INSTRUCTIONS FOR USE
ENGLISH
Micromatic™ M17B
909 5853 000(3)2008-11
19
SOLUTION FILTER CLEANING
Empty the solution tank (32) as shown in the relevant paragraph.
1.
Drive the machine on a level
fl
oor.
2.
Make sure that the switches (65 and 66) are turned to “0”.
3.
Remove the transparent cover (A, Fig. 8) and the
fi
lter strainer (B); clean and reinstall them on the support (C).
4.
NOTE
The
fi
lter strainer (B) must be correctly positioned on the housing (D) of the support (C).
C
B
A
B
D
Figure 8
S310232A
MACHINE SPEED ADJUSTMENT
NOTE
The machine speed varies according to the type of
fl
oor to be cleaned and the choice of using the brush or the pad.
The machine speed can be adjusted according to the following procedure.
Remove the recovery tank as shown in the Use chapter.
1.
Adjust the machine speed with the screw (53) according to the following procedure:
2.
Loosen the screw (57), on the right side of the machine, by turning it counter-clockwise.
•
Turn the adjusting screw (53) counter-clockwise to increase the machine speed.
•
Turn the adjusting screw (53) clockwise to decrease the machine speed.
•
After adjusting, tighten the screw (57).
•
Install the recovery tank as shown in the Use chapter.
3.
With the machine ready to operate, perform hands-on tests of the machine and, if other adjustments are necessary, repeat
4.
steps 1 to 4.