FORM NO. 56380890
-
7
MAINTENANCE
1) Use only approved chemicals at the recommended mix ratios. All chemicals should be added through the feed system and NOT
added directly to the water in the solution tank to prevent possible damage to the pump, seals, or other components.
2) For optimum performance,
fl
ush the Chemical Feed lines after every job by replacing the chemical containers with containers of
clear water and spraying through the gun until the
fl
uid stream is clear. See the Maintenance Schedule, below.
3) The pump seals and/or valves in the high pressure pumps may need to be replaced after about 1000 hours of use, if the pump
begins to loose performance or to leak. The pressure regulator valve may need to be when a drop in the spraying pressure at the
tool is apparent.
4) If the 4”, clear lid is removed from the top of the base (solution tank), you will need to apply a silicone sealant to the threads when
you reinstall the lid to seal for vacuum leaks.
MAINTENANCE SCHEDULE
ITEM
DAILY
WEEKLY
QUARTELY
YEARLY
Flush chemical lines
X
Check/clean vac inlet
fi
lter
X
Clean solution
fi
lter
X
Check vacuum motor airways
X
Check pump for leaks
X
Check vacuum motor brushes*
X
* Have Advance check the carbon brushes once a year or after about 500 hours of operation.
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
MODEL
56380772
56381594
VACUUM MOTOR:
2 stage, 8 amp
2 stage, 8 amp
WATER LIFT:
97”
97”
AIR FLOW:
100 CFM
100 CFM
TANK CONSTRUCTION:
Rotationally molded polyethylene
Rotationally molded polyethylene
SOLUTION TANK CAPACITY:
20 gallon
20 gallon
RECOVERY TANK CAPACITY:
12 gallon
12 gallon
APPLICATION FLOW:
200 psi
400 psi
VAC & SOLUTION HOSE LENGTH:
15 feet
15 feet
POWER CORD:
25 feet
25 feet
HEIGHT:
38.5 inches
38.5 inches
WIDTH:
21.25 inches
21.25 inches
LENGTH:
34 inches
34 inches
WEIGHT
85 LBS
85 LBS
revised 10/10