1.

INTRODUCTION

The Total Access 900 Series products are Internet Protocol (IP) business gateways designed for 
cost-effective deployment of up to 1.536 Mbps of Session Initiation Protocol (SIP), Point-to-Point Protocol 
(PPP), or Frame Relay voice and data services. The Total Access 900 Series combines voice and data 
services into a single platform for IP telephony service providers, such as competitive local exchange 
carriers (CLECs), incumbent local exchange carrieres (ILECs), and Internet service providers (ISPs). 

Total Access 900 Series products are built on the ADTRAN Operating System (AOS) platform and include 
the AOS built-in IP router and firewall features. The units include a T1 network interface (

NET T1 0/1

) or 

an asymmetric digital subscriber line (ADSL) network interface (

NET ADSL 0/1

) (Total Access 904 and 

Total Access 908 only), a DSX-1 interface (

DSX-1 T1 0/2

), a 

VOICE 

interface (up to 24 foreign exchange 

station (FXS) ports or 16 FXS plus 8 foreign exchange office (FXO) ports), a 10/100Base-T interface, and 

CRAFT

 port (management interface). An optional battery backup is also available for the Total Access 

900 Series. The last two digits of the product name indicate the number of onboard FXS ports. The Total 
Access 904 contains 4 FXS ports, the Total Access 908 contains 8 FXS ports, the Total Access 912 
contains 12 FXS ports, the Total Access 916 contains 16 FXS ports, and the Total Access 924 contains 24 
FXS ports or 16 FXS ports plus 8 FXO ports with the octal FXO daughterboard. The units can provision, 
test, and provide status for any of the voice and data interfaces. All connections are made using the rear 
panel.

In common packet-based applications, the wide area network (WAN) (

NET T1 0/1

) connects to the ISP or 

carrier’s network and transmits packetized voice and data over a SIP trunk. The customer’s voice is 
presented as time division multiplexing (TDM) to the FXS ports or DSX-1 interface, and the data is routed 
out the local area network (LAN) (

ETH 0/1

).

Features and Specifications

The Total Access 900 Series products have the following features:

Supports up to 24 FXS ports with octal FXS daughterboard

Supports up to 16 FXS ports and 8 FXO ports with octal FXO daughterboard (Total Access 924 only)

Supports a single DS1 interface and a single DSX-1 interface

Supports a single ADSL network interface (Total Access 904/908 ADSL only)

Supports primary rate interface (PRI) or robbed bit signaling (RBS) on the DSX-1 interface

Supports a single auto medium dependent interface/medium dependent interface crossover 
(MDI/MDIX) 10/100Base-T Ethernet ports (RJ-48C)

Stateful inspection firewall

Quality of service/network address translation/Dynamic Host Configuration Protocol (QoS/NAT/
DHCP) client, server, and relay

Supports SIP trunks 

Supports Frame Relay, PPP, or serial asynchronous transfer mode (ATM)

Supports three-way conferencing

Supports caller ID, message waiting, and stutter dial tone

Fax and analog modem compatible (V.90)

Supports local station-to-station calls

Up to 24 channels of G.711 (

μ

-law)

Up to 24 channels of G.729

Содержание Total Access 908

Страница 1: ...Total Access 900 Series Hardware Installation Guide Total Access 904 Total Access 908 Total Access 912 Total Access 916 Total Access 924 61210916L1 34G April 2010...

Страница 2: ...reof as a result of issue of this publication Software Licensing Agreement Each ADTRAN product contains a single license for ADTRAN supplied software Pursuant to the Licensing Agreement you may a use...

Страница 3: ...L1 34G Copyright 2010 ADTRAN Inc 3 Conventions Notes provide additional useful information Cautions signify information that could prevent service interruption or damage to the equipment Warnings prov...

Страница 4: ...fire They may explode Check with local codes for special disposal instructions 5 The socket outlet shall be installed near the equipment and shall be easily accessible If any of the following conditi...

Страница 5: ...o user serviceable parts 6 This equipment is designed to connect to the telephone network or premises wiring using an FCC compatible modular jack which is compliant with Part 68 and requirements adopt...

Страница 6: ...nt of the certification registration number signifies that the Industry Canada technical specifications were met Notice The REN for this terminal equipment is supplied in the documentation or on the p...

Страница 7: ...ools Required 20 Mounting Options 21 Wall Mounting Total Access 900 Series 21 Rack Mounting Total Access 900 Series 22 Grounding Instructions 23 Grounding for AC Power 24 Supplying Power to the Unit 2...

Страница 8: ...Total Access 900 Series Hardware Installation Guide Table of Contents 8 Copyright 2010 ADTRAN Inc 61210916L1 34G...

Страница 9: ...Total Access 900 Series Front Panel Layouts 15 Figure 2 Total Access 900 Series Rear Panel Layouts 17 Figure 3 Voice Connector Pin Assignments 19 Figure 4 Wall Mounting the Unit 22 Figure 5 Wall Mount...

Страница 10: ...List of Figures Total Access 900 Series Hardware Installation Guide 10 Copyright 2010 ADTRAN Inc 61210916L1 34G...

