Advanced AV-RMIC Скачать руководство пользователя страница 4

 

 

www.advancedco.com

4

1.2  General Installation Notes 

WARNING:

  Disconnect all sources of power (AC and 

battery) before installing/removing circuit cards or 
servicing the AV-RMIC All-Call Remote Microphone. 

USE an anti-static wrist strap whenever 
handling circuit cards. 
STORE circuit cards in static 
suppressive packaging. 

ENVIRONMENT:  

INSTALL the equipment in a clean, 

dry environment.  

The equipment meets the requirements for operation at 
32°F - 120°F (0°C - 49°C) and relative humidity of 85% 
RH. However, standby battery life is drastically reduced 
at higher temperatures. The recommended room 
temperature for installation is 60°F - 86°F (15°C - 27°C). 

WIRING:

  CHECK that the installation wire sizes are 

adequate to deliver the required load current and 
maintain compatibility with the specific device operating 
voltages. 

A secure dedicated ground connection is 
required. Although no system is immune to 
the effects of lightning strikes, a secure 
ground connection will reduce susceptibility. 
The use of overhead or outside aerial wiring is 
not recommended. 

 

1.3 FCC 

1.3.1 Emissions 

WARNING: 

 This equipment generates, uses, and can radiate radio frequency energy. If it is not installed in 

accordance with the instructions in this manual, it may cause interference to radio communications. 

This equipment has been tested and found to be in compliance with the limits for a Class A computing device 
pursuant to Subpart B of Part 15 of FCC Rules, which is designed to provide reasonable protection against such 
interference when operated in a commercial environment. Operation of this equipment in a residential area is likely 
to cause interference in which case, the user will be required to correct the interference at their expense. 
 

 

 

 

ATTENTION 

OBSERVE PRECAUTIONS 

FOR HANDLING 

ELECTROSTATIC 

SENSITIVE DEVICES 

 

Must be 

Grounded 

Содержание AV-RMIC

Страница 1: ...www advancedco com AV RMIC All Call Remote Microphone Installation Operation Manual ...

Страница 2: ...1 3 1 Emissions 4 2 INSTALLATION 5 2 1 MOUNTING 5 2 2 WIRING 6 2 2 1 AV RM PCB Remote Microphone Module 6 2 2 1 1 AV RM PCB Wiring to AV RMIC Microphone 7 2 2 1 2 AV RM PCB Wiring to AV RMI AV AMP 80 7 2 2 1 3 AV RM PCB Status LEDs 8 2 2 2 AV RMI Remote Microphone Interface Module 9 2 2 2 1 AV RMI Enclosure Mounting 11 3 SPECIFICATIONS 13 ...

Страница 3: ...nclosure The AV RMIC consists of AV MIC REM Lockable enclosure with removable inner and outer doors and microphone AV RM PCB Remote microphone module which interfaces to AV RMI and AV AMP 80 amplifier see figure 2 The AV RM PCB supervises the AV RMIC microphone for open circuit short circuit and disconnection conditions The audio output of the AV RM PCB is supervised for open and short circuit con...

Страница 4: ...ages A secure dedicated ground connection is required Although no system is immune to the effects of lightning strikes a secure ground connection will reduce susceptibility The use of overhead or outside aerial wiring is not recommended 1 3 FCC 1 3 1 Emissions WARNING This equipment generates uses and can radiate radio frequency energy If it is not installed in accordance with the instructions in ...

Страница 5: ...g The AV RMIC all call remote microphone enclosure is designed for either surface or semi flush mounting 1 2 flange around enclosure When mounting remove both the outer and inner doors of the AV RMIC enclosure Surface Mounting The AV RMIC enclosure back box has three 3 mounting holes located on the back wall of the back box see opposite The top center mounting hole is keyed for ease of mounting Pl...

