8
B.
Run Mode Explanation
The readout will display one of two modes, Run mode and Set-up mode. Run mode is
displayed only while the pump is in normal operation. The display will show the pump speed
setting.
Manual activation of the relay output and pump stroking can be activated by pressing the
ENTER key while the pump is in the run mode. This will manually activate both functions of
the unit for 3 minutes. After three minutes the unit goes back to automatic.
If the ENTER key is pressed during the 3-minute test, it will revert to automatic.
C.
Set-Up Mode Explanation
To enter Set-up mode, press MENU. Notice that a cursor appears on the screen signifying that
an adjustment can be made. To change the figure above the cursor, press the UP or DOWN
keys until the desired setting appears, then press ENTER to advance. Continue pressing
ENTER to toggle past the other displays. When all settings are made, press MENU to return
to run mode, and save settings.
D.
Password Protection
Option T allows for a built in four-digit password to prevent unauthorized changes.
Entering Setup Mode when a password has been set - Press Menu and enter the correct
four-digit password using the up and down arrow keys followed by Enter. Once the password has
been entered correctly the Setup Mode menus can be accessed. A code of 0000 disables the
password.
Set a new password
by pressing the Menu key to enter the Setup Mode. Press ENTER until
the display shows “Password: 0000” then use the up and down keys followed by the ENTER
key to set each of the four digits to the desired value.
E.
Priming the Pump
1.
Settings
Plug in pump, set stroke knob to 100%.
2.
Priming/Bleed valve
If fluid begins moving up suction line while pump is operating, no further
priming is required. If fluid is not moving, open bleed valve approximately one
turn until fluid begins to move. When suction line fills, close bleed valve.
Do not over tighten bleed valve. Damage may occur.
3.
To prime the Advantage A pump, simply press the ENTER key while the pump
is in Run mode. This allows the pump to stroke at the maximum STROKES/MIN
setting.
F.
Adjusting Feed Rate
The A pump allows for an exact number of strokes to be set and read on the front panel
LCD meter. It is adjustable from 0 to 125 strokes per minute (0 to 160 for 55 GPD).
In addition, for applications requiring very low outputs the speed can be set in strokes per
hour from 1 to 125.