Symptom:
Probable Cause:
Suggested Remedy:
Unit does not light
No power to unit
Check power supply & cord
Line voltage is <90 VAC
Use @ rated voltage
Power supply failure
Contact Authorized Distributor
Driver failure
Contact Authorized Distributor
One color won’t light
Damaged driver
Contact Authorized Distributor
LED board short
Contact Authorized Distributor
Low performance
Dirty Lens
Clean lens w/ soft dry cloth
Damaged lens
Contact Authorized Distributor
Damaged sub-optic board
Contact Authorized Distributor
No DMX response
Bad cable connection
Check cables
DMX driver malfunction
Contact Authorized Distributor
Address issues
Check for proper DMX address
9.0 Maintenance of Luminaire
8.0 Troubleshooting
Prior to any maintenance or service of the unit, always disconnect power cord and allow unit to
cool for at least five (5) minutes.
Periodic Cleaning:
Clean the LiveLED at least once every 6 months. Dust exterior with a soft cloth. Make certain that
lenses are free of obstructions and debris.
Fuse Replacement
In the event that the fuses need to be replaced, use only 250 volt 5 amp AC type of fuse. Turn the
power OFF; remove the power cord from the power outlet. Locate the fuse holder on the rear of
the fixture. Remove and replace the fuses if needed. Plug in the power cord and the unit is ready
for continued operation.