background image

 

 

www.advancedco.com 

 

2   Operation 

2.1  Introduction 

These instructions cover the operation and use of the panels.  

2.1.1 

Front Panel Controls and Indications 

Ex-3030 

 

M

 

A

 

N

 

U

 

A

 

L

 

 

 

O

 

N

 

L

 

Y

 

A

 

U

 

T

 

O

 

 

 

+

 

 

 

M

 

A

 

N

 

U

 

A

 

L

 

D

 

I

 

S

 

A

 

B

 

L

 

E

 

D

 

F

 

A

 

U

 

L

 

T

 

T

 

I

 

M

 

E

 

R

 

 

 

H

 

E

 

L

 

D

 

A

 

B

 

O

 

R

 

T

 

E

 

D

 

R

 

E

 

L

 

E

 

A

 

S

 

E

 

I

 

M

 

M

 

I

 

N

 

E

 

N

 

T

 

R

 

E

 

L

 

E

 

A

 

S

 

E

 

D

 

E

 

X

 

T

 

I

 

N

 

G

 

U

 

I

 

S

 

H

 

A

 

N

 

T

 

Z

 

O

 

N

 

E

 

 

 

-

 

 

 

1

 

F

 

I

 

R

 

E

 

R

 

e

 

m

 

o

 

t

 

e

 

 

 

S

 

t

 

a

 

t

 

u

 

s

 

 

 

I

 

n

 

d

 

i

 

c

 

a

 

t

 

o

 

r

 

Z

 

O

 

N

 

E

 

 

 

-

 

 

 

2

 

Z

 

O

 

N

 

E

 

 

 

-

 

 

 

3

 

S

 

Y

 

S

 

T

 

E

 

M

 

 

 

F

 

A

 

U

 

L

 

T

 

M

 

O

 

D

 

E

 

S

 

U

 

P

 

P

 

L

 

Y

 

I

 

N

 

P

 

U

 

T

 

S

 

4

 

8

 

5

 

-

 

I

 

N

 

4

 

8

 

5

 

-

 

O

 

U

 

T

 

U

 

S

 

B

 

R

 

E

 

B

 

O

 

O

 

T

 

S

 

W

 

I

 

T

 

C

 

H

 

C

 

O

 

N

 

T

 

R

 

A

 

S

 

T

 

A

 

D

 

J

 

U

 

S

 

T

 

R

 

U

 

N

 

P

 

R

 

O

 

G

 

E X T I N G U I S H A N T 

R E L E A S E 

P

 

U

 

L

 

L

 

 

 

D

 

O

 

W

 

N

 

 

 

A

 

N

 

D

 

 

 

P

 

R

 

E

 

S

 

S

 

 

 

B

 

U

 

T

 

T

 

O

 

N

 

Key-Switch 
Assembly 

General Status 

LCD 

Navigation Buttons 

Manual Release 
Button 

Extinguishant Status 

 

 

Ex-3020 

The Ex-3020 has an identical arrangement to the Ex-3030 but is without the Manual Release function. 
 

2.1.1.1  Display 

The LCD along with the LED Indicators shows the operating status of the system. Examples of the information 
presented is shown below: 
 
Normal Display 

  Non-normal Display 

  Menu Display 

 

  SYSTEM NORMAL 
 
22 AUG 2007 16:39:00 

    [System status] 

 1 of  1 conditions: 
DETECTION ZONE3 
OPEN CIRCUIT 

  [Level 1 Menu] 

VIEW               

.

 

LED TEST 
EXIT 

  [Release status] 
UNAFFECTED 

 

Release Imminent  

   

Release Activated 

   

Release Complete 

  [Release status] 
RELEASE IMMINENT.. 

-15 

  RELEASE ACTIVATED 

00:00:05 Elapsed 

  RELEASE ACTIVATED 

00:00:24 Elapsed 

 
 
GAS RESET INHIBITED 

DISCHARGE COMPLETE 
(No Flow Detected) 
RESET ALLOWED 

The display shows a countdown 
timer with the amount of time 
remaining before the extinguishant 
is released. 

