1. Bolt the SSPB unit at the antenna hub by using the six mounting holes provided by the
enclosure, see
2. Ground the SSPB unit by attaching a #6 gauge copper wire to the ground terminal provided
by the unit enclosure to a properly grounded structure.
3. If it is desired to use the Relay interface, then attach the interconnecting cable fabricated per
Section 6.3.1
to the Relay connector of the SSPB unit. Connect the free end of the
interconnecting cable to the operator’s monitor and control system.
NOTE:
Whether this interface is being used or not, it is necessary to connect pin G of the
Relay connector to pin H (common) in order to enable (un-mute) the transmission
path. If pin G of this interface is not connected to pin H, the transmission path of
the unit will remain muted.
4. If it is desired to use the RS-485 interface, then connect the interconnecting cable fabricated
per
to the RS-485 port of the SSPB unit.
5. If it is desired to use the RS-232 terminal mode, then:
a. Connect the interconnecting cable fabricated per
Section 6.3.1
to the RS-232 port of the
SSPB unit.
b. Attach to the free end of the interconnecting cable a 9-pin or 25-pin D-type connector
with a pin assignment as listed in
c. Attach the cable with the 9-pin or 25-pin D-type connector to RS-232 port of the personal
computer.
TABLE 9
: SERIAL INTERFACE RS-232 CONNECTION INFORMATION
RS-232 at PC Pin
Serial Interface
RS-232 Pin
Active Condition
DB-9
DB-25
C RX
Õ
3
2
D TX
Ö
2
3
E
+5 VDC power source
-
-
F
Common
5
7
1. Connect the L-Band input source to the N-type 50
Ω
female connector Tx In input port of the
SSPB unit.
26
Содержание SSPB-Ci60
Страница 16: ...SSPB Ci60 Figure 1 Product Outline 15 ...
Страница 33: ...SSPB Ci60 Figure 4 VT RS 232 Communication Terminal Mode Display after pressing ENTER 32 ...
Страница 36: ...SSPB Ci60 Figure 5 VT RS 232 Communication List of commands after pressing h for Help 35 ...
Страница 48: ...SSPB Ci60 Figure 6 Proposed Graphic User Interface GUI based on RS 485 Protocol 47 ...