Connecting the Alarm Contacts

1. Connect the NO (Normally Open) alarm contact of the MAIN TRACER BBP (labeled 1 below) to the MN alarm contact in the IN alarm 

block of the TRACER MPS (labeled 2 below). The TRACER BBP provides two sets of alarm contacts; for normal configuration, use 
the NO located in the MAJ (Major Alarm) block.

2. Connect the COM (Common) alarm contact of the MAIN TRACER BBP (labeled 3 below) to the COM alarm contact in the IN alarm 

block of the TRACER MPS (labeled 4 below). Repeat this step for the STANDBY TRACER BBP. 

3. Connect the NO alarm contact of the STANDBY TRACER BBP to the SB alarm contact in the IN alarm block of the TRACER MPS 

(labeled 5 below).

4. (OPTIONAL) Connect the TRACER MPS alarm contacts (NO, COM, NC) in the OUT alarm block (labeled 6 below) to your external 

alarm monitoring system. Failure to follow this step will not affect TRACER MPS redundancy operation.

Only the TRACER 2603 BBP provides the optional MIN (Minor Alarm) terminal block. Connecting the MIN alarm contacts allows the 
TRACER MPS to perform a system switch when a minor alarm condition occurs. Please refer to the TRACER 2603 User Manual 
(ADTRAN P/N 61280003L1-1) for a detailed listing of major and minor alarms.

MANAGEMENT

T

R

A

C

E

R

MAIN

STANDBY

OUT

NO  COM  NC

MN  COM  SB

IN

ALARMS

DC POWER

RF

ANTENNA

TO DTE RS-232

MONITOR

T1B

T1A

MAIN

TRACER

STANDBY

TRACER

MONITOR

POWER

MODULE

USE COPPER

CONDUCTORS ONLY

OUT

IN

IN

OUT

B

A

B

A

MAIN

STAND

BY

T1B

T1A

MANAGEMENT

T

R

A

C

E

R

MAIN

STANDBY

OUT

NO  COM  NC

MN  COM  SB

IN

ALARMS

DC POWER

RF

ANTENNA

TO DTE RS-232

MONITOR

T1B

T1A

MAIN

TRACER

STANDBY

TRACER

MONITOR

POWER

MODULE

USE COPPER

CONDUCTORS ONLY

OUT

IN

IN

OUT

B

A

B

A

MAIN

STAND

BY

T1B

T1A

4

2

6

5

.

All alarm contact connections in the steps below should be made using standard 18 AWG insulated conductors. Insert the conductor in 
the terminal block then use a flat-head screwdriver to secure the connection.

NO Alarm Contact

COM Alarm Contact

MN Alarm Contact

Connect to
External Alarm
System

COM Alarm Contact

SB Alarm Contact

3

1

Содержание TRACER Protection Switch

Страница 1: ...acts between the TRACER BBP or 4103 4203 and the TRACER MPS also needed for connecting the MPS to an external alarm monitoring system Antenna mounting hardware and feedline cable 21 to 63 VDC power so...

Страница 2: ...below each BBP T R A C E R MAIN STANDBY OUT NO COM NC MN COM SB IN ALARMS DC POWER RF ANTENNA TO DTE RS 232 MONITOR T1B T1A MAIN TRACER STANDBY TRACER MONITOR POWER MODULE USE COPPER CONDUCTORS ONLY M...

Страница 3: ...OR T1B T1A MAIN TRACER STANDBY TRACER MONITOR POWER MODULE USE COPPER CONDUCTORS ONLY OUT IN IN OUT B A B A MAIN STAND BY MANAGEMENT T1A T1B STANDBY UNIT VT100 Connection MAIN UNIT VT100 Connection 1...

Страница 4: ...tatus parameters 5 Activates the menu system for the STANDBY TRACER unit This provides access to all configuration and status parameters 6 Configures the TRACER MPS for modem or terminal access When c...

Страница 5: ...s labeled 3 and 4 below 2 Repeat Step 1 to connect the T1A and T1B interfaces of the STANDBY TRACER BBP to the STANDBY T1A and T1B interfaces RJ 45 of the TRACER MPS labeled 5 below MAIN UNIT T1B Inte...

Страница 6: ...labeled 1 below to the MAIN RF interface SMA con nector of the TRACER MPS labeled 2 below using a male N Type to male SMA cable 2 Connect the IF connector on the MAIN TRACER BBP labeled 4 below to th...

Страница 7: ...3 below T R A C E R MAIN STANDBY OUT NO COM NC MN COM SB IN ALARMS DC POWER RF ANTENNA TO DTE RS 232 MONITOR T1B T1A MAIN TRACER STANDBY TRACER MONITOR POWER MODULE USE COPPER CONDUCTORS ONLY OUT IN...

Страница 8: ...ovides the optional MIN Minor Alarm terminal block Connecting the MIN alarm contacts allows the TRACER MPS to perform a system switch when a minor alarm condition occurs Please refer to the TRACER 260...

Страница 9: ...e applied voltage in Volts As an example at 48 Volts the TRACER MPS would draw approximately 0 417 Amps peak 20 Watts 48 Volts 9 Pinouts MAIN STANDBY T1A T1B INTERFACES RJ 45 Pin Name Description 1 R...

Отзывы: