background image

 6 - 

FORM NO. 56380890

OPERATION

1)  Insert the appropriate metering tips into the chemical feed lines (see illustration, page 5).
2)  Fill the holding tank with warm water (not exceeding 120 °F). 

Do not

 add any chemical to the tank.

3)  Prepare the area for cleaning by emptying waste receptacles, clearing debris, removing paper products, blowing out vents, and 

sweeping 

fl

 oors.  

4)  Connect the 25 ft power cord to the pig-tail on the rear of the machine. Test the GFCI on the power cord before each use. Plug the 

GFCI protected power cord into an outlet. 

5) 

PRIME THE PUMP

: Attach the priming hose to the outlet quick disconnect and place the open end of the hose into the recovery 

tank. Turn on the pump and let it run until the pump is completely primed (no visible air in the water stream). Turn the pump off. 

 

NOTE:

 prime the machine before you place the chemical feed tubes into chemical containers.

6)  Disconnect the priming hose and attach the solution hose to the quick disconnect.
7)  Attach the spray gun to the other end of the solution line.
8)  Place chemicals in the molded-in chemical bottle containers on the rear of the machine.  Insert one of the feed lines into one of the 

chemical containers. Secure the line by screwing on the cap. The chemical will feed from which ever container the selector valve on 
the switch plate is turned towards and when the gun is used in the low pressure setting. Use chemicals with a pH of between 4 and 
12. Never add chemicals to the clean water tank.

9)  Set the spray gun to low pressure by sliding the pressure selector forward (low pressure = forward; high pressure = back).
10)  Turn on the pump switch (push button) and spray through the gun for a few seconds to 

fi

 ll the line with solution.

11)  Apply the chemical to the walls and 

fi

 xtures from the bottom up. Spray the 

fl

 oor last as you work your way out of the room.

12)  Allow the chemical to work for the proper amount of dwell time, according to the chemical manufacturer’s directions. Agitate heavily 

soiled areas with a scrub brush.

13)  Turn off the chemical injector valve by turning the selector to the down position. 
14)  Set the spray gun to high pressure and rinse the area from the top down.
15)  Connect the vacuum hose, attach the squeegee, and turn on the vacuum (rocker switch).
16)  Squeegee off the mirrors, pick up the liquid off the 

fl

 oor with the 

fl

 oor tool. If you have the optional blow dry hose, use it to dry the 

fi

 xtures.

17)  Drain the recovered water into a utility sink or toilet.  NOTE: Keep the top of the drain hose higher than the water level in the tank to 

avoid uncontrolled discharge of water when you open the cap on the hose.

 CAUTION

To avoid vacuum motor damage, always use a defoamer any time foam is present.
Before you turn on the vacuum always make sure the 

fi

 lter screen on the ball 

fl

 oat is clean and that the ball can travel freely.

  RE-PRIMING THE PUMP

If the pump looses prime between jobs, follow the instructions to PRIME THE PUMP, above. If that doesn’t get water 

fl

 owing, put the 

priming hose into the vacuum inlet hose barb and cover the rest of the space around the priming hose with your hand. Turn on the 
vacuum (with the pump also running) and let the suction of the vacuum assist in getting water into the pump.

Содержание ALL CLEANER

Страница 1: ...INSTRUCTIONS FOR USE AND PARTS LIST MODELS 56380772 56381594 2 10 revised 1 11 Document Number 56380890 ALL CLEANER ALL CLEANER XP...

Страница 2: ...all parts of your body away from the openings and moving parts Do not pick up anything that is burning or smoking or any health endangering dusts Turn off all controls before unplugging Always use ch...

Страница 3: ...r than 120 F 54 C 120VAC GROUNDING INSTRUCTIONS This appliance must be grounded If it should electrically malfunction grounding provides a path of least resistance for electric current to reduce the r...

Страница 4: ...level in the tank to avoid sudden uncontrolled flow of waste water when you remove the cap then lower the hose slowly to control the rate of discharge Quick Disconnect 7 Point of attachment for the Sp...

Страница 5: ...2 switches between the two chemical containers When the selector is pointed straight down the valve is off and neither chemical is selected When the selector is pointed directly towards one or the oth...

Страница 6: ...ure by sliding the pressure selector forward low pressure forward high pressure back 10 Turn on the pump switch push button and spray through the gun for a few seconds to fill the line with solution 1...

Страница 7: ...the top of the base solution tank you will need to apply a silicone sealant to the threads when you reinstall the lid to seal for vacuum leaks MAINTENANCE SCHEDULE ITEM DAILY WEEKLY QUARTELY YEARLY Fl...

Страница 8: ...8 FORM NO 56380890 O I O 1 2 4 5 6 10 16 11 12 13 15 21 14 24 22 23 25 17 9 20 3 26 19 8 7 23B 3B 18 16 15 17 26 400 PSI 200 PSI revised 10 10...

Страница 9: ...1 Tie Wire 8 W Mounting Hole 1 Chain 8 W D Couplings Both E 1 Tie Wire 8 W Mounting Hole 1 Cap Raw With Tether 13 56380843 1 Fasteners kit 2 Hinge Pin 1 4 X 2 25 S S 1 Clip Handle Black Vinyl Coated 1...

Страница 10: ...hose 25 ft 9 56380865 Bucket 10 qt Tool Kit standard complete 56380846 200PSI 56381618 400PSI 1 2 7 6 8 1 56108017 Squeegee hand held 12 2 56380853 Handle 12 for hand squeegee 3 56380804 Pressure Line...

Страница 11: ...CE 4 VAC ALL CLEANER P N 408 ALL CLEANER XP AND TFC 400 P N 408 APC 328 400PSI P N 407A ALL CLEANER XP AND TFC 400 P N 2060 120V 0 0 0 0 0 0 0 0 4 OF HEAT SHRINK P N 1649 GRN BLK WHT WHT 14 AWG 14 5 B...

Страница 12: ...14600 21st Avenue North Plymouth MN 55447 3408 www advance us com Phone 800 989 2235 Fax 800 989 6566 2011 Nilfisk Advance Inc A Nilfisk Advance Brand...