17
6. Accidental Release Measures
Ventilate area of leak or spill. Remove all sources of ignition. Wear appropriate personal protective
equipment as specified in Section 8. Isolate hazard area. Keep unnecessary and unprotected personnel from
entering. Contain and recover liquid when possible. Use non-sparking tools and equipment. Collect liquid in
an appropriate container or absorb with an inert material (e. g., vermiculite, dry sand, earth), and place in a
chemical waste container. Do not use combustible materials, such as saw dust. Do not flush to sewer! US
Regulations (CERCLA) require reporting spills and releases to soil, water and air in excess of reportable
quantities. The toll free number for the US Coast Guard National Response Center is (800) 424-8802.
J. T. Baker SOLUSORB® solvent adsorbent is recommended for spills of this product.
7. Handling and Storage
Protect against physical damage. Store in a cool, dry well-ventilated location, away from any area where the
fire hazard may be acute. Outside or detached storage is preferred. Separate from incompatibles.
Containers should be bonded and grounded for transfers to avoid static sparks. Storage and use areas
should be No Smoking areas. Use non-sparking type tools and equipment, including explosion proof
ventilation. Containers of this material may be hazardous when empty since they retain product residues
(vapors, liquid); observe all warnings and precautions listed for the product.
8. Exposure Controls/Personal Protection
Airborne Exposure Limits:
- OSHA Permissible Exposure Limit (PEL):
1000 ppm (TWA) for ethyl alcohol
400 ppm (TWA) for isopropyl alcohol
200 ppm (TWA) for methyl alcohol
- ACGIH Threshold Limit Value (TLV):
1000 ppm (TWA), A4 - not classifiable as a human carcinogen for ethyl alcohol
200 ppm (TWA), 400 ppm (STEL), A4 - not classifiable as a human carcinogen for isopropyl alcohol
200 ppm (TWA), 250 ppm (STEL) skin, for methyl alcohol
Ventilation System:
A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne
Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the
contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH
document,
Industrial Ventilation, A Manual of Recommended Practices
, most recent edition, for details.
Personal Respirators (NIOSH Approved):
If the exposure limit is exceeded, wear a supplied air, full-facepiece respirator, airlined hood, or full-facepiece
self-contained breathing apparatus.
Skin Protection:
Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to
prevent skin contact.
Eye Protection:
Use chemical safety goggles and/or a full face shield where splashing is possible. Maintain eye wash
fountain and quick-drench facilities in work area.
9. Physical and Chemical Properties
Appearance:
Clear, colorless liquid.
Odor:
Mild pleasant whiskey-like odor.
Solubility:
Miscible in water.
Density:
0.79 @ 20C/4C
pH: