Figure 12. Provisioning Screen
Figure 13. Troubleshooting Display
CIRCUIT ID: 01/01/99 00:11:47
PROVISIONING
* DSX-1 LINE BUILDOUT = 399-533 FEET
* DSX-1/DS1 LINE CODE = B8ZS
* DSX-1/DS1 FRAMING = ESF
* NIU LOOPBACK = DISABLED
* LOOPBACK TIMEOUT = NONE
* DS1 TX LEVEL = 0 dB
* HTUC SHELF ALARM = DISABLED
* DS0 BLOCKING (XX = BLOCKED):
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
* Option not configurable from this terminal
The DS1 Output level can be configured using a strap
on the circuit board of the HTU-R. All other changes
must be made from the HTU-C in the central office.
“M” - to return to the main menu
CIRCUIT ID: 01/01/99 00:12:13
TROUBLESHOOTING DISPLAY
_____ _____ _____ _____
|HTU-C| |HRE 1| |HRE 2| |HTU-R|
| | | | | | | |
| | | | | | | |
--->| |<=1=>| |<=1=>| |<=1=>| |<--
| | | | | | | |
NET(DSX-1) | | | | | | | | CUST(DS1)
| | | | | | | |
<---| |<=2=>| |<=2=>| |<=2=>| |-->
| | | | | | | |
| | | | | | | |
|_____| |_____| |_____| |_____|
NO ALARM CONDITIONS
Press “M” to return to the Main Menu