 

The display shows the time 
elapsed since the extinguishant 
release commenced. 

 

 

 

 

Содержание ExGo Series

Страница 1: ...www advancedco com Remote Status Indicators Installation and Commissioning The operation and functions described in this manual are available from Software Version Ex 3000 V2 05C onwards...

Страница 2: ...f 1 Relay Outputs Optional 2x rated at 1A 30VAC DC max 10mA 5V min programmable requires EXP 007 Key Switches 1x programmable Optional Fitted Optional Fitted Manual Release No No Yes Yes External Inpu...

Страница 3: ...Abort Condition 10 2 2 5 Fault Condition 10 2 2 6 Warning Condition 10 2 3 LEVEL 1 MENU FUNCTIONS 11 2 3 1 Navigating through Level 1 Menus 11 2 3 2 View 11 2 3 2 1 Faults 11 2 3 2 2 Disables 12 2 3...

Страница 4: ...se of the Ex 3000 Series Remote Status Indicating Panels The Ex 3020 is an RSI with Liquid Crystal Display and LED Indicators The Ex 3021 is an RSI with Liquid Crystal Display LED Indicators and Mode...

Страница 5: ...3030 but is without the Manual Release function 2 1 1 1 Display The LCD along with the LED Indicators shows the operating status of the system Examples of the information presented is shown below Nor...

Страница 6: ...anel has detected the folw of the extinguishant released TIMER HELD Yellow Indicates that the imminent release of extinguishant is temproraily suspended ABORTED Yellow Indicates that the imminent rele...

Страница 7: ...ions of these are programmable and the installer will have inserted a label to indicate their use Typical uses are AUTO MANUAL MANUAL ONLY Selection EXTRACT OVERRIDE Depending on the key switch mechan...

Страница 8: ...nel press the RESET button on the control panel NOTE If the programming of the panel is such that the release condition is immediately invoked on detection of a single fire alarm then the display will...

Страница 9: ...n on the control panel Section 4 12 2 Reset of the Activated Condition Release Signal NOTE In accordance with EN 12094 1 the ECD shall not permit a reset until either the RELEASED condition has been e...

Страница 10: ...UNAFFECTED NOTE The fault condition is non latching except System Fault and the indications will automatically be cleared when the fault is remedied Press the RESET key to clear a System Fault NOTE If...

Страница 11: ...u option and then press the button to select it Press the button from within a menu option to return to the previous menu The display will revert to the status mode display after 60 seconds on no acti...

Страница 12: ...e warning conditions Press the buttons to scroll through the list of warnings Press the button to return to the previous menu 2 3 2 4 Software Versions The display shows the revision of software insta...

Страница 13: ...Indicator ZONE 2 ZONE 3 SYSTEM FAULT MODE SUPPLY INPUTS 485 IN 485 OUT USB REBOOT SWITCH CONTRAST ADJUST RUN PROG COVER FIXING SCREWS The panel comprises a back box and cover chassis assembly The chas...

Страница 14: ...n the diagram below Remove the chassis before installing the enclosure retain in a safe place Ensure that there is sufficient space to allow the cover to be removed opened when the panel is finally mo...

Страница 15: ...a Safety Extra Low Voltage SELV supply Connect the 24V DC supply feed input to the SUPPLY 24V and 0V terminals on the interface card Use cables of sufficient size to ensure that the power input voltag...

Страница 16: ...t conditions see typical arrangement below EOL 6800 Maximum line impedance 50 Connect to volt free switches relay contacts only MANUAL ONLY AUTO MANUAL DISABLED FAULT TIMER HELD ABORTED RELEASE IMMINE...

Страница 17: ...description into the pocket in the fascia label Plug the connector into the respective connector on the card Key Switch assemblies are available in both trapped and non trapped versions The function...

Страница 18: ...www advancedco com 18 This page is intentionally left blank...

Страница 19: ...www advancedco com 19 USER NOTES...

Страница 20: ...ystem Emergency Abort Device Activation of Alarm Devices with Different Signals Response delay activated condition maximum 3s Response delay triggering of outputs maximum 1s EN54 2 1997 A1 Control and...

Отзывы: