6.2 Positioning
The control unit must be fi rmly fi xed to the wall or to another stable and robust support. A
support plate is provided to facilitate this operation.
The fl oor height of the unit must be at least 18 cm in order to allow the removal of the fi lter and
the emptying of the bucket.
2
Trace the drilling points using the plate supplied as drilling
template
Do the drilling
1
Screw the screws into the dowels and
check that the plate is well anchored to
the wall.
3
Hook the suction unit to the anchor plate by lifting
it, placing it against the wall and lowering it until it
engages in the fi xing plate.
4
3- in single-pipe systems, the maximum length allowed for the various sections of pipe, despite
being limited by the components chosen for your system, is more generous, but even in these ca-
ses it is necessary to evaluate in advance the characteristics and technical data provided for each
component installed.
4- paths with many curves or with very close curves should always be avoided.
5- the minimum radius of the curves must be equal to or greater than 0.5 meters.
6- sections of pipes that include both positive and negative siphons must be avoided.
7- the sections of horizontal pipes must be kept perfectly leveled.
8- vertical pipe sections longer than 3.5 meters must always be avoided and at the bases of these
the minimum radius of the bends must be equal to or greater than 1 meter
9- the sections of piping where fuel passes must be well fi xed at least every 1.5 meters.
10- the pipe sections may be built-in or installed under fl ooring, but only for very short linear traces
and only by inserting them into an additional casing pipe of properly larger diameter.
It is recommended to use only pipes, fi ttings and accessories present in our catalog, as they have
been designed, tested and built specifi cally for these systems.
Before installation and start-up of the system, it is essential to carefully read the instructions sup-
plied with the various components and in case of doubts it is advisable to contact specialized
personnel.
The realization of the systems and the installation of the components must always meet the
safety standards corresponding to the type of rooms in which they are positioned.