GENERAL INFORMATION  

 
DESCRIPTION

 

 
The Advanced Detection Systems ProScan Max II™ is a general purpose, digital metal detector suitable for the 
detection of ferrous and nonferrous metals in all types of food products, chemicals, plastics, or other products 
where metal  can have an unwanted consequence. In addition  to providing excellent product quality control, it 
provides  protection  for  machinery  by  letting  you  know  there  is  metal  in  your  product  before  it  causes  costly 
damage.  
 
The  metal  detector  search  head  is  manufactured  to  suit  specific  product  requirements,  thereby  ensuring 
maximum sensitivity. It is essentially a single oscillator-driven loop with twin receiving coils. All three coils are 
mounted in a welded stainless steel enclosure and completely filled with epoxy for protection against water and 
vibration.  
 
When  correctly  balanced,  the  signals  in  the  two  receiving  coils  cancel  (i.e.  they  are  equal  in  magnitude  and 
opposite in  sign). As metal  passes between the oscillator and a receiving  coil, the current  induced in  that coil 
changes. This causes an imbalance, which is amplified and detected in the electronic control unit.  
 
The  ProScan  Max  II™  metal  detector  uses  surface  mount  technology  and  integrated  circuits.    Automatic 
balance  compensation  eliminates  the  need  for  manual  balancing.  Internal  computer  timing  controls  reject  and 
alarm devices, and can also be used to stop the conveyor motor upon detection of metal.  
 
The ProScan Max II™ metal detector is a digital detector with a digital interface. All controls and adjustments 
are  made  with  a  touchscreen  that  also  contains  pushbutton  shortcut  keys.    Product  settings  can  be  stored  for 
quick line changeovers. Other features include multi-password protection and detect counter.  
 
 
 

SPECIFICATIONS

   

 

AC Supply

 – 115 volts, 60 Hz, less than 50 VA  

 
 

Stability

 - Suitable stability is maintained under the following conditions:  

32-115

o

 F (0-45

o

 C)  

0-90% humidity  
+ 10% voltage variation  
 

Sensitivity

 - Sensitivity varies with detector type, size, and product being inspected.  

As a result, it is quoted separately for each application.  
 
 

 
 
 
 
 

Содержание ProScan Max II

Страница 1: ...Metal Detector INSTALLATION GUIDE AND OWNER S MANUAL Advanced Detection Systems 4740 W Electric Avenue Milwaukee WI 53219 414 672 0553 Phone 414 672 5354 Fax www adsdetection com P N 807732 Rev 4 6 2...

Страница 2: ...tal Detector Auto Learn Procedure 12 Product Selection 12 Tips for Successful Auto Learn 16 Additional Items for Product Set Up 17 Naming the Product 17 Product Settings 18 Phase Setting 18 Sensitivit...

Страница 3: ...site in sign As metal passes between the oscillator and a receiving coil the current induced in that coil changes This causes an imbalance which is amplified and detected in the electronic control uni...

Страница 4: ...ct pipes with emulsions or gravity system product chutes should pass through the center of the detector opening without touching the walls of the aperture The product being inspected should pass throu...

Страница 5: ...l strip housed inside of the separate power box A terminal connections chart is located on page 5 and on the inside of the power box cover Main power is applied to the metal detector via Terminals L I...

Страница 6: ...s other than those supplying the metal detector Caution should be used when working on machinery as components may stop and start automatically without warning POWER INPUT OUTPUT BOARD RLY 5 15 VDC IN...

Страница 7: ...y closed contact for relay 2 PULSE and RESET inputs OPTO INPUT Input for photo eye RLY2 NO Normally open contact for relay 2 PULSE INPUT Input for external timing pulses 5 VDC OUT Locally available 5...

Страница 8: ...y time if you want the contaminated product to stop at a particular spot on the conveyor If you want the conveyor to stop immediately set the delay time to zero The conveyor may be restarted by pressi...

Страница 9: ...8...

Страница 10: ...9...

