AIIS-1882 User Manual
26
A.1
Lighting Output (PWM)
A.2
Trigger for Lighting
A.3
Digital Input
Channels
4
Lighting Method
Strobe (configurable duration) or on/off mode
PWM High Time
25 ns ~ 105 ms*
PWM Low Time
25 ns ~ 105 ms*
Load Voltage
Internal power: 12VDC
External Power: 12~24VDC, follows the external power source
Load Current
Bus powered: 1A max. for each channel, total 4A max.
External power: 2A max. for each channel, total 4A max.
Isolation protection
2,500 V
DC
Trigger source
Corresponded trigger channel
* The high/low period subject to change according to actual external lighting device's
response. This is measured without external loading.
Channels
4
Input voltage
Logic 0: 2 V max.
Logic 1: 5 V min. (24 V max.)
(wet contact only)
Digital Filter
16μs~131 ms
Isolation protection
2,500 V
DC
Response time
15 μs max.
Channels
12
Input voltage
(referenced to DICOM terminal)
Logic 0: 3 V max.
Logic 1: 10 V min. (40 V max.)
Type
unipolar
Input protection voltage
70 V
Input resistance
3 kΩ typ.
Isolation protection
2,500 V
DC
Response time
100 μs max.
Digital filter
16 us ~ 131 ms software configurable
Acquisition type
Instant
Interrupt
Edge detection Rising edge, falling edge, or both edges, software
configurable per channel
Pattern match detection: By port detection, each channel can be
enabled or disabled by software independently
Frequency: 1 kHz max.
State latch: Latch port state when interrupt occurs
Содержание AIIS-1882
Страница 1: ...User Manual AIIS 1882 4 Channel PWM Lighting Controller Module for AIIS Vision System ...
Страница 8: ...AIIS 1882 User Manual viii ...
Страница 11: ...Chapter 1 1 Start Using AIIS 1882 ...
Страница 14: ...AIIS 1882 User Manual 4 ...
Страница 15: ...Chapter 2 2 Installation and Field Application ...
Страница 18: ...AIIS 1882 User Manual 8 Figure 2 3 Lighting cable assembly Figure 2 4 Module support pad sticking ...
Страница 23: ...Chapter 3 3 Function Details ...
Страница 34: ...AIIS 1882 User Manual 24 ...
Страница 35: ...Appendix A A Specifications ...