Connecting the Low Voltage Ventilation Motors
The Aegis Tec includes a 10 amp, 24
VDC
motor supply. It is prewired to run multiple DC ventilation
motors. Each motor is protected by a 5 amp circuit breaker.
Replacing the 5 amp circuit breakers
with those of a larger amp rating will void the motor warranty.
Connect motors directly to the board as shown. Test motor’s direction of operation. If the motor runs
in the closing direction when it should be opening, reversing the wires at the terminals will reverse
the direction of the motor.