2
5-Minute QuickStart
Advanced Motion Controls · 3805 Calle Tecate, Camarillo, CA 93012
Phone: 805-389-1935 · Fax: 805-389-1165 · www.a-m-c.com
8
Inhibit Line Test (optional)
– Follow this step only if you installed the inhibit switch
described in the wiring section on page 6. This is to verify that the optional inhibit switch is
functioning and the drive is initially powered up in a disabled state.
1. Disconnect the motor power by unplugging the white connector on CBL-P01-10.
Unplugging this connection allows you to power up the system without the possibility
of spinning the motor.
2. Apply power to the drive. Toggle the inhibit switch and verify that you can cause the
LED color to change from Red to Green. Set the switch so the LED is Red.
3. Remove power from the drive and reconnect the white connector on CBL-P01-10.
System Power Up
1. Apply power to the drive. If an inhibit switch has been installed, enable the drive by
toggling the inhibit switch so the LED turns Green.
2. The motor should turn at a smooth controlled speed.
3. If the motor turns then the system has been hooked up correctly. Remove power
and continue to the next section. If not then go to Troubleshooting.
4. To stop the motor from turning, turn the Test/Offset switch (SW4) to the OFF
position. Then use the offset pot (Pot 4) to set the speed to zero.
Troubleshooting
LED not lit.
Verify that power has been applied to the drive.
Motor doesn’t have holding torque
Verify that the LED is Green.
LED doesn’t turn Green.
Verify all cables are connected.
If an Inhibit Switch has been installed, toggle the
Inhibit switch.
Motor doesn’t turn but has holding
torque
Turn Pot 4 (Test/Offset) in either direction. This will
change the amount of offset in the drive.
Contact Factory - If you can’t get the motor turning within a few minutes, please call and
ask for technical support! 805-389-1935. We want to get you up and running quickly!