Enter  the  desired  shift  start  time,  test  interval  and  end  time.    Then,  turn  the  validation  reminder  on.    The 
performance validation reminder is now active.  When the current time matches the test interval the following 
performance reminder screen will appear: 
 

 

 
 
Selecting ‘Cancel’ simply returns the system to the main screen.  Selecting ‘Begin’ navigates the user back to 
the ‘Performance Validation Menu’ screen shown previously.  Please note: the user will be prompted for the 
level  3  access  password  when  selecting  ‘Begin’.    From  the  ‘Performance  Validation  Menu’  screen  select 
‘Validation Ferrous’.  The following screen will appear:   
 
 

 

 
Test  the  product  with  the  ferrous  test  wand.    If  a  detection  occurs  press  ‘Test  Passed’.    If  it  did  not  or  an 
unwanted detection occurs press ‘Test Failed’.  The data logger will record the ferrous test wand size entered 
previously and the date and time of the detection only if a detection occurs and the user presses ‘Test Passed’.  
Otherwise  no  recording  to  the  data  logger  is  made  noting  the  performance  validation  test.    When  the  test  is 
complete the user will be sent back to the ‘Performance Validation Menu’.  Select the ‘Validation Non-Ferrous’ 
Button and repeat the process.  Repeat entire process for stainless. 
 
 
 
 

Содержание ProScan Max II

Страница 1: ...Metal Detector INSTALLATION GUIDE AND OWNER S MANUAL Advanced Detection Systems 4740 W Electric Avenue Milwaukee WI 53219 414 672 0553 Phone 414 672 5354 Fax www adsdetection com P N 807732 Rev 4 6 2...

Страница 2: ...tal Detector Auto Learn Procedure 12 Product Selection 12 Tips for Successful Auto Learn 16 Additional Items for Product Set Up 17 Naming the Product 17 Product Settings 18 Phase Setting 18 Sensitivit...

Страница 3: ...site in sign As metal passes between the oscillator and a receiving coil the current induced in that coil changes This causes an imbalance which is amplified and detected in the electronic control uni...

Страница 4: ...ct pipes with emulsions or gravity system product chutes should pass through the center of the detector opening without touching the walls of the aperture The product being inspected should pass throu...

Страница 5: ...l strip housed inside of the separate power box A terminal connections chart is located on page 5 and on the inside of the power box cover Main power is applied to the metal detector via Terminals L I...

Страница 6: ...s other than those supplying the metal detector Caution should be used when working on machinery as components may stop and start automatically without warning POWER INPUT OUTPUT BOARD RLY 5 15 VDC IN...

Страница 7: ...y closed contact for relay 2 PULSE and RESET inputs OPTO INPUT Input for photo eye RLY2 NO Normally open contact for relay 2 PULSE INPUT Input for external timing pulses 5 VDC OUT Locally available 5...

Страница 8: ...y time if you want the contaminated product to stop at a particular spot on the conveyor If you want the conveyor to stop immediately set the delay time to zero The conveyor may be restarted by pressi...

Страница 9: ...8...

Страница 10: ...9...

Страница 11: ...s discussion we will use the Windows File File method of navigating around the menu As an example if we needed to go to the Reject Options screen we would say MENU LEVEL 3 PASSWORD REJECT OPTIONS The...

Страница 12: ...all aspects of the product such as sensitivity reject control and timing product learn product naming etc LEVEL 3 Allows the operator LEVEL 2 functions as well as the ability to change system settings...

Страница 13: ...LL BE DESCRIBED BELOW It is a good idea to first read the following section Tips for Successful Auto Learn before beginning the auto learn process PRODUCT SELECTION Product selection is available on a...

Страница 14: ...to perform the learn function Logging in on level 2 produces the following screen Now press the PRODUCT SET UP button to go to the learn menu The following screen will appear Now press the LEARN RELE...

Страница 15: ...there is a continuous line uninterrupted line of products This learn method allows a hands off learn A continuous pipeline of liquid or a uninterrupted line of candy bars would be appropriate for thi...

Страница 16: ...en metal comes through the detector it makes a large enough signal to go above the detect point and the detector sees metal If the product is very consistent the learn margin can be set close to the p...

Страница 17: ...roducts will give uncertain phase values For all practical purposes partially frozen meat products should not be used for auto learning 5 Make sure the sample product is uncontaminated by metal If by...

Страница 18: ...MENU The following screen will appear The default name for each product is Product 1 Product 2 etc Press the Product Name to make the keyboard appear Enter the name you have chosen for this product up...

Страница 19: ...tely by the learn process and generally should not have to be adjusted by the user SENSITIVITY 1 SENSITIVITY 2 The metal detector has two channels of sensitivity During the learning process the metal...

Страница 20: ...anually configure the sensitivity of your detector using the Product Monitor it is first necessary to understand the correlation between the sensitivity settings and the product monitor values The det...

Страница 21: ...oduct tracking is a method of averaging the signal coming from the product so that as the signal changes gradually during the day the allowed signal will gradually change also The product tracking men...

Страница 22: ...conds Reject operate time Sets the time that the reject device stays activated It can be adjusted in tenths of a second from 0 30 seconds On detection of metal the reject device light and or alarm wil...

Страница 23: ...bring up the RELAY CONTACT SETUP screen After changing the configuration of the relays you MUST press the SAVE SETTINGS button to make the change permanent The metal detector is usually mounted on a c...

Страница 24: ...o provide compensation for two metal detection situations The metal is at the leading edge of the package In this case the rejection device may operate slightly sooner than when the package actually a...

Страница 25: ...metal has been detected since the counter was last reset Reset the counter during product changeover for more accurate product run information To reset the counter go to MENU LEVEL 3 PASSWORD REPORTS...

Страница 26: ...al samples When enabled this feature reminds the user that performance validation is due Access to the performance validation feature is through the Reports hard key on the left When pressed the follo...

Страница 27: ...listed on the data logger along with a time and date stamp upon successful completion of the ferrous test Enter the desired values for each metal type Enter Validation Set Up and the following screen...

Страница 28: ...in From the Performance Validation Menu screen select Validation Ferrous The following screen will appear Test the product with the ferrous test wand If a detection occurs press Test Passed If it did...

Страница 29: ...owered from sources other than those supplying the metal detector Caution should be used when working on machinery as components may stop and start automatically without warning Most faults found with...

Страница 30: ...xcessive vibration CONSTANT FALSE TRIPS Check to make sure that the product being inspected has not changed in any way If a product changes in moisture temperature or mass it will change the product s...

Страница 31: ...ded These variables are adjusted using the Reject Delay Time and Reject Operate Time in the metal detector menu By adjusting the sweep arm speed on either the retreat or attack rate it may be necessar...

Страница 32: ...regarding sweep arm adjustments HANDLING MOVING AND TRANSPORTING THE UNIT When moving the detector be sure the unit is powered off Exercise caution to avoid tipping the unit When lifting the unit wit...