Table 5‑6. Data logger parameters
Parameter Number
Parameter Definition
Description
P450.00
Data logger on or off
Switches the data logger
on and off:
• 0: Off
• 1: On (data is
recorded regularly)
P451.00
Data logger time interval
Contains the time interval
(60, 300, 600 seconds)
frequency at which the
data logger saves data.
P452.00-39
Parameter number data
logger
Contains a list of all
parameter numbers that
are to be recorded. This
only works in conjunction
with the indices (P453.x).
Parameter numbers that do
not exist are ignored.
P453.00-39
Indices data logger
Contains a list of all
indices for the parameter
numbers that are to be
recorded. This only works
in conjunction with the
parameter numbers
(P452.x). Parameter
numbers that do not exist
are ignored.
To Configure the Data Logger Settings
1. Press the
F1
button to display the main menu.
2. Press the ▼ button until
Configuration
is highlighted, and then press the enter
button.
3. Press the ▼ button until
Extended
is highlighted, and then press the enter
button.
4. Press the ▼ button until
Numerical List
is highlighted, and then press the
enter button.
5. To navigate to a specific parameter, use the ▲ and ▼ buttons to highlight the
parameter, and then press the enter button.
a. Use the ◄ and ► buttons to highlight specific numbers.
b. Use the ▲ and ▼ buttons to change the number value.
Advanced Energy® AE 3TL Inverters
570-1003552-05A
Operating
5‑17
Содержание AE 3TL 1000 Series
Страница 2: ......
Страница 12: ...Advanced Energy xii 570 1003552 05A List of Tables...
Страница 14: ...Advanced Energy xiv 570 1003552 05A List of Figures...
Страница 26: ...Advanced Energy 1 12 Safety and Product Compliance Guidelines 570 1003552 05A...
Страница 64: ...Advanced Energy 4 28 Installing 570 1003552 05A...
Страница 86: ...Advanced Energy 6 4 Operating the Arc Fault Detection Unit 570 1003552 05A...
Страница 92: ...Advanced Energy 7 6 Data Monitoring and Controls 570 1003552 05A...
Страница 110: ...Advanced Energy 9 14 Troubleshooting and Solar Energy Technical Support 570 1003552 05A...
Страница 116: ...Advanced Energy A 6 Specifications 570 1003552 05A...
Страница 118: ...Figure 11 2 AE 3TL mechanical diagram Advanced Energy B 2 System and Mechanical Diagrams 570 1003552 05A...
Страница 120: ...Advanced Energy B 4 System and Mechanical Diagrams 570 1003552 05A...