Chapter 2 Installation Guidelines
2-22 ADAM-5550KW Series User’s Manual
2.3.2 I/O modules wiring
The system uses a plug-in screw terminal block for the interface
between I/O modules and field devices. The following information
must be considered when connecting electrical devices to I/O
modules.
1. The terminal block accepts wires from 0.5 mm 2 to 2.5 mm.
2. Always use a continuous length of wire. Do not combine wires to
make them longer.
3. Use the shortest possible wire length.
4. Use wire trays for routing where possible.
5. Avoid running wires near high energy wiring.
6. Avoid running input wiring in close proximity to output wiring where
possible.
7. Avoid creating sharp bends in the wires.
2.3.3 Connection of Communication Ports
The ADAM-5550KW Series Controller has four communication ports.
These ports allow you to integrate the remote devices.
2.3.3.1 Remote I/O Wiring
Modbus/RTU Master Function via COM1/COM2/COM4 RS-485:
Figure 2-13: Remote I/O Wiring
Содержание ADAM-5550KW Series
Страница 1: ...ADAM 5550KW Series Programmable Automation Controller User s Manual...
Страница 6: ...1 System Overview...
Страница 23: ...2 Installation Guidelines...
Страница 46: ...3 Quick Start...
Страница 48: ...Chapter 3 Quick Start ADAM 5550KW Series User s Manual 3 3 Power wiring System Wiring...
Страница 65: ...Chapter 3 Quick Start 3 20 ADAM 5550KW Series User s Manual 17 Click Exit Setup 18 Click NEXT...
Страница 66: ...Chapter 3 Quick Start ADAM 5550KW Series User s Manual 3 21 19 Click NEXT 20 Click Install...
Страница 68: ...Chapter 3 Quick Start ADAM 5550KW Series User s Manual 3 23 23 Click Next 24 Click Yes...
Страница 69: ...Chapter 3 Quick Start 3 24 ADAM 5550KW Series User s Manual 25 Click Next 26 Click Next...
Страница 84: ...Chapter 3 Quick Start ADAM 5550KW Series User s Manual 3 39 27 Click OK 28 Back to graphical editor...
Страница 90: ...4 Link to Local A Studio For ADAM 5550KWAS...
Страница 127: ...5 Modbus Functions...
Страница 130: ...Chapter 5 Modbus Functions 5 4 ADAM 5550KW Series User s Manual 2 Select ADAM5000TCP_6000 item 3 Click Search button...
Страница 137: ...Chapter 5 Modbus Functions ADAM 5550KW Series User s Manual 5 11 16 Click Contact Network button 17 Double click C002...
Страница 189: ...6 AMONet On line Help...
Страница 193: ...7 Network Functions...
Страница 214: ...Chapter 7 Network Functions 7 22 ADAM 5550KW Series User s Manual 40 Click DO 0 and check the status of DO 0 is ON...
Страница 218: ...Chapter 7 Network Functions 7 26 ADAM 5550KW Series User s Manual Modify Output Range Apply Output Value...
Страница 219: ...Chapter 7 Network Functions ADAM 5550KW Series User s Manual 7 27 Set DO Value Example ADAM 5056 Template...
Страница 242: ...8 Miscellaneous Functions...
Страница 260: ...Appendix A RS 485 Network...
Страница 268: ...Appendix B Grounding Reference...
Страница 275: ...Appendix B Grounding Reference B 8 ADAM 5510KW Series User s Manual Figure B 6 wire impedance...
Страница 286: ...Appendix C Reference Documents...