The Total Access

®

 480 Outdoor Multi-Dwelling Unit ONT (MDU) is designed 

to accommodate up to four Total Access series Optical Network Terminations 
(ONTs). The following ONT modules can be installed in the MDU:

Total Access 352 2 POTS/2 Ethernet SFU ONT 

Total Access 352H 2nd Generation SFU ONT 

Total Access 362 2 POTS/2Ethernet 1 RF SFU ONT

Total Access 374 4 POTS/4 GigE MDU ONT

Figure 1

 illustrates the MDU with the Outer Door removed.

 

Figure 1.  MDU Housing

Included Components

The following components are included with the MDU:

Parts Bag

P1 Connector (1 ea, P/N 3202007CN01-E) 

Outer Ground Lug (1 ea, P/N 3198001PN21-E)

ONT Connector (4 ea, P/N 3202007CN00-E, Total Access 374 only)

Cable Assy (4 ea, P/N 3125P135-E)

#10-32 x 3/8 Machine Screws (6 ea, P/N 327611028-E)

#10-16 x 3/8 Plastite Screw (8 ea, P/N 327600205-E)

Lock Washer, External Tooth (2 ea, P/N 3284018-E)

There are two, 1-inch, and four, 2-inch knockouts on the bottom of the MDU 
that can be used as access points for electrical and optical fibers. 

The 1” holes are for ¾” conduit fittings, or ¾” NPT liquid tight fittings.

The 2” holes are for 1 ½” Conduit fittings, 1 ½” NPT liquid tight fittings or 
PG 36 Liquid Tight fittings.

ONT Support Brackets

F1

DSL/POTS 25-48

F2

F3

F4

Outer
Ground 
Lug

Fiber
Tray

Power
Distribution
Block

P1

P2   P3   P4  P5

Ground Connection
Support Bracket

Ground Connection
Fiber Tray 

N

ote: The Ground Wires 

between the Support
Brackets and Fiber Tray
are factory-installed, and
are longer than illustrated.
These wires provide
continued grounding to 
prevent disruption of power
if the Support Brackets are
uninstalled while the ONT is
powered.

Power Entry
Port

Fiber Entry
Port

Ground Wires
(4 ea)

Total Access 480 

 Outdoor Multi-Dwelling Unit ONT

I

NSTALLATION

After unpacking the MDU, inspect it for damage. If damage is noted, file a 
claim with the carrier and then contact ADTRAN. For more information, refer 
to the warranty.
Installation consists of the following steps:

Install the MDU

Install the ONT in the MDU

Connect power and services to the MDU

Optional Installations:

OptiTap Installation

Splitter Installation

Installation Guidelines

WARNING

!

Read all warnings and cautions before installing or servicing the MDU.

Use extreme care when attaching the ground connectors to the utility
(earth) ground rod. If the ground is interrupted or disturbed in any way, an
unsafe condition will exist. Refer to the National Electrical Code (NEC) and
state and local codes for details on grounding requirements.

CAUTION

!

The Network Interface Device (NID) mounting screws and Telco access
screw are part of the ground path. Insure these screws are tightened
securely using the appropriate tool.

Use a UL Listed ITE power supply with LPS output rated minimum 12
VDC, 5 Amps suitable for the intended location.

MDU Installation Overview

To install the MDU, complete the following steps:

1. Mount the MDU
2. Ground the MDU
3. Connect Power to the MDU

Required Tools and Supplies

Standard technician tools and those listed below are required for installing the 
MDU:

Carpenter’s level

3/32 inch screw driver for connecting MDU power

5/32 inch pin-in hex bit

RJ-45/RJ-11 crimper

A telephony/data communication test set

PON power meter with wavelength filtering

Fiberscope or videoscope

Inch-pound torque wrench

Two 5/16 or 3/8 x 2-inch minimum, lag bolts and appropriate anchors (as 
necessary) for mounting the MDU

Assorted tie wraps for securing cabling and wiring

Fiber cleaning tools

Product P/N: 61287733F1

Issue Date: January 2016

Document P/N: 61287733F1-22E

Documentation for ADTRAN Carrier Networks products is available for 

viewing and download directly from the ADTRAN Support Community 

website. 
Go to: 

https://supportforums.adtran.com/welcome

Registration is required.
ADTRAN offers training courses on our products, including customized 

training and courses taught at our facilities or at customer sites.
For inquiries, go to:

 http://adtran.com/training

The following documents provide additional information for this product:

Total Access 300 Series Single Family Unit ONT Installation and Maintenance Guide
Total Access 374 4-POTS,4-GigE MDU ONT Installation and Maintenance Guide 
Total Access 5000 Series Fiber to the Premises Deployment Guide 
Total Access 5000/5006 Engineering Guide 