Страница 11: ...s discussion we will use the Windows File File method of navigating around the menu As an example if we needed to go to the Reject Options screen we would say MENU LEVEL 3 PASSWORD REJECT OPTIONS The...

Страница 12: ...all aspects of the product such as sensitivity reject control and timing product learn product naming etc LEVEL 3 Allows the operator LEVEL 2 functions as well as the ability to change system settings...

Страница 13: ...LL BE DESCRIBED BELOW It is a good idea to first read the following section Tips for Successful Auto Learn before beginning the auto learn process PRODUCT SELECTION Product selection is available on a...

Страница 14: ...to perform the learn function Logging in on level 2 produces the following screen Now press the PRODUCT SET UP button to go to the learn menu The following screen will appear Now press the LEARN RELE...

Страница 15: ...there is a continuous line uninterrupted line of products This learn method allows a hands off learn A continuous pipeline of liquid or a uninterrupted line of candy bars would be appropriate for thi...

Страница 16: ...en metal comes through the detector it makes a large enough signal to go above the detect point and the detector sees metal If the product is very consistent the learn margin can be set close to the p...

Страница 17: ...roducts will give uncertain phase values For all practical purposes partially frozen meat products should not be used for auto learning 5 Make sure the sample product is uncontaminated by metal If by...

Страница 18: ...MENU The following screen will appear The default name for each product is Product 1 Product 2 etc Press the Product Name to make the keyboard appear Enter the name you have chosen for this product up...

Страница 19: ...tely by the learn process and generally should not have to be adjusted by the user SENSITIVITY 1 SENSITIVITY 2 The metal detector has two channels of sensitivity During the learning process the metal...

Страница 20: ...anually configure the sensitivity of your detector using the Product Monitor it is first necessary to understand the correlation between the sensitivity settings and the product monitor values The det...

Страница 21: ...oduct tracking is a method of averaging the signal coming from the product so that as the signal changes gradually during the day the allowed signal will gradually change also The product tracking men...

Страница 22: ...conds Reject operate time Sets the time that the reject device stays activated It can be adjusted in tenths of a second from 0 30 seconds On detection of metal the reject device light and or alarm wil...

Страница 23: ...bring up the RELAY CONTACT SETUP screen After changing the configuration of the relays you MUST press the SAVE SETTINGS button to make the change permanent The metal detector is usually mounted on a c...

Страница 24: ...o provide compensation for two metal detection situations The metal is at the leading edge of the package In this case the rejection device may operate slightly sooner than when the package actually a...

Страница 25: ...metal has been detected since the counter was last reset Reset the counter during product changeover for more accurate product run information To reset the counter go to MENU LEVEL 3 PASSWORD REPORTS...

Страница 26: ...al samples When enabled this feature reminds the user that performance validation is due Access to the performance validation feature is through the Reports hard key on the left When pressed the follo...

Страница 27: ...listed on the data logger along with a time and date stamp upon successful completion of the ferrous test Enter the desired values for each metal type Enter Validation Set Up and the following screen...

Страница 28: ...in From the Performance Validation Menu screen select Validation Ferrous The following screen will appear Test the product with the ferrous test wand If a detection occurs press Test Passed If it did...

Страница 29: ...owered from sources other than those supplying the metal detector Caution should be used when working on machinery as components may stop and start automatically without warning Most faults found with...

Страница 30: ...xcessive vibration CONSTANT FALSE TRIPS Check to make sure that the product being inspected has not changed in any way If a product changes in moisture temperature or mass it will change the product s...

Страница 31: ...ded These variables are adjusted using the Reject Delay Time and Reject Operate Time in the metal detector menu By adjusting the sweep arm speed on either the retreat or attack rate it may be necessar...

Страница 32: ...regarding sweep arm adjustments HANDLING MOVING AND TRANSPORTING THE UNIT When moving the detector be sure the unit is powered off Exercise caution to avoid tipping the unit When lifting the unit wit...