TOTAL ACCESS 234 SHDSL NTU
P/N 1200708L1
For more detailed documentation, visit us online at
www.adtran.com
Quick Start Guide
Quick Start Guide, 61200708L1-13B, January 2005
Technical Support 1-888-4ADTRAN or +1-256-963-8716
Copyright © 2005 ADTRAN, All Rights Reserved
C
ONNECT
THE
C
ONSOLE
I
NTERFACE
Before connecting to the Total Access 234 console interface, you will need the following items: VT100
terminal or PC (with VT100 terminal emulation software) and a straight through serial cable with a DB-9
(male) connector on one end and the appropriate interface for your terminal (or PC) on the other.
1. Connect the DB-9 (male) connector of your serial cable to the console port on the rear
panel of the unit.
2. Connect the loose end of the serial cable to the VT100 terminal or PC (with terminal
emulation software).
3. Open a VT100 terminal session to the Total Access 234 using the following settings:
9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press <Enter> to activate the
ADTRAN Command Line Interface (CLI).
C
ONFIGURE
G
ATEWAY
IP A
DDRESSES
/S
UBNET
M
ASK
Configure the Gateway IP addresses and subnet mask by following
these steps. If you are not sure what IP address to assign, please
contact your network administrator.
1. Enter
enable
to activate the Enable command security mode.
2. When prompted, enter the enable password (if configured).
3. Enter
config terminal
to activate the Global configuration mode.
4. Enter
bre lan-gw
10.26.12.12
wan-gw
100.26.12.12 mask
255.255.255.0*
to assign LAN and WAN Gateway IP addresses
and subnet mask.
*Note:
Underlined text represents example entries only. Modify
them to match your configuration.
5. Enter
exit
to return to the Enable configuration mode.
6. Enter
copy running-config startup-config
to save the running
configuration to the unit’s non-volatile memory (NVRAM).
NET
ETH
F
EATURES
•
One integrated EIA-232 configuration port (DCE)
•
One integrated 10/100BaseT Ethernet port
•
2-Wire/4-Wire SHDSL interface
•
WAN Protocol: ATM
•
Command Line Interface (CLI)
•
Management - EOC/CLI using Virtual Terminal
•
Front panel LEDs
•
Wall mounting available with additional parts
S
PECIFICATIONS
DC Input Power
12 VDC nominal (8.5 VDC min, 18 VDC max); ITU-T standards: G.991.2
Diagnostics & Test
Self-diagnosis; local loopback; remote loopback
EMC Emissions
EN55022:1998 Class B; FCC Part 15 Class B
EMC Immunity, Power
Fault, and Lightning
EN55024:1998; EN61000-3-2; EN61000-3-3; Telstra 1563; K.21 (2004)
Enhanced
Electrical Safety
EN60950; AS/NZS 60950; UL60950 3rd ed.;
CSA C22.2 No. 60950 3rd ed.; IEC 60950 CB Scheme
Telecom
S043.2; G.991.2
Environmental
Operating Temp: 0
o
C to 50
o
C; Storage Temp: -20
o
C to 70
o
C
*Note:
No stacking should be done at 50
o
C. Up to three units can be stacked at room temperature.
Humidity: 95 percent noncondensing
Dimensions
9.3 inches W x 2.1 inches H x 6.1 inches D
Connectors
SHDSL Port: RJ-45; 135 ohms; TNV-3 rated
10/100BaseT Ethernet: RJ-45
Console Port: DB-9 female
Power Input: Kycon KPJ-3S snap & lock or equivalent
Table standoff cannot be used with this unit.