Страница 6: ... gets wired to a single AV VBM AV VB AX CTL x V or command center AV AMP 80 amplifier via a supplied AV RMI remote microphone interface module 2 2 1 AV RM PCB Remote Microphone Module The AV RM PCB is pre mounted to the inner door of the AV RMIC enclosure see figure 2 Figure 2 AV RM PCB Pre Mounted to AV RMIC Inner Door ...

Страница 7: ...ee figure 3 2 2 1 2 AV RM PCB Wiring to AV RMI AV AMP 80 The remaining terminals of the AV RM PCB get wired to the AV RMI remote microphone interface module and AV AMP 80 amplifier located at the AV VBM AV VB AX CTL x V or command center see figure 4 Note For correct wiring type refer to Section 3 AV RMIC Specifications Wiring Recommended Figure 3 AV RM PCB Prewired Microphone Connections ...

Страница 8: ...is supplied to the AV RMIC Supply OK Trouble Illuminates when a trouble condition occurs on the AV RM PCB Additional in depth diagnostic LEDs Supply Trouble Illuminates on a low voltage condition Audio Short Circuit Audio output short circuit Audio Open Circuit Audio output open circuit Microphone Disconnected Disconnection of Microphone Microphone Switch Trouble Microphone held open Figure 4 AV R...

Страница 9: ...ding supervision and connection to the AV RMIC all call remote microphone when the AV RMIC microphone is keyed the MIC KEY output of the AV RMI module activates input three 3 of the AV AMP 80 amplifier initiating amplifier boost mode for all call microphone broadcasting see figure 6 and 7 Note If the single AV AMP 80 amplifier also incorporates a local microphone the AV AMP 80 s microphone will ha...

Страница 10: ...OUBLE SUPPLY OK TROUBLE OUT OUT I N IN A MP 1 OUT OUT IN I N AM P2 24V GND 24V GND P OWE R B A B A RS 485 AM P 1 A A B B A MP 2 A A B B INP UTS I N1 GND I N2 GND I N3 GND TROUB LE COM NO NC TX HB AMP1 AMP2 40V USB To AV ZS Audio Zone Splitter Module if installed Trouble Relay 24V AC DC 1 0A PF 1 POWER LIMITED FAIL SAFE Open Contact Energized when Normal 100K EOL end of line resistor Figure 6 AV RM...

Страница 11: ... fire alarm control panel 2 2 2 1 AV RMI Enclosure Mounting AV VBM or AV VB Mounting TX HB AMP1 AMP2 40V USB 24V IN GND IN GND OUT 24V OUT MIC MON T R B L MON MIC KEY R E L N O RE L COM COM AL L CA LL P OWER S UPPLY AV RMI Module Figure 8 AV RMI Mounting within an AV VBM or AV VB Enclosure Figure 7 AV RMI Module ...

Страница 12: ...ter December 2013 For retrofit installations pre December 2013 back boxes an AV RMI RP retrofit plate is available AV RMI Module Mounted on back box lower inner wall Figure 9 AV RMI Mounting within an AX CTL x V or Command Center Enclosure 24V IN GND IN GND OUT 24V OUT MIC MON TR BL MON MIC KEY R EL N O REL COM COM AL L CALL P OWER S UPPLY ...

Страница 13: ...RM PCB Remote Microphone Module AV RM PCB Remote Microphone Module AV RMI Remote Microphone Interface Module AV RMI RP AV RMI Retrofit Plate AV RMIC Specifications Operating Voltage 17 to 28 VDC Operating Current Quiescent Microphone Active 070 Amp 085 Amp Wiring recommended 24 VDC Supply Microphone Audio End of Line EOL Microphone Trouble Monitoring All Wiring is Supervised and Power Limited Twis...

Страница 14: ...advancedco com 14 Doc Number 682 046 AFS Revision 1 Advanced Fire Systems Inc 100 South Street Hopkinton Massachusetts 01748 Tel 508 435 9995 Fax 508 435 9990 Email usa advancedco com Web www advancedco com ...

Отзывы: