]
This item allows the user to adjust serial port 5 IRQ.
SP 5 Auto Flow Control [Disable]
Auto flow control is used in RS-485 and used to control the signal transmitter
automatically.
When auto flow control is checked, the device detects the local output buffer
conditions, empty or not empty. If enable, the flow control will force signal to the
desired polarity under the empty or not empty condition.
Содержание ARK-3390
Страница 1: ...User Manual ARK 3390 Compact Embedded Computer ...
Страница 6: ...ARK 3390 User Manual vi ...
Страница 9: ...Chapter 1 1 General Introduction This chapter gives background information on ARK 3390 series ...
Страница 15: ...Chapter 2 2 H W Installation This chapter explains the setup procedures for the ARK 3390 hardware ...
Страница 29: ...Chapter 3 3 BIOS Operation This chapter describes how to set BIOS configuration data ...
Страница 46: ...ARK 3390 User Manual 38 ...
Страница 47: ...Chapter 4 4 Full Disassembly Procedure This chapter introduce how to dis assembly the system ...