Страница 11: ...al Access 900 Series LEDs 16 Table 2 BBU Specifications 29 Table A 1 VOICE Connector Pinouts 31 Table A 2 NET T1 0 1 Pinouts 32 Table A 3 NET ADSL 0 1 Pinouts 32 Table A 4 DSX 1 T1 0 2 Pinouts 32 Tabl...

Страница 12: ...List of Tables Total Access 900 Series Hardware Installation Guide 12 Copyright 2010 ADTRAN Inc 61210916L1 34G...

Страница 13: ...s 924 contains 24 FXS ports or 16 FXS ports plus 8 FXO ports with the octal FXO daughterboard The units can provision test and provide status for any of the voice and data interfaces All connections a...

Страница 14: ...to the quick start documents provided on your AOS Documentation CD or online at http kb adtran com Unpack and Inspect the System Each Total Access 900 Series unit is shipped in its own cardboard shipp...

Страница 15: ...ont panels the Total Access 904 contains 4 FXS ports the Total Access 908 contains 8 FXS ports the Total Access 912 contains 12 FXS ports the Total Access 916 contains 16 FXS ports and the Total Acces...

Страница 16: ...ff All ports are inactive or administratively shut down Green solid At least one port is off hook Green flashing At least one port is ringing Amber At least one port is in test Red Fault condition DAT...

Страница 17: ...m part number is P N 1175044L1 or L2 The connection port is labeled BATT Refer to the documentation available for your specific battery backup unit for more information on this connection or refer to...

Страница 18: ...e is a DS1 RJ 48C pin connection See Table A 2 on page 32 for the T1 network interface pinouts The NET ADSL 0 1 interface is an ADSL RJ 48 pin connection See Table A 2 on page 32 for the ADSL network...

Страница 19: ...912 only uses circuits 1 through 12 The Total Access 916 only uses circuits 1 through 16 The Total Access 924 uses all circuits 1 through 24 and the FXO interfaces are on circuits 17 through 24 26 1...

Страница 20: ...on your CD All documents related to the Total Access 900 Series are also available online at http kb adtran com Tools Required The following customer provided tools are required for the hardware inst...

Страница 21: ...e or run it through walls ceilings floors or openings in the building structure The socket outlet must be installed near the equipment and must be easily accessible Instructions for Wall Mounting Tota...

Страница 22: ...Total Access 904 and Total Access 908 are not rack mountable ADTRAN recommends 1U 1 75 inches of separation above and below the Total Access 900 Series unit This spacing allows the unit to dissipate h...

Страница 23: ...the electrical service equipment ground If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient temperature Ther...

Страница 24: ...ground at the service equipment Supplying Power to the Unit As shipped each Total Access 900 Series product is set to factory default conditions After installing the unit the Total Access 900 Series...

Страница 25: ...ug provides quick and easy installation All mounting hardware included Total Access 912 916 924 BBU P N 1175044L1 L2 The BBU connects to the Total Access 912 916 924 through a 6 foot charge discharge...

Страница 26: ...using walls Removing batteries or disconnecting wires compromises correct reassembly and should not be attempted BBU Safety and EMC Notices This device complies with Part 15 of the FCC rules Operation...

Страница 27: ...ensure cable plugs reach their designated sockets 2 Ensuring a plumb measurement mark where the pilot holes are to be drilled according to the dimensions given in the documentation included with your...

Страница 28: ...ere the pilot holes are to be drilled according to the dimensions given in the documentation included with your shipment 3 Drill all four pilot holes using a size 1 16 inch drill bit 4 Screw in the to...

Страница 29: ...ing of the batteries Federal and state laws prohibit the improper disposal of all lead acid batteries The customer is responsible for the handling of their batteries from the day of purchase through t...

Страница 30: ...Battery Backup Unit Total Access 900 Series Hardware Installation Guide 30 Copyright 2010 ADTRAN Inc 61210916L1 34G...

Страница 31: ...p 9 34 Circuit 9 FXS 0 9 Ring Tip 10 35 Circuit 10 FXS 0 10 Ring Tip 11 36 Circuit 11 FXS 0 11 Ring Tip 12 37 Circuit 12 FXS 0 12 Ring Tip 13 38 Circuit 13 FXS 0 13 Ring Tip 14 39 Circuit 14 FXS 0 14...

Страница 32: ...Receive data from the network Tip 1 3 Unused 4 R Transmit data toward the network Ring 5 T Transmit data toward the network Tip 6 8 Unused Pin Name Description 1 3 Unused 4 T ADSL Tip 5 R ADSL Ring 6...

Страница 33: ...tion 1 DCD Data Carrier Detect output 2 RD Receive Data output 3 TD Transmitted Data input 4 DTR Data Terminal Ready input 5 GND Ground connected to unit chassis 6 DSR Data Set Ready output 7 RTS Requ...

Страница 34: ...Appendix A Total Access 900 Series Hardware Installation Guide 34 Copyright 2010 ADTRAN Inc 61210916L1 34G...

Страница 35: ...14 installation general 20 rackmount 23 wallmount 21 27 28 installing 20 L LEDs front panel 16 rear panel 17 M maintenance of battery backup unit 29 mounting options 21 rack 22 wall 21 N NET ADSL 0 1...

Страница 36: ...Index Total Access 900 Series Hardware Installation Guide 36 Copyright 2010 ADTRAN Inc 61210916L1 34G...

Отзывы: