background image

 

 

Adtron Corporation 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev. 003 

PN: 610200094 

I

I

3

3

5

5

M

M

B

B

 

 

-

-

 

 

3

3

.

.

5

5

M

M

i

i

r

r

r

r

o

o

r

r

e

e

d

d

 

 

H

H

a

a

r

r

d

d

 

 

D

D

i

i

s

s

k

k

O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

s

s

 

 

M

M

a

a

n

n

u

u

a

a

l

l

March 2006

 

Содержание 610200094

Страница 1: ...Adtron Corporation Rev 003 PN 610200094 I I3 35 5M MB B 3 3 5 5 M Mi ir rr ro or re ed d H Ha ar rd d D Di is sk k O Op pe er ra at ti io on ns s M Ma an nu ua al l March 2006...

Страница 2: ...herein This document may contain or reference information or products protected by copyrights or patents and does not convey any license under the patent rights of Adtron Corporation nor the rights o...

Страница 3: ...Button Functions 8 Advanced Operations 8 Managing Faults 8 Bank Hard Faults 9 Bank Soft Faults 9 Turning the Buzzer Off 10 Changing Media 10 Resetting Mirroring Indicators 12 Rebuilding a bank 13 Reb...

Страница 4: ...ignificantly reduces the probability of a data storage failure causing an overall system failure Figure 1 I35MB I35MB Features Adtron ActiveRAID technology featuring RAID 1 mirrored disk drives indepe...

Страница 5: ...does not discharge into the I35MB I35MB Jumper Settings The master slave and remote LED jumper is located on the front of the I35MB between the IDE and power connectors This jumper is used to set mas...

Страница 6: ...e master device default With a jumper placed on pins 1 and 2 the I35MB is the slave device When a jumper is placed on pins 1 and 3 the cable select configuration is utilized Refer to the above Figure...

Страница 7: ...connector Figure 5 I35MB interface I35MB Installation Introduction The I35MB is a 3 5 inch hard disk drive and mounts into a standard 3 5 inch hard disk drive bay The drive may be mounted from the si...

Страница 8: ...f the chassis provides a front removable panel the buzzer reset and fault LEDs can be viewed by removing the plastic panel on the chassis 5 Using an 80 conductor cable 40 pin connector connect the I35...

Страница 9: ...itioning and Formatting To the operating system the I35MB looks like a single disk drive All RAID 1 functions occurring in the I35MB are transparent to the operating system Use the operating system ut...

Страница 10: ...he LED states Activity LED D10 Description Green No access Power is on Orange flashing Reads or writes occurring on hard disk Orange flashing in a set pattern Indicates an issue with the I35MB Bank LE...

Страница 11: ...conds LED flashes fast 4 sec No Operation 15 20 seconds LED solid on Reserved 20 seconds LED off No Operation Table 2 Mirror Control Button operations Functions marked reserved are for Adtron factory...

Страница 12: ...eplaced See Turning the Buzzer Off on page 10 for more information Adtron recommends regularly backing up data and should a fault occur scheduling a replacement and rebuild as soon as possible If eith...

Страница 13: ...e is required To turn the buzzer off 1 If possible pop the removable plastic panel off the drive bay in which the I35MB is installed If the I35MB does not have front access through a drive bay continu...

Страница 14: ...g the flex cables to bow in a loop Refer to Figure 10 Carefully disconnect the flex cable from the faulted disk drive Detaching the drives from the flex cable in a forceful manner will damage the flex...

Страница 15: ...ront LEDs and buttons must be available to do the rebuild 15 After securing the I35MB a rebuild must be performed Go to Rebuilding a Bank on page 13 Resetting Mirroring Indicators The procedure below...

Страница 16: ...e the rebuild process may be impacted slowed Rebuilding a Bank Off line Only the power connection is required to do the rebuild if you want to have a rebuild complete before bringing the drive on line...

Страница 17: ...data from the Bank 0 20GB drive to the new drive in Bank 1 The I35MB remains a 20GB mirrored device Bank 0 media is replaced with a 60GB unit The rebuild copies the operational 20GB from Bank 1 The I...

Страница 18: ...ed and screwed into place Firmly tighten both screws but do not over tighten 2 Repeat assembly sequence from step 1 with the right rail 3 Align the drive assembly retention screw 4 with the left rail...

Страница 19: ...specifically apply to the I35MB are summarized below and a more detailed description appears in Table 3 Contact Adtron for more S M A R T details Attribute 121 Hard Fault Bank 0 Attribute identifies t...

Страница 20: ...en this LU indicated READY in the host interface milliseconds 0 113 0x71 Rebuild remaining 0 16 bit value 0x0000 no rebuild activity 0xFFFF rebuild starting else percent ffff 0 remaining 0 120 0x78 Ha...

Страница 21: ...start of hard reset to the end of hard or soft reset If a soft reset is received the value could be quite large and misleading 120a This attribute only available in mirrored units 120b 1st 2nd 3rd ref...

Страница 22: ...on line GREEN flashing 1 sec See Note 1 GREEN Becoming on line OFF OFF ORANGE Button released processing Drive removed OFF ORANGE GREEN Replace drive and rebuild Drive reinserted OFF ORANGE GREEN Must...

Страница 23: ...on line GREEN flashing 1 sec See Note 1 ORANGE Becoming on line OFF OFF ORANGE Button released processing Drive removed OFF ORANGE ORANGE Replace drive and rebuild Drive reinserted OFF ORANGE ORANGE M...

Страница 24: ...Adtron I35MB Operations Manual Rev 003 PN 610200094 21 I35MB Dimension Drawings 25 3 997 6 32 x 3 8 150 MAX DEPTH 3X 101 6 4 000 5 750 146 1 Figure 11 I35MB...

Страница 25: ...t Items numbers correspond with Figure 11 under the section of this document titled Using the I35MB Rail Kit Item Number Quantity Description 1 Four 4 Rail Retention Screw M3 x 5 2 One 1 Rail Left 3 O...

Страница 26: ...54 Fax 45 4557 0753 Email nordic adtron com Germany Sales Tel 49 821 589 9914 Fax 49 821 589 7190 Email deutsche adtron com United States Technical Support Europe Technical Support Tel 1 602 735 0300...

Страница 27: ...610200094 24 Revision Control Rev Author Date Sections Description 001 JMH Apr 2005 All Original 002 JMH Aug 2005 Connector 8 pin change to the connector 003 JMH Mar 2006 SMART Rail Kit Adding SMART...

Отзывы: