Wall Mounting the Total Access 912/916/924 BBU
Figure 6
shows the BBU mounting dimensions for the Total Access 912/916/924.
Figure 6. Wall Mounting the 1175044L1 BBU
For a wallmount installation, the BBU installs on heavy plywood (3/4-inch minimum) using four
#10 x 3/4-inch pan-head wood screws. Install the BBU as follows:
Instructions for Wall Mounting the 1175044L1 BBU
Step
Action
1
Determine the preferred unit layout to ensure cable plugs reach their designated sockets.
2
Ensuring a plumb measurement, mark where the pilot holes are to be drilled according to the
dimensions given in the documentation included with your shipment.
3
Drill all four pilot holes using a size 1/16-inch drill bit.
4
Screw in the top two pan-head screws that fit the keyhole openings. Let the head of each
screw protrude 1/16 inch from the plywood to engage the keyhole slot.
Do not let the weight of the BBU rest on the two keyhole screws. Maintain support
until the lower two screws are fully inserted.
5
With an assistant, lift the BBU and position to engage the screw heads. Allow the unit to slide
down until the slot end rests against the screws.
6
Insert the two lower screws through the tabs and tighten securely.
7
Use cable ties as appropriate. The battery connection from the BBU should be directly
connected to the
BATT
port on the rear of the chassis.
Содержание Total Access 908
Страница 10: ...List of Figures Total Access 900 Series Hardware Installation Guide 10 Copyright 2010 ADTRAN Inc 61210916L1 34G...
Страница 12: ...List of Tables Total Access 900 Series Hardware Installation Guide 12 Copyright 2010 ADTRAN Inc 61210916L1 34G...
Страница 34: ...Appendix A Total Access 900 Series Hardware Installation Guide 34 Copyright 2010 ADTRAN Inc 61210916L1 34G...
Страница 36: ...Index Total Access 900 Series Hardware Installation Guide 36 Copyright 2010 ADTRAN Inc 61210916L1 34G...